CoChat

A multicentre validation of the 1-min sit-to-stand test in patients with COPD

Open access
Crook, Sarah, Büsching, Gilbert, Schultz, Konrad, Lehbert, Nicola, Jelusic, Danijel, Keusch, Stephan, Wittmann, Michael, Schuler, Michael, Radtke, Thomas, Frey, Martin, Turk, Alexander, Puhan, Milo A., Frei, Anja · 2017 · European Respiratory Journal
Cited by 218

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Our aim was to comprehensively validate the 1-min sit-to-stand (STS) test in chronic obstructive pulmonary disease (COPD) patients and explore the physiological response to the test. We used data from two longitudinal studies of COPD patients who completed inpatient pulmonary rehabilitation programmes. We collected 1-min STS test, 6-min walk test (6MWT), health-related quality of life, dyspnoea and exercise cardiorespiratory data at admission and discharge. We assessed the learning effect, test–retest reliability, construct validity, responsiveness and minimal important difference of the 1-min STS test. In both studies (n=52 and n=203) the 1-min STS test was strongly correlated with the 6MWT at admission (r=0.59 and 0.64, respectively) and discharge (r=0.67 and 0.68, respectively). Intraclass correlation coefficients (95% CI) between 1-min STS tests were 0.93 (0.83–0.97) for learning effect and 0.99 (0.97–1.00) for reliability. Standardised response means (95% CI) were 0.87 (0.58–1.16) and 0.91 (0.78–1.07). The estimated minimal important difference was three repetitions. End-exercise oxygen consumption, carbon dioxide output, ventilation, breathing frequency and heart rate were similar in the 1-min STS test and 6MWT. The 1-min STS test is a reliable, valid and responsive test for measuring functional exercise capacity in COPD patients and elicited a physiological response comparable to that of the 6MWT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/13993003.01871-2016

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Metadata

Authors
Crook, S., Büsching, G., Schultz, K., Lehbert, N., Jelusic, D., Keusch, S., Wittmann, M., Schuler, M., Radtke, T., Frey, M., Turk, A., Puhan, M. A., & Frei, A.
Venue
European Respiratory Journal
Published
2017-03
Volume
49
Issue
3
Pages
1601871
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2592908009
Cited by
218
References
3
FWCI
9.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A multicentre validation of the 1-min sit-to-stand test in patients with COPD. https://app.cochat.ai/papers/10.1183/13993003.01871-2016
The paper
Crook, S., Büsching, G., Schultz, K., Lehbert, N., Jelusic, D., Keusch, S., Wittmann, M., Schuler, M., Radtke, T., Frey, M., Turk, A., Puhan, M. A., & Frei, A. (2017). A multicentre validation of the 1-min sit-to-stand test in patients with COPD. European Respiratory Journal. https://doi.org/10.1183/13993003.01871-2016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.