The DOI matches its Crossref record.
Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with self-collected nasal swab versus professional-collected nasopharyngeal swab
Open accessAbstract
Abstract Background Nasopharyngeal (NP) swab samples for antigen-detecting rapid diagnostic tests (Ag-RDTs) require qualified healthcare professionals and are frequently perceived as uncomfortable by patients. Methods We performed a manufacturer-independent, prospective diagnostic accuracy study, comparing professional-collected nasal mid-turbinate (NMT) to nasopharyngeal swab, using the test kits of a WHO-listed SARS-CoV-2 Ag-RDT (STANDARD Q COVID-19 Ag Test, SD Biosensor), which is also being distributed by Roche. Individuals with high suspicion for COVID-19 infection were tested. The reference standard was RT-PCR using a combined oro-/nasopharyngeal swab sample. Percent positive and negative agreement, as well as sensitivity and specificity were calculated. Results Among the 179 participants, 41 (22.9%) tested positive for SARS-CoV-2 by RT-PCR. The positive percent agreement of the two different sampling techniques for the Ag-RDT was 93.5% (CI 79.3-98.2). The negative percent agreement was 95.9% (CI 91.4-98.1). The Ag-RDT with NMT-sampling showed a sensitivity of 80.5% (33/41 PCR positives detected; CI 66.0-89.8) and specificity of 98.6% (CI 94.9-99.6) compared to RT-PCR. The sensitivity with NP-sampling was 73.2% (30/41 PCR positives detected; CI 58.1-84.3) and specificity was 99.3% (CI 96.0-100). In patients with high viral load (>7.0 log 10 SARS-CoV-2 RNA copies/swab), the sensitivity of the Ag-RDT with NMT-sampling was 100% and 94.7% with NP-sampling. Conclusion This study demonstrates that sensitivity of a WHO-listed SARS-CoV-2 Ag-RDT using a professional nasal-sampling kit is at least equal to that of the NP-sampling kit, although confidence intervals overlap. Of note, differences in the IFUs of the test procedures could have contributed to different sensitivities. NMT-sampling can be performed with less training, reduces patient discomfort, and it enables scaling of antigen testing strategies. Additional studies of patient self-sampling should be considered to further facilitate the scaling-up of Ag-RDT testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SARS-CoV-2 viral load and shedding kinetics
Puhach, O., Meyer, B., & Eckerle, I. (2022) · Nature Reviews Microbiology · doi:10.1038/s41579-022-00822-w · Cited by 424
Corman, V. M., Haage, V. C., Bleicker, T., Schmidt, M. L., Mühlemann, B., Zuchowski, M., Jo, W. K., Tscheak, P., Möncke-Buchner, E., Müller, M. A., et al. (2021) · The Lancet Microbe · doi:10.1016/s2666-5247(21)00056-2 · Cited by 340
Self-citationBrümmer, L. E., Katzenschlager, S., Gaeddert, M., Erdmann, C., Schmitz, S., Bota, M., Grilli, M., Larmann, J., Weigand, M. A., Pollock, N. R., et al. (2021) · PLOS Medicine · doi:10.1371/journal.pmed.1003735 · Cited by 298
Self-citationLee, R. A., Herigon, J. C., Benedetti, A., Pollock, N. R., & Denkinger, C. M. (2021) · Journal of Clinical Microbiology · doi:10.1128/jcm.02881-20 · Cited by 297
Self-citationSchuit, E., Venekamp, R. P., Hooft, L., Veldhuijzen, I. K., van den Bijllaardt, W., Pas, S. D., Zwart, V. F., Lodder, E. B., Hellwich, M., Koppelman, M., et al. (2022) · BMJ · doi:10.1136/bmj-2022-071215 · Cited by 41
Metadata
- Authors
- Lindner, A. K., Nikolai, O., Kausch, F., Wintel, M., Hommes, F., Gertler, M., Krüger, L. J., Gaeddert, M., Tobian, F., Lainati, F., Köppel, L., Seybold, J., Corman, V. M., Drosten, C., Hofmann, J., Sacks, J. A., Mockenhaupt, F. P., & Denkinger, C. M.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2020-12-10
- Volume
- 57
- Issue
- 4
- Pages
- 2003961
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W3112440110
- Cited by
- 167
- References
- 0
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with self-collected nasal swab versus professional-collected nasopharyngeal swab. https://app.cochat.ai/papers/10.1183/13993003.03961-2020
- The paper
- Lindner, A. K., Nikolai, O., Kausch, F., Wintel, M., Hommes, F., Gertler, M., Krüger, L. J., Gaeddert, M., Tobian, F., Lainati, F., Köppel, L., Seybold, J., Corman, V. M., Drosten, C., Hofmann, J., Sacks, J. A., Mockenhaupt, F. P., & Denkinger, C. M. (2021). Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with self-collected nasal swab versus professional-collected nasopharyngeal swab. European Respiratory Journal. https://doi.org/10.1183/13993003.03961-2020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.