CoChat

Randomized trial comparing polymer-coated extended-release morphine sulfate to controlled-release oxycodone HCl in moderate to severe nonmalignant pain

Nicholson, Bruce, Ross, Edgar, Sasaki, John, Weil, Arnold · 2006 · Current Medical Research and Opinion
Cited by 44

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess the long-term efficacy, tolerability and safety of polymer-coated extended-release morphine sulfate (P-ERMS) (KADIAN) compared with controlled-release oxycodone HCl (CRO) (OxyContin) in treating chronic, nonmalignant, moderate to severe pain in a community-based outpatient population. DESIGN: Phase IV, prospective, randomized, open-label. PARTICIPANTS: Adults (N = 112) with chronic, nonmalignant, moderate to severe pain with visual numeric scale (VNS) scores > or = 4 (0 = no pain; 10 = worst pain). INTERVENTIONS: Patients were randomized to receive either P-ERMS once-daily (QD) dosing or CRO twice-daily (BID) dosing for a 24-week treatment period. Upward titration of dose and switching P-ERMS to BID or CRO to thrice-daily (TID) dosing was allowed Weeks 2-24. MAIN OUTCOME MEASURES: Quality of life (Physical [PCS] and Mental [MCS] Component Summary scores of the SF-36v2 Health Survey), pain and sleep scores (0-10), and patient and clinician assessments of current therapy (-4 to +4). RESULTS: Patients in both treatment groups experienced significant improvements in PCS scores (P-ERMS, +2.6; CRO, +3.1; p < 0.05 vs. baseline); patients taking CRO also demonstrated improvements in MCS scores (+4.7, p < 0.05 vs. baseline). Both groups attained significant reductions from baseline to 24 weeks in pain (P-ERMS, -2.0; CRO, -1.4; p < or = 0.001 vs. baseline); the reduction with P-ERMS was clinically meaningful (as defined by at least a 2-point reduction in VNS score). Patients attained significant improvement in sleep scores (P-ERMS, -2.6; CRO, -1.6; p < 0.001 vs. baseline; p < 0.05, P-ERMS vs. CRO). At Week 24, both groups indicated significantly increased patient (P-ERMS, +2.6; CRO, +1.7; p < 0.001 vs. baseline) and clinician (P-ERMS, +4.0; CRO, +3.1; p < 0.001 vs. baseline) global assessments of therapy. After 24 weeks, all patients on P-ERMS were dosing within the FDA-approved frequencies (65% QD, 35% BID); 56% of patients on CRO dosed BID, but 38% dosed TID and 6% dosed four times daily (QID). Most common adverse events were constipation, nausea, and somnolence, with no significant difference between treatment groups. CONCLUSIONS: P-ERMS and CRO both relieved chronic nonmalignant pain in this community-based population; however, patients taking P-ERMS dosed in accordance with FDA-approved frequencies (QD/BID); 44% of those taking CRO dosed more frequently (TID/QID).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1185/030079906x115603

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 44

Metadata

Authors
Nicholson, B., Ross, E., Sasaki, J., & Weil, A.
Venue
Current Medical Research and Opinion
Published
2006-06-27
Volume
22
Issue
8
Pages
1503-1514
ISSN
  • 0300-7995 (ISSN-L)
  • 1473-4877
OpenAlex
W2028178196
Cited by
44
References
4
FWCI
3.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized trial comparing polymer-coated extended-release morphine sulfate to controlled-release oxycodone HCl in moderate to severe nonmalignant pain. https://app.cochat.ai/papers/10.1185/030079906x115603
The paper
Nicholson, B., Ross, E., Sasaki, J., & Weil, A. (2006). Randomized trial comparing polymer-coated extended-release morphine sulfate to controlled-release oxycodone HCl in moderate to severe nonmalignant pain. Current Medical Research and Opinion. https://doi.org/10.1185/030079906x115603

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.