The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A comparison of intranasal fentanyl spray with oral transmucosal fentanyl citrate for the treatment of breakthrough cancer pain: an open-label, randomised, crossover trial
Abstract
OBJECTIVE: The efficacy of intranasal fentanyl spray (INFS) was compared with that of oral transmucosal fentanyl citrate (OTFC) for the relief of cancer-related breakthrough pain (BTP) in an open-label, crossover trial. METHODS: Adult cancer patients receiving stable background opioid treatment and experiencing BTP episodes were recruited from 44 study centres in seven European countries (Austria, France, Germany, Italy, Poland, Spain and the United Kingdom); of the 196 patients enrolled, 139 were randomised to receive INFS followed by OTFC, or vice versa. Patients were titrated to an effective dose of one agent (50, 100 or 200 microg INFS; 200, 400, 600, 800, 1200 or 1600 microg OTFC) to treat six BTP episodes, then titration and treatment were repeated with the other agent. The primary outcome was patient-recorded time to onset of 'meaningful' pain relief. Secondary outcomes included pain intensity difference (PID) at 10 and 30 minutes (PID(10), PID(30)), sum of PID at 15 and 60 minutes (SPID(0-15), SPID(0-60)), ease of administration, treatment preference and relationship between background opioid dose and effective INFS dose. Additional outcome measures included proportions of episodes with > or =33% and > or =50% pain intensity (PI) reduction, and PID at additional time points. CLINICAL TRIAL REGISTRATION NUMBER: NCT00496392. RESULTS: Among the intention-to-treat population (n = 139), median time to onset of 'meaningful' pain relief was 11 minutes with INFS versus 16 minutes with OTFC; 65.7% of patients attained faster time to 'meaningful' pain-relief onset with INFS (p < 0.001). PID was statistically significantly greater for INFS than OTFC from 5 minutes post-dosing. Significantly more INFS-treated breakthrough pain episodes achieved clinically important pain relief (> or =33% and > or =50% PI reduction) up to 30 minutes post-dosing. The proportions of episodes treated with INFS and OTFC achieving a PI reduction of > or =33% at 5 minutes were 25.3% versus 6.8% (p < 0.001), and at 10 minutes were 51.0% versus 23.6% (p < 0.001), respectively; the proportions of episodes treated with INFS and OTFC achieving a > or =50% PI reduction at 5 minutes were 12.8% versus 2.1% (p < 0.001), and at 10 minutes were 36.9% versus 9.7% (p < 0.001), respectively. Higher SPID(0-15) and SPID(0-60) scores were achieved with INFS (p < 0.001). More patients preferred INFS than OTFC (p < 0.001) and more patients found it very easy/easy to use. Both treatments were well tolerated. In the safety population (n = 139), 56.8% (n = 79) of patients experienced > or =1 AE during the trial. The only AE that occurred in > or =5% of patients in either treatment group was nausea. Among those patients who experienced serious AEs (13.7%, n = 19), none were considered to be related to either study medication. There was a weak correlation between effective INFS doses and background opioid doses. CONCLUSION: In this open-label, randomised, crossover trial, significantly more patients attained faster 'meaningful' pain relief with INFS than OTFC, and more patients preferred INFS to OTFC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Cited by
Caraceni, A., Hanks, G., Kaasa, S., Bennett, M. I., Brunelli, C., Cherny, N., Dale, O., De Conno, F., Fallon, M., Hanna, M., et al. (2012) · The Lancet Oncology · doi:10.1016/s1470-2045(12)70040-2 · Cited by 1,243
Self-citationIntranasal drug delivery: An efficient and non-invasive route for systemic administration
Grassin-Delyle, S., Buenestado, A., Naline, E., Faisy, C., Blouquit-Laye, S., Couderc, L.-J., Le Guen, M., Fischler, M., & Devillier, P. (2012) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2012.03.003 · Cited by 398
Management of cancer pain: ESMO Clinical Practice Guidelines
Ripamonti, C. I., Santini, D., Maranzano, E., Berti, M., & Roila, F. (2012) · Annals of Oncology · doi:10.1093/annonc/mds233 · Cited by 329
Cannabinoid Delivery Systems for Pain and Inflammation Treatment
Bruni, N., Della Pepa, C., Oliaro-Bosso, S., Pessione, E., Gastaldi, D., & Dosio, F. (2018) · Molecules · doi:10.3390/molecules23102478 · Cited by 272
Metadata
- Authors
- Mercadante, S., Radbruch, L., Davies, A., Poulain, P., Sitte, T., Perkins, P., Colberg, T., & Camba, M. A.
- Venue
- Current Medical Research and Opinion
- Publisher
- Informa Healthcare
- Published
- 2009-09-30
- Volume
- 25
- Issue
- 11
- Pages
- 2805-2815
- ISSN
- 0300-7995 (ISSN-L)
- 1473-4877
- OpenAlex
- W2135516229
- Cited by
- 162
- References
- 1
- FWCI
- 23.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.