HTQC: a fast quality control toolkit for Illumina sequencing data
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Illumina sequencing platform is widely used in genome research. Sequence reads quality assessment and control are needed for downstream analysis. However, software that provides efficient quality assessment and versatile filtration methods is still lacking. Results: We have developed a toolkit named HTQC - abbreviation of High-Throughput Quality Control - for sequence reads quality control, which consists of six programs for reads quality assessment, reads filtration and generation of graphic reports. Conclusions: The HTQC toolkit can generate reads quality assessment faster than existing tools, providing guidance for reads filtration utilities that allow users to choose different strategies to remove low quality reads.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequencing technologies – the next generation
Metzker, M. L. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2626 · Cited by 7,066 · cited 1×
“Next generation sequencing technologies are generating massive sequence data [1], and different platforms can introduce varied level of sequence reads error.”
BackgroundSolexaQA: at-a-glance quality assessment of Illumina second-generation sequencing data
Cox, M. P., Peterson, D. A., & Biggs, P. J. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-485 · Cited by 1,357 · cited 2×
“Furthermore, many of these software tools are implemented using Perl language [3,5,6], which as a dynamic-typed script language, provides ease on developing mini programs, but causes severe loss on run-time performance [7].”
BackgroundMethodSubstantial biases in ultra-short read data sets from high-throughput DNA sequencing
Dohm, J. C., Lottaz, C., Borodina, T., & Himmelbauer, H. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn425 · Cited by 1,088 · cited 1×
“However, due to the nature of the method, it still presents a considerable amount of errors that has its specific errors pattern [2].”
Background
Cited by
Chen, Y., Chen, Y., Shi, C., Huang, Z., Zhang, Y., Li, S., Li, Y., Ye, J., Yu, C., Li, Z., et al. (2018) · GigaScience · doi:10.1093/gigascience/gix120 · Cited by 2,447
KAT: a K-mer analysis toolkit to quality control NGS datasets and genome assemblies
Mapleson, D., Garcia Accinelli, G., Kettleborough, G., Wright, J., & Clavijo, B. J. (2017) · Bioinformatics · doi:10.1093/bioinformatics/btw663 · Cited by 538
Falco: high-speed FastQC emulation for quality control of sequencing data
de Sena Brandine, G., & Smith, A. D. (2019) · F1000Research · doi:10.12688/f1000research.21142.1 · Cited by 343
Falco: high-speed FastQC emulation for quality control of sequencing data
de Sena Brandine, G., & Smith, A. D. (2021) · F1000Research · doi:10.12688/f1000research.21142.2 · Cited by 342
Advanced Applications of RNA Sequencing and Challenges
Han, Y., Gao, S., Muegge, K., Zhang, W., & Zhou, B. (2015) · Bioinformatics and Biology Insights · doi:10.4137/bbi.s28991 · Cited by 281
Metadata
- Authors
- Yang, X., Liu, D., Liu, F., Wu, J., Zou, J., Xiao, X., Zhao, F., & Zhu, B.
- Venue
- BMC Bioinformatics
- Published
- 2013-01-31
- Volume
- 14
- Issue
- 1
- Pages
- 33-33
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W1996543077
- Cited by
- 200
- References
- 3
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.