The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
TomoJ: tomography software for three-dimensional reconstruction in transmission electron microscopy
Open accessAbstract
Background: Transmission electron tomography is an increasingly common three-dimensional electron microscopy approach that can provide new insights into the structure of subcellular components. Transmission electron tomography fills the gap between high resolution structural methods (X-ray diffraction or nuclear magnetic resonance) and optical microscopy. We developed new software for transmission electron tomography, TomoJ. TomoJ is a plug-in for the now standard image analysis and processing software for optical microscopy, ImageJ. Results: TomoJ provides a user-friendly interface for alignment, reconstruction, and combination of multiple tomographic volumes and includes the most recent algorithms for volume reconstructions used in three-dimensional electron microscopy (the algebraic reconstruction technique and simultaneous iterative reconstruction technique) as well as the commonly used approach of weighted back-projection. Conclusion: The software presented in this work is specifically designed for electron tomography. It has been written in Java as a plug-in for ImageJ and is distributed as freeware.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UCSF Chimera—A visualization system for exploratory research and analysis
Pettersen, E. F., Goddard, T. D., Huang, C. C., Couch, G. S., Greenblatt, D. M., Meng, E. C., & Ferrin, T. E. (2004) · Journal of Computational Chemistry · doi:10.1002/jcc.20084 · Cited by 45,828
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
Abràmoff, M. D., Magalhães, P. J., & Ram, S. J. (2004) · Utrecht University Repository (Utrecht University) · Cited by 15,117
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Hahn, G. J., Draper, N., & Smith, H. (1982) · Technometrics · doi:10.2307/1267833 · Cited by 5,773
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
EMAN2: An extensible image processing suite for electron microscopy
Tang, G., Peng, L., Baldwin, P. R., Mann, D. S., Jiang, W., Rees, I., & Ludtke, S. J. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.05.009 · Cited by 2,994
SPIDER and WEB: Processing and Visualization of Images in 3D Electron Microscopy and Related Fields
Frank, J., Radermacher, M., Penczek, P., Zhu, J., Li, Y., Ladjadj, M., & Leith, A. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0030 · Cited by 2,027
Principles of Computerized Tomographic Imaging
Kak, A. C., Slaney, M., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1455742 · Cited by 1,877
Iterative methods for the three-dimensional reconstruction of an object from projections
Gilbert, P. (1972) · Journal of Theoretical Biology · doi:10.1016/0022-5193(72)90180-4 · Cited by 1,421
Cited by
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography
van Aarle, W., Palenstijn, W. J., De Beenhouwer, J., Altantzis, T., Bals, S., Batenburg, K. J., & Sijbers, J. (2015) · Ultramicroscopy · doi:10.1016/j.ultramic.2015.05.002 · Cited by 973
A high-level 3D visualization API for Java and ImageJ
Schmid, B., Schindelin, J., Cardona, A., Longair, M., & Heisenberg, M. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-274 · Cited by 551
A druggable copper-signalling pathway that drives inflammation
Solier, S., Müller, S., Cañeque, T., Versini, A., Mansart, A., Sindikubwabo, F., Baron, L., Emam, L., Gestraud, P., Pantoș, G. D., et al. (2023) · Nature · doi:10.1038/s41586-023-06017-4 · Cited by 330
Liu, Y., Meirer, F., Williams, P. A., Wang, J., Andrews, J. C., & Pianetta, P. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511049144 · Cited by 278
Goodarzi, S., Prunet, A., Rossetti, F., Bort, G., Tillement, O., Porcel, E., Lacombe, S., Wu, T.-D., Guerquin-Kern, J.-L., Delanoë-Ayari, H., et al. (2021) · Lab on a Chip · doi:10.1039/d1lc00192b · Cited by 29
Metadata
- Authors
- MessaoudiI, C., Boudier, T., Sorzano, C. O. S., & Marco, S.
- Venue
- BMC Bioinformatics
- Published
- 2007-08-06
- Volume
- 8
- Issue
- 1
- Pages
- 288-288
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W1993161289
- Cited by
- 317
- References
- 38
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: TomoJ: tomography software for three-dimensional reconstruction in transmission electron microscopy. https://app.cochat.ai/papers/10.1186/1471-2105-8-288
- The paper
- MessaoudiI, C., Boudier, T., Sorzano, C. O. S., & Marco, S. (2007). TomoJ: tomography software for three-dimensional reconstruction in transmission electron microscopy. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-8-288
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.