CoChat

A comparison of Affymetrix gene expression arrays

Open access
Robinson, Mark D, Speed, Terence P · 2007 · BMC Bioinformatics
Cited by 68

The DOI matches its Crossref record.

Abstract

BACKGROUND: Affymetrix GeneChips are an important tool in many facets of biological research. Recently, notable design changes to the chips have been made. In this study, we use publicly available data from Affymetrix to gauge the performance of three human gene expression arrays: Human Genome U133 Plus 2.0 (U133), Human Exon 1.0 ST (HuEx) and Human Gene 1.0 ST (HuGene). RESULTS: We studied probe-, exon- and gene-level reproducibility of technical and biological replicates from each of the 3 platforms. The U133 array has larger feature sizes so it is no surprise that probe-level variances are smaller, however the larger number of probes per gene on the HuGene array seems to produce gene-level summaries that have similar variances. The gene-level summaries of the HuEx array are less reproducible than the other two, despite having the largest average number of probes per gene. Greater than 80% of the content on the HuEx arrays is expressed at or near background. Biological variation seems to have a smaller effect on U133 data. Comparing the overlap of differentially expressed genes, we see a high overall concordance among all 3 platforms, with HuEx and HuGene having greater overlap, as expected given their design. We performed an analysis of detection rates and area under ROC curves using an experiment made up of several mixtures of 2 human tissues. Though it appears that the HuEx array has worse performance in terms of detection rates, all arrays have similar ability to separate differentially expressed and non-differentially expressed genes. CONCLUSION: Despite noticeable differences in the probe-level reproducibility, gene-level reproducibility and differential expression detection are quite similar across the three platforms. The HuEx array, an all-encompassing array, has the flexibility of measuring all known or predicted exonic content. However, the HuEx array induces poorer reproducibility for genes with fewer exons. The HuGene measures just the well-annotated genome content and appears to perform well. The U133 array, though not able to measure across the full length of a transcript, appears to perform as well as the newer designs on the set of genes common to all 3 platforms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2105-8-449

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 68

Metadata

Authors
Robinson, M. D., & Speed, T. P.
Venue
BMC Bioinformatics
Published
2007-11-15
Volume
8
Issue
1
Pages
449-449
ISSN
1471-2105 (ISSN-L)
OpenAlex
W2006425206
Cited by
68
References
0
FWCI
2.75
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of Affymetrix gene expression arrays. https://app.cochat.ai/papers/10.1186/1471-2105-8-449
The paper
Robinson, M. D., & Speed, T. P. (2007). A comparison of Affymetrix gene expression arrays. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-8-449

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.