The DOI matches its Crossref record.
Highly accurate sigmoidal fitting of real-time PCR data by introducing a parameter for asymmetry
Open accessAbstract
BACKGROUND: Fitting four-parameter sigmoidal models is one of the methods established in the analysis of quantitative real-time PCR (qPCR) data. We had observed that these models are not optimal in the fitting outcome due to the inherent constraint of symmetry around the point of inflection. Thus, we found it necessary to employ a mathematical algorithm that circumvents this problem and which utilizes an additional parameter for accommodating asymmetrical structures in sigmoidal qPCR data. RESULTS: The four-parameter models were compared to their five-parameter counterparts by means of nested F-tests based on the residual variance, thus acquiring a statistical measure for higher performance. For nearly all qPCR data we examined, five-parameter models resulted in a significantly better fit. Furthermore, accuracy and precision for the estimation of efficiencies and calculation of quantitative ratios were assessed with four independent dilution datasets and compared to the most commonly used quantification methods. It could be shown that the five-parameter model exhibits an accuracy and precision more similar to the non-sigmoidal quantification methods. CONCLUSION: The five-parameter sigmoidal models outperform the established four-parameter model with high statistical significance. The estimation of essential PCR parameters such as PCR efficiency, threshold cycles and initial template fluorescence is more robust and has smaller variance. The model is implemented in the qpcR package for the freely available statistical R environment. The package can be downloaded from the author's homepage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
Real-Time Quantitative RT-PCR: Design, Calculations, and Statistics
Rieu, I., & Powers, S. J. (2009) · The Plant Cell · doi:10.1105/tpc.109.066001 · Cited by 451
Robust Quantification of Polymerase Chain Reactions Using Global Fitting
Carr, A. C., & Moore, S. D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037640 · Cited by 297
Bustin, S. A., Ruijter, J. M., van den Hoff, M. J. B., Kubista, M., Pfaffl, M. W., Shipley, G. L., Tran, N., Rödiger, S., Untergasser, A., Mueller, R., et al. (2025) · Clinical Chemistry · doi:10.1093/clinchem/hvaf043 · Cited by 296
Ruijter, J. M., Pfaffl, M. W., Zhao, S., Spiess, A. N., Boggy, G., Blom, J., Rutledge, R. G., Sisti, D., Lievens, A., De Preter, K., et al. (2013) · Methods · doi:10.1016/j.ymeth.2012.08.011 · Cited by 258
Self-citation
Metadata
- Authors
- Spiess, A.-N., Feig, C., & Ritz, C.
- Venue
- BMC Bioinformatics
- Published
- 2008-04-29
- Volume
- 9
- Issue
- 1
- Pages
- 221-221
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2170994550
- Cited by
- 167
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly accurate sigmoidal fitting of real-time PCR data by introducing a parameter for asymmetry. https://app.cochat.ai/papers/10.1186/1471-2105-9-221
- The paper
- Spiess, A.-N., Feig, C., & Ritz, C. (2008). Highly accurate sigmoidal fitting of real-time PCR data by introducing a parameter for asymmetry. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-9-221
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.