Large scale real-time PCR validation on gene expression measurements from two commercial long-oligonucleotide microarrays
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background: DNA microarrays are rapidly becoming a fundamental tool in discovery-based genomic and biomedical research. However, the reliability of the microarray results is being challenged due to the existence of different technologies and non-standard methods of data analysis and interpretation. In the absence of a "gold standard"/"reference method" for the gene expression measurements, studies evaluating and comparing the performance of various microarray platforms have often yielded subjective and conflicting conclusions. To address this issue we have conducted a large scale TaqMan® Gene Expression Assay based real-time PCR experiment and used this data set as the reference to evaluate the performance of two representative commercial microarray platforms. Results: In this study, we analyzed the gene expression profiles of three human tissues: brain, lung, liver and one universal human reference sample (UHR) using two representative commercial long-oligonucleotide microarray platforms: (1) Applied Biosystems Human Genome Survey Microarrays (based on single-color detection); (2) Agilent Whole Human Genome Oligo Microarrays (based on two-color detection). 1,375 genes represented by both microarray platforms and spanning a wide dynamic range in gene expression levels, were selected for TaqMan® Gene Expression Assay based real-time PCR validation. For each platform, four technical replicates were performed on the same total RNA samples according to each manufacturer's standard protocols. For Agilent arrays, comparative hybridization was performed using incorporation of Cy5 for brain/lung/liver RNA and Cy3 for UHR RNA (common reference). Using the TaqMan® Gene Expression Assay based real-time PCR data set as the reference set, the performance of the two microarray platforms was evaluated focusing on the following criteria: (1) Sensitivity and accuracy in detection of expression; (2) Fold change correlation with real-time PCR data in pair-wise tissues as well as in gene expression profiles determined across all tissues; (3) Sensitivity and accuracy in detection of differential expression. Conclusion: Our study provides one of the largest "reference" data set of gene expression measurements using TaqMan® Gene Expression Assay based real-time PCR technology. This data set allowed us to use an alternative gene expression technology to evaluate the performance of different microarray platforms. We conclude that microarrays are indeed invaluable discovery tools with acceptable reliability for genome-wide gene expression screening, though validation of putative changes in gene expression remains advisable. Our study also characterizes the limitations of microarrays; understanding these limitations will enable researchers to more effectively evaluate microarray results in a more cautious and appropriate manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bolstad, B. M., Irizarry, R. A., Åstrand, M., & Speed, T. P. (2003) · Bioinformatics · doi:10.1093/bioinformatics/19.2.185 · Cited by 8,266
Huber, W., von Heydebreck, A., Sültmann, H., Poustka, A., & Vingron, M. (2002) · Bioinformatics · doi:10.1093/bioinformatics/18.suppl_1.s96 · Cited by 2,440
Normalization of cDNA microarray data
Smyth, G. K., & Speed, T. (2003) · Methods · doi:10.1016/s1046-2023(03)00155-5 · Cited by 1,871 · cited 1×
“Besides using the default global median normalization method, we also investigated several other normalization methods for the Applied Biosystems data set, including Quantile normalization [23], scale normalization [24] and Variance Stabilization Normalization (VSN) [25], using the limma and vsn packages of R/Biocondu…”
MethodReal-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
The real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
What's In A Name? Malay Seals As Onomastic Sources
Library, T. B., & Gallop, A. T. (2018) · Malay Literature · doi:10.37052/ml.31(1)no1 · Cited by 1,483
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Expression profiling using microarrays fabricated by an ink-jet oligonucleotide synthesizer
Hughes, T. R., Mao, M., Jones, A. R., Burchard, J., Marton, M. J., Shannon, K. W., Lefkowitz, S. M., Ziman, M., Schelter, J. M., Meyer, M. R., et al. (2001) · Nature Biotechnology · doi:10.1038/86730 · Cited by 1,298
Multiple-laboratory comparison of microarray platforms
Irizarry, R. A., Warren, D., Spencer, F., Kim, I. F., Biswal, S., Frank, B. C., Gabrielson, E., Garcia, J. G. N., Geoghegan, J., Germino, G., et al. (2005) · Nature Methods · doi:10.1038/nmeth756 · Cited by 862 · cited 1×
“However, in the absence of a "gold standard" or common reference for gene expression measurements, these evaluations and comparisons have often yield subjective and conflicting conclusions [5-11].”
BackgroundEvaluation of gene expression measurements from commercial microarray platforms
Tan, P. K. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg763 · Cited by 706
Cited by
Evaluation of DNA microarray results with quantitative gene expression platforms
Canales, R. D., Luo, Y., Willey, J. C., Austermiller, B., Barbacioru, C. C., Boysen, C., Hunkapiller, K., Jensen, R. V., Knight, C. R., Lee, K. Y., et al. (2006) · Nature Biotechnology · doi:10.1038/nbt1236 · Cited by 615
Self-citationPatterson, T. A., Lobenhofer, E. K., Fulmer-Smentek, S. B., Collins, P. J., Chu, T.-M., Bao, W., Fang, H., Kawasaki, E. S., Hager, J., Tikhonova, I. R., et al. (2006) · Nature Biotechnology · doi:10.1038/nbt1242 · Cited by 492
Self-citationDESALVO, M. K., VOOLSTRA, C. R., SUNAGAWA, S., SCHWARZ, J. A., STILLMAN, J. H., COFFROTH, M. A., SZMANT, A. M., & MEDINA, M. (2008) · Molecular Ecology · doi:10.1111/j.1365-294x.2008.03879.x · Cited by 414
Shi, L., Jones, W. D., Jensen, R. V., Harris, S. C., Perkins, R. G., Goodsaid, F. M., Guo, L., Croner, L. J., Boysen, C., Fang, H., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-s9-s10 · Cited by 401
Self-citationOntology-Based Meta-Analysis of Global Collections of High-Throughput Public Data
Kupershmidt, I., Su, Q. J., Grewal, A., Sundaresh, S., Halperin, I., Flynn, J., Shekar, M., Wang, H., Park, J., Cui, W., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013066 · Cited by 368
Caldana, C., Scheible, W.-R., Mueller-Roeber, B., & Ruzicic, S. (2007) · Plant Methods · doi:10.1186/1746-4811-3-7 · Cited by 246
“In contrast, CV values are generally higher in microarray-based analyses of genes with such low expression, indicating a lower reproducibility [ 25 ].”
BackgroundSaulnier, D. M. A., Molenaar, D., de Vos, W. M., Gibson, G. R., & Kolida, S. (2007) · Applied and Environmental Microbiology · doi:10.1128/aem.01151-06 · Cited by 241
“Recent comparisons between microarrays from Agilent platforms and quantitative PCR have also shown a good correlation for genome-wide studies (45).”
BackgroundMilagro, F. I., Campión, J., Cordero, P., Goyenechea, E., GGómez‐Uriz, A. M., Abete, I., Zulet, M. A., & Martínez, J. A. (2011) · The FASEB Journal · doi:10.1096/fj.10-170365 · Cited by 236
“In this sense, admitting that methylation microarray generates a high number of false positives, array technology is a useful tool for screening genome-wide DNA methylation status, although with limitations that researchers have to evaluate in a cautious and appropriate manner (35).”
Rutledge, R. G., & Stewart, D. (2008) · BMC Biotechnology · doi:10.1186/1472-6750-8-47 · Cited by 209
“Historically, real-time qPCR has largely been relegated to a supportive role in large-scale gene expression studies, most frequently used for the verification of DNA microarray datasets [1-3].”
BackgroundHopwood, B., Tsykin, A., Findlay, D. M., & Fazzalari, N. L. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2301 · Cited by 188
“This probably reflects differences in sensitivity between the two techniques [55, 56 ].”
ResultEyileten, C., Wicik, Z., De Rosa, S., Mirowska-Guzel, D., Soplinska, A., Indolfi, C., Jastrzebska-Kurkowska, I., Czlonkowska, A., & Postula, M. (2018) · Cells · doi:10.3390/cells7120249 · Cited by 174
“limitation of microarray analysis compared to RT-qPCR analysis [65].”
MethodModularity and design principles in the sea urchin embryo gene regulatory network
Peter, I. S., & Davidson, E. H. (2009) · FEBS Letters · doi:10.1016/j.febslet.2009.11.060 · Cited by 89
“Commonly used array-based technologies to detect gene expression levels have a much lower sensitivity than PCR-based approaches [3], which limits their usefulness for identifying lowabundance regulatory gene transcripts.”
BackgroundDifferential gene expression in brain tissues of aggressive and non-aggressive dogs
Våge, J., Bønsdorff, T. B., Arnet, E., Tverdal, A., & Lingaas, F. (2010) · BMC Veterinary Research · doi:10.1186/1746-6148-6-34 · Cited by 35
Nrf2 Regulates Basal Glutathione Production in Astrocytes
He, J., & Hewett, S. J. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26020687 · Cited by 25
Metadata
- Authors
- Wang, Y., Barbacioru, C., Hyland, F., Xiao, W., Hunkapiller, K. L., Blake, J., Chan, F., Gonzalez, C., Zhang, L., & Samaha, R. R.
- Venue
- BMC Genomics
- Published
- 2006-03-21
- Volume
- 7
- Issue
- 1
- Pages
- 59-59
- ISSN
- 1471-2164 (ISSN-L)
- OpenAlex
- W1600272042
- Cited by
- 308
- References
- 23
- FWCI
- 14.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.