Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

A study of the diagnostic accuracy of the PHQ-9 in primary care elderly

Open access
Phelan, Elizabeth, Williams, Barbara, Meeker, Kathryn, Bonn, Katie, Frederick, John, LoGerfo, James, Snowden, Mark · 2010 · BMC Family Practice

Abstract

BACKGROUND: The diagnostic accuracy of the Patient Health Questionnaire-9 (PHQ-9) for assessment of depression in elderly persons in primary care settings in the United States has not been previously addressed. Thus, the purpose of this study was to evaluate the test performance of the PHQ-9 for detecting major and minor depression in elderly patients in primary care. METHODS: A prospective study of diagnostic accuracy was conducted in two primary care, university-based clinics in the Pacific Northwest of the United States. Seventy-one patients aged 65 years or older participated; all completed the PHQ-9 and the 15-item Geriatric Depression Scale (GDS) and underwent the Structured Clinical Interview for Depression (SCID). Sensitivity, specificity, area under the receiver operating characteristic (ROC) curve, and likelihood ratios (LRs) were calculated for the PHQ-9, the PHQ-2, and the 15-item GDS for major depression alone and the combination of major plus minor depression. RESULTS: Two thirds of participants were female, with a mean age of 78 and two chronic health conditions. Twelve percent met SCID criteria for major depression and 13% minor depression. The PHQ-9 had an area under the curve (AUC) of 0.87 (95% confidence interval [CI], 0.74-1.00) for major depression, while the PHQ-2 and the 15-item GDS each had an AUC of 0.81 (95% CI for PHQ-2, 0.64-0.98, and for 15-item GDS, 0.70-0.91; P = 0.551). For major and minor depression combined, the AUC for the PHQ-9 was 0.85 (95% CI, 0.73-0.96), for the PHQ-2, 0.80 (95% CI, 0.68-0.93), and for the 15-item GDS, 0.71 (95% CI, 0.55-0.87; P = 0.187). CONCLUSIONS: Based on AUC values, the PHQ-9 performs comparably to the PHQ-2 and the 15-item GDS in identifying depression among primary care elderly.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2296-11-63

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 196

Metadata

Authors
Phelan, E., Williams, B., Meeker, K., Bonn, K., Frederick, J., LoGerfo, J., & Snowden, M.
Venue
BMC Family Practice
Published
2010-09-01
Volume
11
Issue
1
Pages
63-63
ISSN
1471-2296 (ISSN-L)
OpenAlex
W2025888966
Cited by
196
References
19
FWCI
7.99
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A study of the diagnostic accuracy of the PHQ-9 in primary care elderly. https://app.cochat.ai/papers/10.1186/1471-2296-11-63
The paper
Phelan, E., Williams, B., Meeker, K., Bonn, K., Frederick, J., LoGerfo, J., & Snowden, M. (2010). A study of the diagnostic accuracy of the PHQ-9 in primary care elderly. BMC Family Practice. https://doi.org/10.1186/1471-2296-11-63

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.