CoChat

Comparison of ELF, FibroTest and FibroScan for the non-invasive assessment of liver fibrosis

Open access
Friedrich-Rust, Mireen, Rosenberg, William, Parkes, Julie, Herrmann, Eva, Zeuzem, Stefan, Sarrazin, Christoph · 2010 · BMC Gastroenterology
Cited by 140

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: FibroTest (FT) is the most frequently used serum fibrosis marker and consists of an algorithm of five fibrosis markers (alfa2-macroglobulin, apolipoproteinA1, haptoglobin, GGT, bilirubin). The Enhanced Liver Fibrosis (ELF) test consists of an algorithm of three fibrosis markers (hyaluronic acid, amino-terminal propeptide-of-type-III-collagen, tissue-inhibitor of matrix-metaloproteinase-1). While a systematic review has shown comparable results for both individual markers, there has been no direct comparison of both markers. Methods: In the present study, the ELF-test was analyzed retrospectively in patients with chronic liver disease, who received a liver biopsy, transient elastography (TE) and the FibroTest using histology as the reference method. Histology was classified according to METAVIR and the Ludwig's classification (F0-F4) for patients with chronic hepatitis C and B virus (HCV, HBV) infection and primary biliary cirrhosis (PBC), respectively. Results: Seventy-four patients were analysed: 36 with HCV, 10 with HBV, and 28 with PBC. The accuracy (AUROC) for the diagnosis of significant fibrosis (F≥2) for ELF and FibroTest was 0.78 (95%CI:0.67-0.89) and 0.69 (95%-CI:0.57-0.82), respectively (difference not statistically significant, n.s.). The AUROC for the diagnosis of liver cirrhosis was 0.92 (95%CI:0.83-1,00), and 0.91 (95%CI:0.83-0.99), respectively (n.s.). For 66 patients with reliable TE measurements the AUROC for the diagnosis of significant fibrosis (cirrhosis) for TE, ELF and FT were 0.80 (0.94), 0.76 (0.92), and 0.67 (0.91), respectively (n.s.). Conclusion: FibroTest and ELF can be performed with comparable diagnostic accuracy for the non-invasive staging of liver fibrosis. Serum tests are informative in a higher proportion of patients than transient elastography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-230x-10-103

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 140

Metadata

Authors
Friedrich-Rust, M., Rosenberg, W., Parkes, J., Herrmann, E., Zeuzem, S., & Sarrazin, C.
Venue
BMC Gastroenterology
Published
2010-09-09
Volume
10
Issue
1
Pages
103-103
ISSN
1471-230X (ISSN-L)
OpenAlex
W2134819112
Cited by
140
References
3
FWCI
8.39
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.