The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms
Open accessAbstract
Background: Environmental surfaces play an important role in transmission of healthcare-associated pathogens. There is a need for new disinfection methods that are effective against Clostridium difficile spores, but also safe, rapid, and automated. Methods: The Tru-D™ Rapid Room Disinfection device is a mobile, fully-automated room decontamination technology that utilizes ultraviolet-C irradiation to kill pathogens. We examined the efficacy of environmental disinfection using the Tru-D device in the laboratory and in rooms of hospitalized patients. Cultures for C. difficile, methicillin-resistant Staphylococcus aureus (MRSA), and vancomycin-resistant Enterococcus (VRE) were collected from commonly touched surfaces before and after use of Tru-D. Results: On inoculated surfaces, application of Tru-D at a reflected dose of 22,000 μWs/cm 2 for ~45 minutes consistently reduced recovery of C. difficile spores and MRSA by >2-3 log 10 colony forming units (CFU)/cm 2 and of VRE by >3-4 log 10 CFU/cm 2. Similar killing of MRSA and VRE was achieved in ~20 minutes at a reflected dose of 12,000 μWs/cm 2, but killing of C. difficile spores was reduced. Disinfection of hospital rooms with Tru-D reduced the frequency of positive MRSA and VRE cultures by 93% and of C. difficile cultures by 80%. After routine hospital cleaning of the rooms of MRSA carriers, 18% of sites under the edges of bedside tables (i.e., a frequently touched site not easily amenable to manual application of disinfectant) were contaminated with MRSA, versus 0% after Tru-D (P < 0.001). The system required <5 minutes to set up and did not require continuous monitoring. Conclusions: The Tru-D Rapid Room Disinfection device is a novel, automated, and efficient environmental disinfection technology that significantly reduces C. difficile, VRE and MRSA contamination on commonly touched hospital surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guideline for hand hygiene in health-care settings
Boyce, J. M., & Pittet, D. (2002) · American Journal of Infection Control · doi:10.1067/mic.2002.130391 · Cited by 2,120
Cited by
Tacconelli, E., Cataldo, M. A., Dancer, S. J., De Angelis, G., Falcone, M., Frank, U., Kahlmeter, G., Pan, A., Petrosillo, N., Rodríguez-Baño, J., et al. (2014) · Clinical Microbiology and Infection · doi:10.1111/1469-0691.12427 · Cited by 864
Dancer, S. J. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-14 · Cited by 679
Otter, J. A., Yezli, S., Salkeld, J. A. G., & French, G. L. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2012.12.004 · Cited by 594
Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals
Boyce, J. M. (2016) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-016-0111-x · Cited by 442
D’Accolti, M., Soffritti, I., Mazzacane, S., & Caselli, E. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20071535 · Cited by 82
Metadata
- Authors
- Nerandzic, M. M., Cadnum, J. L., Pultz, M. J., & Donskey, C. J.
- Venue
- BMC Infectious Diseases
- Published
- 2010-07-08
- Volume
- 10
- Issue
- 1
- Pages
- 197-197
- ISSN
- 1471-2334 (ISSN-L)
- OpenAlex
- W2123522802
- Cited by
- 241
- References
- 1
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. https://app.cochat.ai/papers/10.1186/1471-2334-10-197
- The paper
- Nerandzic, M. M., Cadnum, J. L., Pultz, M. J., & Donskey, C. J. (2010). Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infectious Diseases. https://doi.org/10.1186/1471-2334-10-197
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.