Clinical impact of a commercially available multiplex PCR system for rapid detection of pathogens in patients with presumed sepsis
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Timely identification of pathogens is crucial to minimize mortality in patients with severe infections. Detection of bacterial and fungal pathogens in blood by nucleic acid amplification promises to yield results faster than blood cultures (BC). We analyzed the clinical impact of a commercially available multiplex PCR system in patients with suspected sepsis. METHODS: Blood samples from patients with presumed sepsis were cultured with the Bactec 9240 system (Becton Dickinson, Heidelberg, Germany) and aliquots subjected to analysis with the LightCycler SeptiFast (SF) Test (Roche Diagnostics, Mannheim, Germany) at a tertiary care centre. For samples with PCR-detected pathogens, the actual impact on clinical management was determined by chart review. Furthermore a comparison between the time to a positive blood culture result and the SF result, based on a fictive assumption that it was done either on a once or twice daily basis, was made. RESULTS: Of 101 blood samples from 77 patients, 63 (62%) yielded concordant negative results, 14 (13%) concordant positive and 9 (9%) were BC positive only. In 14 (13%) samples pathogens were detected by SF only, resulting in adjustment of antibiotic therapy in 5 patients (7,7% of patients). In 3 samples a treatment adjustment would have been made earlier resulting in a total of 8 adjustments in all 101 samples (8%). CONCLUSION: The addition of multiplex PCR to conventional blood cultures had a relevant impact on clinical management for a subset of patients with presumed sepsis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kumar, A., Roberts, D., Wood, K. E., Light, B., Parrillo, J. E., Sharma, S., Suppes, R., Feinstein, D., Zanotti, S., Taiberg, L., et al. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000217961.75225.e9 · Cited by 6,109 · cited 1×
“The effect of shortening this time interval with the use of a PCR test has yet to be examined [11].”
Wisplinghoff, H., Bischoff, T., Tallent, S. M., Seifert, H., Wenzel, R. P., & Edmond, M. B. (2004) · Clinical Infectious Diseases · doi:10.1086/421946 · Cited by 4,496 · cited 1×
“Invasive fungal infections have an especially high mortality [4,12,13].”
Ibrahim, E. H., Sherman, G., Ward, S., Fraser, V. J., & Kollef, M. H. (2000) · Chest · doi:10.1378/chest.118.1.146 · Cited by 1,779
Pfaller, M. A., Jones, R. N., Doern, G. V., Sader, H. S., Hollis, R. J., Messer, S. A., & Group, F. T. S. P. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.7.1886-1889.1998 · Cited by 281
Cited by
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Better Tests, Better Care: Improved Diagnostics for Infectious Diseases
Caliendo, A. M., Gilbert, D. N., Ginocchio, C. C., Hanson, K. E., May, L., Quinn, T. C., Tenover, F. C., Alland, D., Blaschke, A. J., Bonomo, R. A., et al. (2013) · Clinical Infectious Diseases · doi:10.1093/cid/cit578 · Cited by 628
New Approaches to Sepsis: Molecular Diagnostics and Biomarkers
Reinhart, K., Bauer, M., Riedemann, N. C., & Hartog, C. S. (2012) · Clinical Microbiology Reviews · doi:10.1128/cmr.00016-12 · Cited by 533
A randomized, double-blind, placebo-controlled trial of TAK-242 for the treatment of severe sepsis*
Rice, T. W., Wheeler, A. P., Bernard, G. R., Vincent, J.-L., Angus, D. C., Aikawa, N., Demeyer, I., Sainati, S., Amlot, N., Cao, C., et al. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181e7c5c9 · Cited by 512
Current Epidemiology and Growing Resistance of Gram-Negative Pathogens
Livermore, D. M. (2012) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2012.27.2.128 · Cited by 417
Metadata
- Authors
- Dierkes, C., Ehrenstein, B., Siebig, S., Linde, H.-J., Reischl, U., & Salzberger, B.
- Venue
- BMC Infectious Diseases
- Published
- 2009-08-11
- Volume
- 9
- Issue
- 1
- Pages
- 126-126
- ISSN
- 1471-2334 (ISSN-L)
- OpenAlex
- W2095128234
- Cited by
- 147
- References
- 4
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical impact of a commercially available multiplex PCR system for rapid detection of pathogens in patients with presumed sepsis. https://app.cochat.ai/papers/10.1186/1471-2334-9-126
- The paper
- Dierkes, C., Ehrenstein, B., Siebig, S., Linde, H.-J., Reischl, U., & Salzberger, B. (2009). Clinical impact of a commercially available multiplex PCR system for rapid detection of pathogens in patients with presumed sepsis. BMC Infectious Diseases. https://doi.org/10.1186/1471-2334-9-126
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.