Direct susceptibility testing for multi drug resistant tuberculosis: A meta-analysis
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Background: One of the challenges facing the tuberculosis (TB) control programmes in resource-limited settings is lack of rapid techniques for detection of drug resistant TB, particularly multi drug resistant tuberculosis (MDR TB). Results obtained with the conventional indirect susceptibility testing methods come too late to influence a timely decision on patient management. More rapid tests directly applied on sputum samples are needed. This study compared the sensitivity, specificity and time to results of four direct drug susceptibility testing tests with the conventional indirect testing for detection of resistance to rifampicin and isoniazid in M. tuberculosis. The four direct tests included two in-house phenotypic assays – Nitrate Reductase Assay (NRA) and Microscopic Observation Drug Susceptibility (MODS), and two commercially available tests – Genotype® MTBDR and Genotype® MTBDR plus (Hain Life Sciences, Nehren, Germany). Methods: A literature review and meta-analysis of study reports was performed. The Meta-Disc software was used to analyse the reports and tests for sensitivity, specificity, and area under the summary receiver operating characteristic (sROC) curves. Heterogeneity in accuracy estimates was tested with the Spearman correlation coefficient and Chi-square. Results: Eighteen direct DST reports were analysed: NRA – 4, MODS- 6, Genotype MTBDR® – 3 and Genotype® MTBDR plus – 5. The pooled sensitivity and specificity for detection of resistance to rifampicin were 99% and 100% with NRA, 96% and 96% with MODS, 99% and 98% with Genotype® MTBDR, and 99% and 99% with the new Genotype® MTBDR plus, respectively. For isoniazid it was 94% and 100% for NRA, 92% and 96% for MODS, 71% and 100% for Genotype® MTBDR, and 96% and 100% with the Genotype® MTBDR plus, respectively. The area under the summary receiver operating characteristic (sROC) curves was in ranges of 0.98 to 1.00 for all the four tests. Molecular tests were completed in 1 – 2 days and also the phenotypic assays were much more rapid than conventional testing. Conclusion: Direct testing of rifampicin and isoniazid resistance in M. tuberculosis was found to be highly sensitive and specific, and allows prompt detection of MDR TB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
The Statistical Evaluation of Medical Tests for Classification and Prediction
Pepe, M. S. (2003) · doi:10.1093/oso/9780198509844.001.0001 · Cited by 2,198
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.4.603 · Cited by 1,944 · cited 1×
“The cure rate is much lower than for drug susceptible TB, only around 60% [3].”
BackgroundThe Statistical Evaluation of Medical Tests for Classification and Prediction
(2005) · Technometrics · doi:10.1198/tech.2005.s278 · Cited by 1,899
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“In a meta-analysis of diagnostic accuracy studies, factors such as study design, patient selection criteria, reference standard and blinding, may be related to overly optimistic estimates of diagnostic accuracy [25].”
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405 · cited 1×
“Variations caused by threshold/cut off effect are detected by a Spearman correlation coefficient between the logit of sensitivity and logit of 1-specificity with a significant pvalue [27,32,33].”
MethodThe STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124 · cited 3×
“Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Moher D, Rennie D, de Vet HC, Lijmer JG: The STARD statement for reporting studies of diagnostic accuracy: explanation and elaboration.”
MethodInfluentialGuidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753 · cited 2×
“At the Q* point, sensitivity is equal to specificity and the false positive rate is at the minimum [31].”
BackgroundProperties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
Walter, S. D. (2002) · Statistics in Medicine · doi:10.1002/sim.1099 · Cited by 672 · cited 1×
“This implies that heterogeneity in sensitivity and specificity due to chance, study design/population, and the way a study was conducted could have caused the variations in the latter tests [34,35].”
Result
Cited by
Gandhi, N. R., Nunn, P., Dheda, K., Schaaf, H. S., Zignol, M., van Soolingen, D., Jensen, P., & Bayona, J. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60410-2 · Cited by 1,018
Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries: Challenges and Opportunities
Parsons, L. M., Somoskövi, Á., Gutierrez, C., Lee, E., Paramasivan, C. N., Abimiku, A., Spector, S., Roscigno, G., & Nkengasong, J. (2011) · Clinical Microbiology Reviews · doi:10.1128/cmr.00059-10 · Cited by 540
Advances in the diagnosis of tuberculosis
LANGE, C., & MORI, T. (2010) · Respirology · doi:10.1111/j.1440-1843.2009.01692.x · Cited by 184
Metadata
- Authors
- Bwanga, F., Hoffner, S., Haile, M., & Joloba, M. L.
- Venue
- BMC Infectious Diseases
- Published
- 2009-05-20
- Volume
- 9
- Issue
- 1
- Pages
- 67-67
- ISSN
- 1471-2334 (ISSN-L)
- OpenAlex
- W2093766061
- Cited by
- 172
- References
- 34
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.