Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Fine-needle aspiration biopsy (FNAB) of the breast is a minimally invasive yet maximally diagnostic method. However, the clinical use of FNAB has been questioned. The purpose of our study was to establish the overall value of FNAC in the diagnosis of breast lesions. Methods: After a review and quality assessment of 46 studies, sensitivity, specificity and other measures of accuracy of FNAB for evaluating breast lesions were pooled using random-effects models. Summary receiver operating characteristic curves were used to summarize overall accuracy. The sensitivity and specificity for the studies data (included unsatisfactory samples) and underestimation rate of unsatisfactory samples were also calculated. Results: The summary estimates for FNAB in diagnosis of breast carcinoma were as follows (unsatisfactory samples was temporarily exluded): sensitivity, 0.927 (95% confidence interval [CI], 0.921 to 0.933); specificity, 0.948 (95% CI, 0.943 to 0.952); positive likelihood ratio, 25.72 (95% CI, 17.35 to 28.13); negative likelihood ratio, 0.08 (95% CI, 0.06 to 0.11); diagnostic odds ratio, 429.73 (95% CI, 241.75 to 763.87); The pooled sensitivity and specificity for 11 studies, which reported unsatisfactory samples (unsatisfactory samples was considered to be positive in this classification) were 0.920 (95% CI, 0.906 to 0.933) and 0.768 (95% CI, 0.751 to 0.784) respectively. The pooled proportion of unsatisfactory samples that were subsequently upgraded to various grade cancers was 27.5% (95% CI, 0.221 to 0.296). Conclusions: FNAB is an accurate biopsy for evaluating breast malignancy if rigorous criteria are used. With regard to unsatisfactory samples, futher invasive procedures are required in order to minimize the chance of a missed diagnosis of breast cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
The diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261 · cited 1×
“The DOR is a single indicator of test accuracy [77] that combines the data from sensitivity and specificity into a single number.”
BackgroundTriple assessment in the diagnosis of breast cancer in Kashmir
Jan, M., Mattoo, J. A., Salroo, N. A., & Ahangar, S. (2010) · Indian Journal of Surgery · doi:10.1007/s12262-010-0030-7 · Cited by 38
Cited by
van Enst, W. A., Ochodo, E., Scholten, R. J., Hooft, L., & Leeflang, M. M. (2014) · BMC Medical Research Methodology · doi:10.1186/1471-2288-14-70 · Cited by 429
Raman spectroscopy for cancer detection and cancer surgery guidance: translation to the clinics
Santos, I. P., Barroso, E. M., Bakker Schut, T. C., Caspers, P. J., van Lanschot, C. G. F., Choi, D.-H., van der Kamp, M. F., Smits, R. W. H., van Doorn, R., Verdijk, R. M., et al. (2017) · The Analyst · doi:10.1039/c7an00957g · Cited by 169
McHugh, K. E., Bird, P., & Sturgis, C. D. (2019) · Cytopathology · doi:10.1111/cyt.12696 · Cited by 21
Philipo, G. S., Vuhahula, E., Kimambo, A., Mmbaga, E. J., Van Loon, K., & Ng, D. L. (2021) · JCO Global Oncology · doi:10.1200/go.20.00279 · Cited by 14
“Fine-needle aspiration biopsy (FNAB) is a minimally invasive and cost-effective tissue sampling method that has been successfully deployed in resource-constrained settings, which confers high accuracy in diagnosing palpable breast masses.(19,20) Rapid on-site evaluation (ROSE) allows for immediate assessment of FNAB s…”
BackgroundRapid Onsite Evaluation for Specimen Adequacy and Triage of Breast Masses in a Low-Resource Setting
Kimambo, A. H., Vuhahula, E. A., Philipo, G. S., Mushi, B. P., Mmbaga, E. J., Van Loon, K., & Ng, D. L. (2024) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2022-0398-oa · Cited by 6
Metadata
- Authors
- Yu, Y.-H., Wei, W., & Liu, J.-L.
- Venue
- BMC Cancer
- Published
- 2012-01-25
- Volume
- 12
- Issue
- 1
- Pages
- 41-41
- ISSN
- 1471-2407 (ISSN-L)
- OpenAlex
- W2064092637
- Cited by
- 102
- References
- 3
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/1471-2407-12-41
- The paper
- Yu, Y.-H., Wei, W., & Liu, J.-L. (2012). Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis. BMC Cancer. https://doi.org/10.1186/1471-2407-12-41
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.