Long term outcome and quality of life after open incisional hernia repair - light versus heavy weight meshes
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Mesh repair of incisional hernia is superior to the conventional technique. From all available materials for open surgery polypropylene (PP) is the most widely used. Development resulted in meshes with larger pore size, decreased mesh surface and lower weight. The aim of this retrospective non randomized study was to compare the quality of life in the long term follow up (> 72 month) after incisional hernia repair with "light weight"(LW) and "heavy weight"(HW) PP meshes. METHODS: 12 patients who underwent midline open incisional hernia repair with a HW-PP mesh (Prolene® 109 g/m2 pore size 1.6 mm) between January 1996 and December 1997 were compared with 12 consecutive patients who underwent the same procedure with a LW-PP mesh (Vypro® 54 g/m2, pore size 4-5 mm) from January 1998. The standard technique was the sublay mesh-plasty with the retromuscular positioning of the mesh. The two groups were equal in BMI, age, gender and hernia size. Patients were routinely seen back in the clinic. RESULTS: In the long term run (mean follow up 112 ± 22 months) patients of the HW mesh group revealed no significant difference in the SF-36 Health Survey domains compared to the LW group (mean follow up 75 ± 16 months). CONCLUSIONS: In this study the health related quality of life based on the SF 36 survey after open incisional hernia repair with light or heavy weight meshes is not related to the mesh type in the long term follow up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alonso, J., Ferrer, M., Gandek, B., Ware, J. E., Aaronson, N. K., Mosconi, P., Rasmussen, N. K., Bullinger, M., Fukuhara, S., Kaasa, S., et al. (2004) · Quality of Life Research · doi:10.1023/b:qure.0000018472.46236.05 · Cited by 786 · cited 1×
“The SF 36 Health Survey has been translated in more than 50 languages and adjusted to the cultural variations [24,29].”
MethodBullinger, M. (1995) · Social Science & Medicine · doi:10.1016/0277-9536(95)00115-n · Cited by 763
The Argument for Lightweight Polypropylene Mesh in Hernia Repair
Cobb, W. S., Kercher, K. W., & Heniford, B. T. (2005) · Surgical Innovation · doi:10.1177/155335060501200109 · Cited by 364
Cited by
Colavita, P. D., Tsirline, V. B., Belyansky, I., Walters, A. L., Lincourt, A. E., Sing, R. F., & Heniford, B. T. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e3182734130 · Cited by 193
A systematic review of the surgical treatment of large incisional hernia
Deerenberg, E. B., Timmermans, L., Hogerzeil, D. P., Slieker, J. C., Eilers, P. H. C., Jeekel, J., & Lange, J. F. (2015) · Hernia · doi:10.1007/s10029-014-1321-x · Cited by 137
Rickert, A., Kienle, P., Kuthe, A., Baumann, P., Engemann, R., Kuhlgatz, J., von Frankenberg, M., Knaebel, H. P., & Büchler, M. W. (2012) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-012-1009-6 · Cited by 27
Metadata
- Authors
- Ladurner, R., Chiapponi, C., Linhuber, Q., & Mussack, T.
- Venue
- BMC Surgery
- Published
- 2011-09-14
- Volume
- 11
- Issue
- 1
- Pages
- 25-25
- ISSN
- 1471-2482 (ISSN-L)
- OpenAlex
- W2003372877
- Cited by
- 59
- References
- 3
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.