Large-scale cell production of stem cells for clinical application using the automated cell processing machine
Open accessThe DOI matches its Crossref record.
Abstract
Background: Cell-based regeneration therapies have great potential for application in new areas in clinical medicine, although some obstacles still remain to be overcome for a wide range of clinical applications. One major impediment is the difficulty in large-scale production of cells of interest with reproducibility. Current protocols of cell therapy require a time-consuming and laborious manual process. To solve this problem, we focused on the robotics of an automated and high-throughput cell culture system. Automated robotic cultivation of stem or progenitor cells in clinical trials has not been reported till date. The system AutoCulture® used in this study can automatically replace the culture medium, centrifuge cells, split cells, and take photographs for morphological assessment. We examined the feasibility of this system in a clinical setting. Results: We observed similar characteristics by both the culture methods in terms of the growth rate, gene expression profile, cell surface profile by fluorescence-activated cell sorting, surface glycan profile, and genomic DNA stability. These results indicate that AutoCulture® is a feasible method for the cultivation of human cells for regenerative medicine. Conclusions: An automated cell-processing machine will play important roles in cell therapy and have widespread use from application in multicenter trials to provision of off-the-shelf cell products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Long-term maintenance of human induced pluripotent stem cells by automated cell culture system
Konagaya, S., Ando, T., Yamauchi, T., Suemori, H., & Iwata, H. (2015) · Scientific Reports · doi:10.1038/srep16647 · Cited by 94
Crombie, D. E., Daniszewski, M., Liang, H. H., Kulkarni, T., Li, F., Lidgerwood, G. E., Conquest, A., Hernández, D., Hung, S. S., Gill, K. P., et al. (2017) · SLAS Discovery · doi:10.1177/2472555217696797 · Cited by 46
“As illustrated in Figure 1, on the workbench, from left to right, are a cabinet with medium bottle and pump (1) which can deliver medium to a LiHa medium refill trough contained within a Torrey Pines heater; three carriers for up to 24 × 50 mL Falcon tubes (2), a LiHa wash station (3), a carrier for 5 mL DiTis (4), a…”
BackgroundBoussaad, I., Cruciani, G., Bolognin, S., Antony, P., Dording, C. M., Kwon, Y.-J., Heutink, P., Fava, E., Schwamborn, J. C., & Krüger, R. (2021) · Scientific Reports · doi:10.1038/s41598-021-81129-3 · Cited by 42
“(1) Liquid handler Biomek NX Span-8 including the plate shaker Shaking Peltier ALP and a tilting station Amplius (AIG) 3D Tilting ALP, (2) Liquid handler Biomek FXP (96- and 384-pipetting head including active wash-station and a BioShake 3000, (3) Acoustic droplet ejector Labcyte Echo550, (4) High content imager Yokog…”
MethodAutomated hiPSC culture and sample preparation for 3D live cell microscopy
Coston, M. E., Gregor, B. W., Arakaki, J., Borensztejn, A., Do, T. P., Fuqua, M. A., Haupt, A., Hendershott, M. C., Leung, W., Mueller, I. A., et al. (2020) · doi:10.1101/2020.12.18.423371 · Cited by 6
Metadata
- Authors
- Kami, D., Watakabe, K., Yamazaki-Inoue, M., Minami, K., Kitani, T., Itakura, Y., Toyoda, M., Sakurai, T., Umezawa, A., & Gojo, S.
- Venue
- BMC Biotechnology
- Published
- 2013-11-15
- Volume
- 13
- Issue
- 1
- Pages
- 102-102
- ISSN
- 1472-6750 (ISSN-L)
- OpenAlex
- W2026387069
- Cited by
- 47
- References
- 0
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large-scale cell production of stem cells for clinical application using the automated cell processing machine. https://app.cochat.ai/papers/10.1186/1472-6750-13-102
- The paper
- Kami, D., Watakabe, K., Yamazaki-Inoue, M., Minami, K., Kitani, T., Itakura, Y., Toyoda, M., Sakurai, T., Umezawa, A., & Gojo, S. (2013). Large-scale cell production of stem cells for clinical application using the automated cell processing machine. BMC Biotechnology. https://doi.org/10.1186/1472-6750-13-102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.