The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantum dot imaging for embryonic stem cells
Open accessAbstract
Background: Semiconductor quantum dots (QDs) hold increasing potential for cellular imaging both in vitro and in vivo. In this report, we aimed to evaluate in vivo multiplex imaging of mouse embryonic stem (ES) cells labeled with Qtracker delivered quantum dots (QDs). Results: Murine embryonic stem (ES) cells were labeled with six different QDs using Qtracker. ES cell viability, proliferation, and differentiation were not adversely affected by QDs compared with non-labeled control cells (P = NS). Afterward, labeled ES cells were injected subcutaneously onto the backs of athymic nude mice. These labeled ES cells could be imaged with good contrast with one single excitation wavelength. With the same excitation wavelength, the signal intensity, defined as (total signal-background)/exposure time in millisecond was 11 ± 2 for cells labeled with QD 525, 12 ± 9 for QD 565, 176 ± 81 for QD 605, 176 ± 136 for QD 655, 167 ± 104 for QD 705, and 1,713 ± 482 for QD 800. Finally, we have shown that QD 800 offers greater fluorescent intensity than the other QDs tested. Conclusion: In summary, this is the first demonstration of in vivo multiplex imaging of mouse ES cells labeled QDs. Upon further improvements, QDs will have a greater potential for tracking stem cells within deep tissues. These results provide a promising tool for imaging stem cell therapy non-invasively in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cao, F., Lin, S., Xie, X., Ray, P., Patel, M., Zhang, X., Drukker, M., Dylla, S. J., Connolly, A. J., Chen, X., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.588954 · Cited by 493
Self-citation
Cited by
Zavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714
Self-citationZhou, J., Yang, Y., & Zhang, C.-Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00049 · Cited by 704
Self-citationMeta-analysis of cellular toxicity for cadmium-containing quantum dots
Oh, E., Liu, R., Nel, A., Gemill, K. B., Bilal, M., Cohen, Y., & Medintz, I. L. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.338 · Cited by 502
Nanoparticles and their applications in cell and molecular biology
Wang, E. C., & Wang, A. Z. (2014) · Integrative Biology · doi:10.1039/c3ib40165k · Cited by 415
Li, K., Qin, W., Ding, D., Tomczak, N., Geng, J., Liu, R., Liu, J., Zhang, X., Liu, H., Liu, B., et al. (2013) · Scientific Reports · doi:10.1038/srep01150 · Cited by 361
Metadata
- Authors
- Lin, S., Xie, X., Patel, M. R., Yang, Y.-H., Li, Z., Cao, F., Gheysens, O., Zhang, Y., Gambhir, S. S., Rao, J. H., & Wu, J. C.
- Venue
- BMC Biotechnology
- Published
- 2007-10-09
- Volume
- 7
- Issue
- 1
- Pages
- 67-67
- ISSN
- 1472-6750 (ISSN-L)
- OpenAlex
- W2132635365
- Cited by
- 179
- References
- 1
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantum dot imaging for embryonic stem cells. https://app.cochat.ai/papers/10.1186/1472-6750-7-67
- The paper
- Lin, S., Xie, X., Patel, M. R., Yang, Y.-H., Li, Z., Cao, F., Gheysens, O., Zhang, Y., Gambhir, S. S., Rao, J. H., & Wu, J. C. (2007). Quantum dot imaging for embryonic stem cells. BMC Biotechnology. https://doi.org/10.1186/1472-6750-7-67
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.