Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities. METHOD: EDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin). Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC) was used to determine the within subject variability of measured hemoglobin. RESULTS: Of 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p < 0.001). The Bland and Altman's limit of agreement was -0.389 - 0.644 g/dl with the mean difference being 0.127 (95% CI: 0.102-0.153) and a non-significant difference in variability between the two measurements (p = 0.843). After adjusting to assess the effect of other possible confounders such as sex, age and category of person, there was no significant difference in the hemoglobin determined by the HemoCue compared to Cyanmethemoglobin (coef = -0.127, 95% CI: -0.379 - 0.634). CONCLUSION: Hemoglobin determined by the HemoCue method is comparable to that determined by the other methods. The HemoCue photometer is therefore recommended for use as on-the-spot device for determining hemoglobin in resource poor setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Worldwide prevalence of anaemia 1993-2005: WHO global database on anaemia.
de Benoist, B., McLean, E., Egll, I., & Cogswell, M. E. (2008) · Cited by 1,543
Evaluation of "HemoCue," a new device for determining hemoglobin.
von Schenck, H., Falkensson, M., & Lundberg, B. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.3.526 · Cited by 258 · cited 4×
“These include the studies conducted by von Schenck et al [15], Van de Louw et al; among patients with gastrointestinal bleeding [16], Rippmann et al; among surgical patients [17], Bridges et al; on repeated measurement of one sample [7], Neville; within urban general practice [18], Rechner et al; among neonates [19],…”
MethodResultInfluentialEstimating the prevalence of anaemia: a comparison of three methods.
Sari, M., de Pee, S., Martini, E., Herman, S., Sugiatmi, S., Bloem, M. W., & Yip, R. (2001) · Europe PMC (PubMed Central) · Cited by 165
Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood
Morris, S. S., Ruel, M. T., Cohen, R. J., Dewey, K. G., de la Brière, B., & Hassan, M. N. (1999) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/69.6.1243 · Cited by 153 · cited 1×
“Hemoglobin (Hb) assessments are the most reliable indicator widely used to screen individuals for anaemia, to draw inferences about the iron status of populations and to evaluate responses to nutritional interventions [1].”
BackgroundValidation of hemoglobin estimation using hemocue
Bhaskaram, P., Balakrishna, N., Radhakrishna, K., & Krishnaswamy, K. (2003) · The Indian Journal of Pediatrics · doi:10.1007/bf02722739 · Cited by 84 · cited 5×
“In addition, it requires less blood (10 μL), is cost effective and a more accurate method [12,16,19] as well as having other properties as stated by Sari et al [4] and Sawant et al [26].”
BackgroundMethodResultInfluentialLardi, A. M., Hirst, C., Mortimer, A. J., & McCollum, C. N. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.00328.x · Cited by 82 · cited 3×
“patients [17], Bridges et al; on repeated measurement of one sample [7], Neville; within urban general practice [18], Rechner et al; among neonates [19], Lardi et al; among patients undergoing aortic surgery in the theatre [14], Sari et al; among Indonesian mothers [4] and Radtke et al; among blood donors [20].”
BackgroundMethodResultRadtke, H., Polat, G., Kalus, U. J., Salama, A., & Kiesewetter, H. (2005) · Transfusion and Apheresis Science · doi:10.1016/j.transci.2004.11.004 · Cited by 70 · cited 1×
“patients [17], Bridges et al; on repeated measurement of one sample [7], Neville; within urban general practice [18], Rechner et al; among neonates [19], Lardi et al; among patients undergoing aortic surgery in the theatre [14], Sari et al; among Indonesian mothers [4] and Radtke et al; among blood donors [20].”
BackgroundReliability of HemoCue in patients with gastrointestinal bleeding
de Louw, A. V., Lasserre, N., Drouhin, F., Thierry, S., Lécuyer, L., Caen, D., & Tenaillon, A. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0461-6 · Cited by 44 · cited 2×
“These include the studies conducted by von Schenck et al [15], Van de Louw et al; among patients with gastrointestinal bleeding [16], Rippmann et al; among surgical Table 1 Summary of subject categories in the various subgroups”
MethodJahr, J. S., Lurie, F., Driessen, B., et al. (2002) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03020522 · Cited by 36 · cited 3×
“In settings where a central laboratory is used for the purposes of testing and transfusion monitoring, the time loss for blood sample transportation create delays which may lead to the loss of lives[3,12].”
BackgroundZhou, X., Yan, H., Xing, Y., Dang, S., Zhuoma, B., & Wang, D. (2009) · BMC Public Health · doi:10.1186/1471-2458-9-228 · Cited by 31 · cited 1×
“Nevertheless, other studies such as that conducted by Zhou et al; among pregnant women in a higher altitude area of Tibet, China [21] and Bhaskaram et al; among apparently healthy children of 1-6 years [12] do not support the use of the HemoCue in their various study populations.”
Result
Cited by
Methods and analyzers for hemoglobin measurement in clinical laboratories and field settings
Whitehead, R. D., Mei, Z., Mapango, C., & Jefferds, M. E. D. (2019) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14124 · Cited by 188
Hemoglobin Point-of-Care Testing: The HemoCue System
Sanchis-Gomar, F., Cortell-Ballester, J., Pareja-Galeano, H., Banfi, G., & Lippi, G. (2013) · SLAS Technology · doi:10.1177/2211068212457560 · Cited by 158
“Compared Accuracy and Reproducibility Type of Sample Rechner et al.7 Coulter Max-M — + Arterial Paddle8 Coulter STKS — + Capillary, venous, arterial Gomez-Simon et al.11 Technicon H3 analyzer — + Venous Morris et al.9 Abbott Cell-Dyn 3500 B-Hemoglobin – + Capillary, venous Van de Louw et al.10 Cell counter Pentra 120…”
BackgroundMethodAlam, M. A., Richard, S. A., Fahim, S. M., Mahfuz, M., Nahar, B., Das, S., Shrestha, B., Koshy, B., Mduma, E., Seidman, J. C., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0227839 · Cited by 150
“Blood samples were collected to evaluate iron, zinc and vitamin A status and anemia at 7, 15 and 24 months [47].”
MethodSodde, F. M., Liga, A. D., Jabir, Y. N., Tamiru, D., & Kidane, R. (2023) · Health Science Reports · doi:10.1002/hsr2.1358 · Cited by 6
Metadata
- Authors
- Nkrumah, B., Nguah, S. B., Sarpong, N., Dekker, D., Idriss, A., May, J., & Adu-Sarkodie, Y.
- Venue
- BMC Clinical Pathology
- Published
- 2011-04-21
- Volume
- 11
- Issue
- 1
- Pages
- 5-5
- ISSN
- 1472-6890 (ISSN-L)
- OpenAlex
- W2111857067
- Cited by
- 173
- References
- 11
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.