The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Neonatal non-contact respiratory monitoring based on real-time infrared thermography
Open accessAbstract
BACKGROUND: Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring of neonatal vital signals based on infrared thermography as a new biomedical engineering application. One signal of clinical interest is the spontaneous respiration rate of the neonate. It will be shown that the respiration rate of neonates can be monitored based on analysis of the anterior naris (nostrils) temperature profile associated with the inspiration and expiration phases successively. OBJECTIVE: The aim of this study is to develop and investigate a new non-contact respiration monitoring modality for neonatal intensive care unit (NICU) using infrared thermography imaging. This development includes subsequent image processing (region of interest (ROI) detection) and optimization. Moreover, it includes further optimization of this non-contact respiration monitoring to be considered as physiological measurement inside NICU wards. RESULTS: Continuous wavelet transformation based on Debauches wavelet function was applied to detect the breathing signal within an image stream. Respiration was successfully monitored based on a 0.3°C to 0.5°C temperature difference between the inspiration and expiration phases. CONCLUSIONS: Although this method has been applied to adults before, this is the first time it was used in a newborn infant population inside the neonatal intensive care unit (NICU). The promising results suggest to include this technology into advanced NICU monitors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermistor at a Distance: Unobtrusive Measurement of Breathing
Fei, J., & Pavlidis, I. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2032415 · Cited by 201
Cited by
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Blanik, N., Abbas, A. K., Venema, B., Blazek, V., & Leonhardt, S. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.016012 · Cited by 58
Self-citationMedical Devices for Measuring Respiratory Rate in Children: a Review
Daw, W. (2016) · Journal of Advances in Biomedical Engineering and Technology · doi:10.15379/2409-3394.2016.03.01.04 · Cited by 35
“[29] were able to detect respiration in preterm infants on a neonatal unit based on a 0.”
Metadata
- Authors
- Abbas, A. K., Heimann, K., Jergus, K., Orlikowsky, T., & Leonhardt, S.
- Venue
- BioMedical Engineering OnLine
- Published
- 2011
- Volume
- 10
- Issue
- 1
- Pages
- 93
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2139284748
- Cited by
- 227
- References
- 1
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neonatal non-contact respiratory monitoring based on real-time infrared thermography. https://app.cochat.ai/papers/10.1186/1475-925x-10-93
- The paper
- Abbas, A. K., Heimann, K., Jergus, K., Orlikowsky, T., & Leonhardt, S. (2011). Neonatal non-contact respiratory monitoring based on real-time infrared thermography. BioMedical Engineering OnLine. https://doi.org/10.1186/1475-925x-10-93
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.