The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Performance of the Emotiv Epoc headset for P300-based applications
Open accessAbstract
BACKGROUND: For two decades, EEG-based Brain-Computer Interface (BCI) systems have been widely studied in research labs. Now, researchers want to consider out-of-the-lab applications and make this technology available to everybody. However, medical-grade EEG recording devices are still much too expensive for end-users, especially disabled people. Therefore, several low-cost alternatives have appeared on the market. The Emotiv Epoc headset is one of them. Although some previous work showed this device could suit the customer's needs in terms of performance, no quantitative classification-based assessments compared to a medical system are available. METHODS: This paper aims at statistically comparing a medical-grade system, the ANT device, and the Emotiv Epoc headset by determining their respective performances in a P300 BCI using the same electrodes. On top of that, a review of previous Emotiv studies and a discussion on practical considerations regarding both systems are proposed. Nine healthy subjects participated in this experiment during which the ANT and the Emotiv systems are used in two different conditions: sitting on a chair and walking on a treadmill at constant speed. RESULTS: The Emotiv headset performs significantly worse than the medical device; observed effect sizes vary from medium to large. The Emotiv headset has higher relative operational and maintenance costs than its medical-grade competitor. CONCLUSIONS: Although this low-cost headset is able to record EEG data in a satisfying manner, it should only be chosen for non critical applications such as games, communication systems, etc. For rehabilitation or prosthesis control, this lack of reliability may lead to serious consequences. For research purposes, the medical system should be chosen except if a lot of trials are available or when the Signal-to-Noise Ratio is high. This also suggests that the design of a specific low-cost EEG recording system for critical applications and research is still required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tabachnick, B. G., & Fidell, L. S. (1983) · Cited by 80,031
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Renard, Y., Lotte, F., Gibert, G., Congedo, M., Maby, E., Delannoy, V., Bertrand, O., & Lécuyer, A. (2010) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.19.1.35 · Cited by 830
Pfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540
xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Computation of measures of effect size for neuroscience data sets
Hentschke, H., & Stüttgen, M. C. (2011) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2011.07902.x · Cited by 410
Cited by
Choosing MUSE: Validation of a Low-Cost, Portable EEG System for ERP Research
Krigolson, O. E., Williams, C. C., Norton, A., Hassall, C. D., & Colino, F. L. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00109 · Cited by 412
Emotion Recognition for Human-Robot Interaction: Recent Advances and Future Perspectives
Spezialetti, M., Placidi, G., & Rossi, S. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.532279 · Cited by 293
Consumer Grade EEG Measuring Sensors as Research Tools: A Review
Sawangjai, P., Hompoonsup, S., Leelaarporn, P., Kongwudhikunakorn, S., & Wilaiprasitporn, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2962874 · Cited by 267
A scoping review on the use of consumer-grade EEG devices for research
Sabio, J., Williams, N. S., McArthur, G. M., & Badcock, N. A. (2024) · PLOS ONE · doi:10.1371/journal.pone.0291186 · Cited by 98
Kosch, T., Funk, M., Schmidt, A., & Chuang, L. L. (2018) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3229093 · Cited by 46
Metadata
- Authors
- Duvinage, M., Castermans, T., Petieau, M., Hoellinger, T., Cheron, G., & Dutoit, T.
- Venue
- BioMedical Engineering OnLine
- Published
- 2013
- Volume
- 12
- Issue
- 1
- Pages
- 56
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2141220295
- Cited by
- 322
- References
- 28
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of the Emotiv Epoc headset for P300-based applications. https://app.cochat.ai/papers/10.1186/1475-925x-12-56
- The paper
- Duvinage, M., Castermans, T., Petieau, M., Hoellinger, T., Cheron, G., & Dutoit, T. (2013). Performance of the Emotiv Epoc headset for P300-based applications. BioMedical Engineering OnLine. https://doi.org/10.1186/1475-925x-12-56
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.