Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Purpose: Nondegradable steel-and titanium-based implants are commonly used in orthopedic surgery. Although they provide maximal stability, they are also associated with interference on imaging modalities, may induce stress shielding, and additional explantation procedures may be necessary. Alternatively, degradable polymer implants are mechanically weaker and induce foreign body reactions. Degradable magnesium-based stents are currently being investigated in clinical trials for use in cardiovascular medicine. The magnesium alloy MgYREZr demonstrates good biocompatibility and osteoconductive properties. The aim of this prospective, randomized, clinical pilot trial was to determine if magnesium-based MgYREZr screws are equivalent to standard titanium screws for fixation during chevron osteotomy in patients with a mild hallux valgus. Methods: Patients (n=26) were randomly assigned to undergo osteosynthesis using either titanium or degradable magnesium-based implants of the same design. The 6 month follow-up period included clinical, laboratory, and radiographic assessments. Results: No significant differences were found in terms of the American Orthopaedic Foot and Ankle Society (AOFAS) score for hallux, visual analog scale for pain assessment, or range of motion (ROM) of the first metatarsophalangeal joint (MTPJ). No foreign body reactions, osteolysis, or systemic inflammatory reactions were detected. The groups were not significantly different in terms of radiographic or laboratory results. Conclusion: The radiographic and clinical results of this prospective controlled study demonstrate that degradable magnesium-based screws are equivalent to titanium screws for the treatment of mild hallux valgus deformities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Fast escape of hydrogen from gas cavities around corroding magnesium implants
Kuhlmann, J., Bartsch, I., Willbold, E., Schuchardt, S., Holz, O., Hort, N., Höche, D., Heineman, W. R., & Witte, F. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.10.008 · Cited by 310
Biodegradable magnesium implants for orthopedic applications
Waizy, H., Seitz, J.-M., Reifenrath, J., Weizbauer, A., Bach, F.-W., Meyer-Lindenberg, A., Denkena, B., & Windhagen, H. (2013) · Journal of Materials Science · doi:10.1007/s10853-012-6572-2 · Cited by 297
Self-citationABSORBABLE METAL IN BONE SURGERY: A FURTHER REPORT ON THE USE OF MAGNESIUM ALLOYS
McBRIDE, E. D. (1938) · Journal of the American Medical Association · doi:10.1001/jama.1938.02790530018007 · Cited by 231
Zhang, X., Yuan, G., Niu, J., Fu, P., & Ding, W. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.02.002 · Cited by 207
REPRODUCIBILITY OF THE RADIOGRAPHIC METATARSOPHALANGEAL ANGLE IN HALLUX SURGERY
Schneider, W., Csepan, R., & Knahr, K. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200303000-00015 · Cited by 135
Evaluation of the skin sensitizing potential of biodegradable magnesium alloys
Witte, F., Abeln, I.-D., Switzer, E., Kaese, V., Meyer‐Lindenberg, A., & Windhagen, H. J. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31713 · Cited by 92
Self-citationBöstman, O. M., Päivärinta, U., Partio, E. K., Manninen, M. J., Vasenius, J., Majola, A., & Rokkanen, P. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199212000-00036 · Cited by 50
Caminear, D. S., Pavlovich, R., & Pietrzak, W. S. (2005) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2005.02.003 · Cited by 46
In vitro corrosion of ZEK100 plates in Hank's Balanced Salt Solution
Waizy, H., Weizbauer, A., Modrejewski, C., Witte, F., Windhagen, H. J., Lucas, A., Kieke, M., Denkena, B., Behrens, P. J., Meyer‐Lindenberg, A., et al. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-12 · Cited by 43
Self-citationBiomechanical characterisation of a degradable magnesium-based (MgCa0.8) screw
Waizy, H., Weizbauer, A., Maibaum, M., Witte, F., Windhagen, H. J., Lucas, A., Denkena, B., Meyer‐Lindenberg, A., & Thorey, F. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4544-8 · Cited by 37
Self-citation
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Biomimetic porous scaffolds for bone tissue engineering
Wu, S., Liu, X., Yeung, K. W. K., Liu, C., & Yang, X. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.04.001 · Cited by 1,159
Zhao, D., Witte, F., Lu, F., Wang, J., Li, J., & Qin, L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.017 · Cited by 945
Metadata
- Authors
- Windhagen, H., Radtke, K., Weizbauer, A., Diekmann, J., Noll, Y., Kreimeyer, U., Schavan, R., Stukenborg-Colsman, C., & Waizy, H.
- Venue
- BioMedical Engineering OnLine
- Published
- 2013-07-03
- Volume
- 12
- Issue
- 1
- Pages
- 62-62
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2116506624
- Cited by
- 521
- References
- 11
- FWCI
- 23.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.