Objective evaluation of fatigue by EEG spectral analysis in steady-state visual evoked potential-based brain-computer interfaces
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The fatigue that users suffer when using steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs) can cause a number of serious problems such as signal quality degradation and system performance deterioration, users' discomfort and even risk of photosensitive epileptic seizures, posing heavy restrictions on the applications of SSVEP-based BCIs. Towards alleviating the fatigue, a fundamental step is to measure and evaluate it but most existing works adopt self-reported questionnaire methods which are subjective, offline and memory dependent. This paper proposes an objective and real-time approach based on electroencephalography (EEG) spectral analysis to evaluate the fatigue in SSVEP-based BCIs. METHODS: How the EEG indices (amplitudes in δ, θ, α and β frequency bands), the selected ratio indices (θ/α and (θ + α)/β), and SSVEP properties (amplitude and signal-to-noise ratio (SNR)) changes with the increasing fatigue level are investigated through two elaborate SSVEP-based BCI experiments, one validates mainly the effectiveness and another considers more practical situations. Meanwhile, a self-reported fatigue questionnaire is used to provide a subjective reference. ANOVA is employed to test the significance of the difference between the alert state and the fatigue state for each index. RESULTS: Consistent results are obtained in two experiments: the significant increases in α and (θ + α)/β, as well as the decrease in θ/α are found associated with the increasing fatigue level, indicating that EEG spectral analysis can provide robust objective evaluation of the fatigue in SSVEP-based BCIs. Moreover, the results show that the amplitude and SNR of the elicited SSVEP are significantly affected by users' fatigue. CONCLUSIONS: The experiment results demonstrate the feasibility and effectiveness of the proposed method as an objective and real-time evaluation of the fatigue in SSVEP-based BCIs. This method would be helpful in understanding the fatigue problem and optimizing the system design to alleviate the fatigue in SSVEP-based BCIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“BCIs measure the brain activities and translate the encoded human intentions to control computers, wheelchairs and robots, with a wide range of applications [1].”
BackgroundEEG alpha and theta oscillations reflect cognitive and memory performance: a review and analysis
Klimesch, W. (1999) · Brain Research Reviews · doi:10.1016/s0165-0173(98)00056-3 · Cited by 6,889
Basic mechanisms of cerebral rhythmic activities
Steriade, M., Gloor, P., Llinás, R. R., Lopes da Silva, F. H., & Mesulam, M.-M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90001-z · Cited by 1,137 · cited 4×
“The θ wave is related to sleep, work memory, cognitive performance and a variety of mental states [22,33].”
BackgroundInfluentialUsing EEG spectral components to assess algorithms for detecting fatigue
Jap, B. T., Lal, S., Fischer, P., & Bekiaris, E. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2007.12.043 · Cited by 729 · cited 2×
“A big increase was found in (θ + α)/β at the end of task in [28].”
BackgroundMethodDistinguishing sleepiness and fatigue: focus on definition and measurement
Shen, J., Barbera, J., & Shapiro, C. M. (2006) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2005.05.004 · Cited by 687 · cited 1×
“Fatigue is generally referred as a feeling of tiredness, reduced alertness, exhaustion, which impairs both capability and willing to perform a task [3-5].”
BackgroundA practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Control of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589 · cited 1×
“In the literature of SSVEP-based BCIs, fatigue and its influence in long-term experiments have been already noticed [12,13], however so far there is no systematic study on the fatigue problems.”
BackgroundDriver fatigue: Electroencephalography and psychological assessment
Lal, S. K. L., & Craig, A. (2002) · Psychophysiology · doi:10.1017/s0048577201393095 · Cited by 533 · cited 3×
“The results in α wave were consistent with the existing studies showing that the significant increase in α activity is associated with the increasing fatigue level [5,24,31,34,35].”
BackgroundResultElectroencephalographic study of drowsiness in simulated driving with sleep deprivation
Eoh, H. J., Chung, M. K., & Kim, S.-H. (2005) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2004.09.006 · Cited by 482
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
Cited by
Tran, Y., Craig, A., Craig, R., Chai, R., & Nguyen, H. (2020) · Psychophysiology · doi:10.1111/psyp.13554 · Cited by 313
Škola, F., Tinková, S., & Liarokapis, F. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00329 · Cited by 102
“Spectral analysis was performed on the latter half of the trials, and the fatigue index was computed from the ratio of theta/alpha power spectral density (adapted from Cao et al., 2014).”
MethodLi, G., & Zhang, D. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150667 · Cited by 80
Metadata
- Authors
- Cao, T., Wan, F., Wong, C. M., da Cruz, J. N., & Hu, Y.
- Venue
- BioMedical Engineering OnLine
- Published
- 2014-03-12
- Volume
- 13
- Issue
- 1
- Pages
- 28-28
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2154366912
- Cited by
- 188
- References
- 35
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.