Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 222

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of ultrasound lung comets by hand-held echocardiography

Open access
Bedetti, G, Gargani, L, Corbisiero, A, Frassi, F, Poggianti, E, Mottola, G · 2006 · Cardiovascular Ultrasound

Abstract

Background: Ultrasound lung comets (ULCs) are a clinically useful sign of extravascular lung water. They require very limited technology (2 D-echo), and a short learning curve. The aim of the present study is to compare ULCs information obtained by experienced echocardiologists using a full feature echocardiographic platform and by inexperienced sonographers using a hand-held echocardiography system. Methods: 20 consecutive in-hospital patients underwent, within 15' and in random order, 2 ultrasound examinations for ULCs by 2 observers with different specific expertise and different technology: 1) "high-tech veteran": ULCs assessment with full feature echocardiographic platform (HP Sonos 7500 Philips Medical Systems, Andover, MA, USA) by a trained echocardiologist, with ≥2 years expertise in ULCs assessment and accredited by the European Association of Echocardiography; 2) and a "low-tech beginner": ULCs assessment with hand-held echocardiography (Optigo; Philips, Andover, MA) by an echocardiographer with very limited (30') dedicated training on ULCs assessment. In each patient, ULC score was obtained by summing the number of comets from each of the scanning spaces in the anterior right and left hemithorax, from the second to the fifth intercostal space. Results: There was a significant, tight correlation (r = .958, p < 0.001) between the 2 observations in the same patient by "high-tech veteran" and "low-tech beginner". Conclusion: ULCs are equally reliable in the hands of highly experienced echocardiologists using full feature echocardiographic platforms and in the hands of absolute beginners with miniaturized, compact, and battery-equipped echocardiographic systems. From the technological and expertise viewpoint, ULCs are the "kindergarten" of echocardiography, ideally suited for bedside evaluation of patients with both known or suspected heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1476-7120-4-34

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 222

Metadata

Authors
Bedetti, G., Gargani, L., Corbisiero, A., Frassi, F., Poggianti, E., & Mottola, G.
Venue
Cardiovascular Ultrasound
Published
2006-08
Volume
4
Issue
1
Pages
34-34
ISSN
1476-7120 (ISSN-L)
OpenAlex
W2117987017
Cited by
222
References
1
FWCI
5.16
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of ultrasound lung comets by hand-held echocardiography. https://app.cochat.ai/papers/10.1186/1476-7120-4-34
The paper
Bedetti, G., Gargani, L., Corbisiero, A., Frassi, F., Poggianti, E., & Mottola, G. (2006). Evaluation of ultrasound lung comets by hand-held echocardiography. Cardiovascular Ultrasound. https://doi.org/10.1186/1476-7120-4-34

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.