CoChat

Comparison of two label-free global quantitation methods, APEX and 2D gel electrophoresis, applied to the Shigella dysenteriae proteome

Open access

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

The in vitro stationary phase proteome of the human pathogen Shigella dysenteriae serotype 1 (SD1) was quantitatively analyzed in Coomassie Blue G250 (CBB)-stained 2D gels. More than four hundred and fifty proteins, of which 271 were associated with distinct gel spots, were identified. In parallel, we employed 2D-LC-MS/MS followed by the label-free computationally modified spectral counting method APEX for absolute protein expression measurements. Of the 4502 genome-predicted SD1 proteins, 1148 proteins were identified with a false positive discovery rate of 5% and quantitated using 2D-LC-MS/MS and APEX. The dynamic range of the APEX method was approximately one order of magnitude higher than that of CBB-stained spot intensity quantitation. A squared Pearson correlation analysis revealed a reasonably good correlation (R2 = 0.67) for protein quantities surveyed by both methods. The correlation was decreased for protein subsets with specific physicochemical properties, such as low Mr values and high hydropathy scores. Stoichiometric ratios of subunits of protein complexes characterized in E. coli were compared with APEX quantitative ratios of orthologous SD1 protein complexes. A high correlation was observed for subunits of soluble cellular protein complexes in several cases, demonstrating versatile applications of the APEX method in quantitative proteomics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1477-5956-7-22

Cites

Statistics

Figures

Figure 1 Flow chart of data analysis approach. The data analysis approaches employed for the LC-MS/MS-APEX and 2-DE/MS methodologies are shown here. The numbers in both approaches represent the average of three replicate experiments. 1148 SD1 proteins were quantitated by LC-MS/MS-APEX and 271 proteins from 2D gels.
Figure 1 Flow chart of data analysis approach. The data analysis approaches employed for the LC-MS/MS-APEX and 2-DE/MS methodologies are shown here. The numbers in both approaches represent the average of three replicate experiments. 1148 SD1 proteins were quantitated by LC-MS/MS-APEX and 271 proteins from 2D gels.CC BY · PubMed Central
Figure 2 Annotated proteome map of 2D gel. SD1 proteins were analyzed by 2-DE in the pH range 4 – 7. 271 proteins mapped to the gel by 2-DE/MS are represented by spot numbers. 2-DE protein abundances of 255 proteins matched to unique spots were correlated with APEX abundances.
Figure 2 Annotated proteome map of 2D gel. SD1 proteins were analyzed by 2-DE in the pH range 4 – 7. 271 proteins mapped to the gel by 2-DE/MS are represented by spot numbers. 2-DE protein abundances of 255 proteins matched to unique spots were correlated with APEX abundances.CC BY · PubMed Central
Figure 3 Correlation of protein abundances estimated by APEX vs. 2-DE. 255 SD1 proteins common to both the APEX and 2-DE datasets were correlated for protein abundance estimations by the two methodologies for an overall Spearman rank correlation of Rs = 0.81 and squared Pearson correlation of R2 = 0.67.
Figure 3 Correlation of protein abundances estimated by APEX vs. 2-DE. 255 SD1 proteins common to both the APEX and 2-DE datasets were correlated for protein abundance estimations by the two methodologies for an overall Spearman rank correlation of Rs = 0.81 and squared Pearson correlation of R2 = 0.67.CC BY · PubMed Central
Figure 4 Correlation of protein abundances estimated by APEX vs. 2-DE based on protein Mr. Proteins quantitated by APEX and 2-DE were compared against all proteins predicted for the Sd197 genome sorted by Mr in bins of 10 kDa width (Fig. 4a). Correlation of protein abundances estimated by APEX vs. 2-DE decreased for low Mr proteins at <20 kDa (R2 = 0.51), but increased for proteins in the 20 – 70 kDa Mr range (R2 = 0.73) compared to the overall abundance correlation (R2 = 0.67).
Figure 4 Correlation of protein abundances estimated by APEX vs. 2-DE based on protein Mr. Proteins quantitated by APEX and 2-DE were compared against all proteins predicted for the Sd197 genome sorted by Mr in bins of 10 kDa width (Fig. 4a). Correlation of protein abundances estimated by APEX vs. 2-DE decreased for low Mr proteins at <20 kDa (R2 = 0.51), but increased for proteins in the 20 – 70 kDa Mr range (R2 = 0.73) compared to the overall abundance correlation (R2 = 0.67).CC BY · PubMed Central
Figure 5 Correlation of protein abundances estimated by APEX vs. 2-DE based on hydropathy score. Hydropathy (GRAVY) score of a protein was calculated as the arithmetic mean of the sum of the hydropathic indices of each amino acid. The left end of the scale in Fig. 5a represents hydrophilic proteins, and the right end of the scale represents hydrophobic proteins. Within a particular hydropathy range, the number of proteins quantitated by APEX and 2-DE were compared against all protens predicted for Sd197. Correlation of protein abundances estimated by APEX vs. 2-DE decreased for very hydrophobic (R2 = 0.61) and also for very hydrophilic proteins (R2 = 0.52) compared to the overall abundance correlation.
Figure 5 Correlation of protein abundances estimated by APEX vs. 2-DE based on hydropathy score. Hydropathy (GRAVY) score of a protein was calculated as the arithmetic mean of the sum of the hydropathic indices of each amino acid. The left end of the scale in Fig. 5a represents hydrophilic proteins, and the right end of the scale represents hydrophobic proteins. Within a particular hydropathy range, the number of proteins quantitated by APEX and 2-DE were compared against all protens predicted for Sd197. Correlation of protein abundances estimated by APEX vs. 2-DE decreased for very hydrophobic (R2 = 0.61) and also for very hydrophilic proteins (R2 = 0.52) compared to the overall abundance correlation.CC BY · PubMed Central
Figure 6 Correlation of protein abundances estimated by APEX vs. 2-DE based on aromaticity. Proteins predicted for Sd197 genome were sorted based on the frequency of aromatic amino acids F, W and Y in proteins and compared with proteins quantitated by APEX and 2-DE (Fig. 6a). Correlation of protein abundances estimated by APEX vs. 2-DE decreased with increase in non-polarity (>0.08 aromaticity values, R2 = 0.63) and increase in polarity (<0.06 aromaticity values, R2 = 0.59) compared to the overall abundance correlation.
Figure 6 Correlation of protein abundances estimated by APEX vs. 2-DE based on aromaticity. Proteins predicted for Sd197 genome were sorted based on the frequency of aromatic amino acids F, W and Y in proteins and compared with proteins quantitated by APEX and 2-DE (Fig. 6a). Correlation of protein abundances estimated by APEX vs. 2-DE decreased with increase in non-polarity (>0.08 aromaticity values, R2 = 0.63) and increase in polarity (<0.06 aromaticity values, R2 = 0.59) compared to the overall abundance correlation.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

References 60 · Cited by 35

Metadata

Authors
Kuntumalla, S., Braisted, J. C., Huang, S.-T., Parmar, P. P., Clark, D. J., Alami, H., Zhang, Q., Donohue-Rolfe, A., Tzipori, S., Fleischmann, R. D., Peterson, S. N., & Pieper, R.
Affiliations
  • J. Craig Venter Institute (US)
  • Tufts University (US)
Corresponding author
  • Kuntumalla, Srilatha
  • Pieper, Rembert
Venue
Proteome Science
Published
2009
Volume
7
Issue
1
Pages
22
ISSN
1477-5956 (ISSN-L)
OpenAlex
W1988642036
Cited by
35
References
60
Citations by year
2021: 1 · 2019: 1 · 2018: 1 · 2016: 3 · 2015: 1 · 2014: 7 · 2013: 5 · 2012: 5
FWCI
2.29
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Proteome Science (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • U.S. Department of Health and Human Services (N01-AI-30050)
  • University of Texas at Austin
  • Canadian Institute for Theoretical Astrophysics
  • National Institutes of Health (7r29ai030050-06, N01-AI-30050)
  • National Institute of Allergy and Infectious Diseases (N01-AI15447, N01 AI30050)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
Keywords
APEX, label-free quantification, two-dimensional gel electrophoresis, 2D-LC-MS/MS, spectral counting, protein stoichiometry, protein complexes, dynamic range, method comparison

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of two label-free global quantitation methods, APEX and 2D gel electrophoresis, applied to the Shigella dysenteriae proteome. https://app.cochat.ai/papers/10.1186/1477-5956-7-22
The paper
Kuntumalla, S., Braisted, J. C., Huang, S.-T., Parmar, P. P., Clark, D. J., Alami, H., Zhang, Q., Donohue-Rolfe, A., Tzipori, S., Fleischmann, R. D., Peterson, S. N., & Pieper, R. (2009). Comparison of two label-free global quantitation methods, APEX and 2D gel electrophoresis, applied to the Shigella dysenteriae proteome. Proteome Science. https://doi.org/10.1186/1477-5956-7-22

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.