Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 225

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Cardiac resynchronization therapy guided by late gadolinium-enhancement cardiovascular magnetic resonance

Open access
Leyva, Francisco, Foley, Paul WX, Chalil, Shajil, Ratib, Karim, Smith, Russell EA, Prinzen, Frits, Auricchio, Angelo · 2011 · Journal of Cardiovascular Magnetic Resonance

Abstract

BACKGROUND: Myocardial scarring at the LV pacing site leads to incomplete resynchronization and a suboptimal symptomatic response to CRT. We sought to determine whether the use of late gadolinium cardiovascular magnetic resonance (LGE-CMR) to guide left ventricular (LV) lead deployment influences the long-term outcome of cardiac resynchronization therapy (CRT). METHODS: 559 patients with heart failure (age 70.4 ± 10.7 yrs [mean ± SD]) due to ischemic or non-ischemic cardiomyopathy underwent CRT. Implantations were either guided (+CMR) or not guided (-CMR) by LGE-CMR prior to implantation. Fluoroscopy and LGE-CMR were used to localize the LV lead tip and and myocardial scarring retrospectively. Clinical events were assessed in three groups: +CMR and pacing scar (+CMR+S); CMR and not pacing scar (+CMR-S), and; LV pacing not guided by CMR (-CMR). RESULTS: Over a maximum follow-up of 9.1 yrs, +CMR+S had the highest risk of cardiovascular death (HR: 6.34), cardiovascular death or hospitalizations for heart failure (HR: 5.57) and death from any cause or hospitalizations for major adverse cardiovascular events (HR: 4.74) (all P < 0.0001), compared with +CMR-S. An intermediate risk of meeting these endpoints was observed for -CMR, with HRs of 1.51 (P = 0.0726), 1.61 (P = 0.0169) and 1.87 (p = 0.0005), respectively. The +CMR+S group had the highest risk of death from pump failure (HR: 5.40, p < 0.0001) and sudden cardiac death (HR: 4.40, p = 0.0218), in relation to the +CMR-S group. CONCLUSIONS: Compared with a conventional implantation approach, the use of LGE-CMR to guide LV lead deployment away from scarred myocardium results in a better clinical outcome after CRT. Pacing scarred myocardium was associated with the worst outcome, in terms of both pump failure and sudden cardiac death.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1532-429x-13-29

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 225

Metadata

Authors
Leyva, F., Foley, P. W., Chalil, S., Ratib, K., Smith, R. E., Prinzen, F., & Auricchio, A.
Venue
Journal of Cardiovascular Magnetic Resonance
Publisher
Elsevier BV
Published
2011-01
Volume
13
Issue
1
Pages
29
ISSN
1097-6647 (ISSN-L)
OpenAlex
W2156019867
Cited by
225
References
2
FWCI
9.02
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac resynchronization therapy guided by late gadolinium-enhancement cardiovascular magnetic resonance. https://app.cochat.ai/papers/10.1186/1532-429x-13-29
The paper
Leyva, F., Foley, P. W., Chalil, S., Ratib, K., Smith, R. E., Prinzen, F., & Auricchio, A. (2011). Cardiac resynchronization therapy guided by late gadolinium-enhancement cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance. https://doi.org/10.1186/1532-429x-13-29

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.