Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Quantification of left ventricular trabeculae using fractal analysis

Open access
Captur, Gabriella, Muthurangu, Vivek, Cook, Christopher, Flett, Andrew S, Wilson, Robert, Barison, Andrea, Sado, Daniel M, Anderson, Sarah, McKenna, William J, Mohun, Timothy J, Elliott, Perry M, Moon, James C · 2013 · Journal of Cardiovascular Magnetic Resonance

Abstract

BACKGROUND: Left ventricular noncompaction (LVNC) is a myocardial disorder characterized by excessive left ventricular (LV) trabeculae. Current methods for quantification of LV trabeculae have limitations. The aim of this study is to describe a novel technique for quantifying LV trabeculation using cardiovascular magnetic resonance (CMR) and fractal geometry. Observing that trabeculae appear complex and irregular, we hypothesize that measuring the fractal dimension (FD) of the endocardial border provides a quantitative parameter that can be used to distinguish normal from abnormal trabecular patterns. METHODS: Fractal analysis is a method of quantifying complex geometric patterns in biological structures. The resulting FD is a unitless measure index of how completely the object fills space. FD increases with increased structural complexity. LV FD was measured using a box-counting method on CMR short-axis cine stacks. Three groups were studied: LVNC (defined by Jenni criteria), n=30(age 41±13; men, 16); healthy whites, n=75(age, 46±16; men, 36); healthy blacks, n=30(age, 40±11; men, 15). RESULTS: In healthy volunteers FD varied in a characteristic pattern from base to apex along the LV. This pattern was altered in LVNC where apical FD were abnormally elevated. In healthy volunteers, blacks had higher FD than whites in the apical third of the LV (maximal apical FD: 1.253±0.005 vs. 1.235±0.004, p<0.01) (mean±s.e.m.). Comparing LVNC with healthy volunteers, maximal apical FD was higher in LVNC (1.392±0.010, p<0.00001). The fractal method was more accurate and reproducible (ICC, 0.97 and 0.96 for intra and inter-observer readings) than two other CMR criteria for LVNC (Petersen and Jacquier). CONCLUSIONS: FD is higher in LVNC patients compared to healthy volunteers and is higher in healthy blacks than in whites. Fractal analysis provides a quantitative measure of trabeculation and has high reproducibility and accuracy for LVNC diagnosis when compared to current CMR criteria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1532-429x-15-36

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 229

Metadata

Authors
Captur, G., Muthurangu, V., Cook, C., Flett, A. S., Wilson, R., Barison, A., Sado, D. M., Anderson, S., McKenna, W. J., Mohun, T. J., Elliott, P. M., & Moon, J. C.
Venue
Journal of Cardiovascular Magnetic Resonance
Publisher
Elsevier BV
Published
2013-01
Volume
15
Issue
1
Pages
36
ISSN
1097-6647 (ISSN-L)
OpenAlex
W2154669783
Cited by
229
References
1
FWCI
10.38
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of left ventricular trabeculae using fractal analysis. https://app.cochat.ai/papers/10.1186/1532-429x-15-36
The paper
Captur, G., Muthurangu, V., Cook, C., Flett, A. S., Wilson, R., Barison, A., Sado, D. M., Anderson, S., McKenna, W. J., Mohun, T. J., Elliott, P. M., & Moon, J. C. (2013). Quantification of left ventricular trabeculae using fractal analysis. Journal of Cardiovascular Magnetic Resonance. https://doi.org/10.1186/1532-429x-15-36

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.