Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cardiac phenotypes, such as left ventricular (LV) mass, demonstrate high heritability although most genes associated with these complex traits remain unidentified. Genome-wide association studies (GWAS) have relied on conventional 2D cardiovascular magnetic resonance (CMR) as the gold-standard for phenotyping. However this technique is insensitive to the regional variations in wall thickness which are often associated with left ventricular hypertrophy and require large cohorts to reach significance. Here we test whether automated cardiac phenotyping using high spatial resolution CMR atlases can achieve improved precision for mapping wall thickness in healthy populations and whether smaller sample sizes are required compared to conventional methods. METHODS: LV short-axis cine images were acquired in 138 healthy volunteers using standard 2D imaging and 3D high spatial resolution CMR. A multi-atlas technique was used to segment and co-register each image. The agreement between methods for end-diastolic volume and mass was made using Bland-Altman analysis in 20 subjects. The 3D and 2D segmentations of the LV were compared to manual labeling by the proportion of concordant voxels (Dice coefficient) and the distances separating corresponding points. Parametric and nonparametric data were analysed with paired t-tests and Wilcoxon signed-rank test respectively. Voxelwise power calculations used the interstudy variances of wall thickness. RESULTS: The 3D volumetric measurements showed no bias compared to 2D imaging. The segmented 3D images were more accurate than 2D images for defining the epicardium (Dice: 0.95 vs 0.93, P<0.001; mean error 1.3 mm vs 2.2 mm, P<0.001) and endocardium (Dice 0.95 vs 0.93, P<0.001; mean error 1.1 mm vs 2.0 mm, P<0.001). The 3D technique resulted in significant differences in wall thickness assessment at the base, septum and apex of the LV compared to 2D (P<0.001). Fewer subjects were required for 3D imaging to detect a 1 mm difference in wall thickness (72 vs 56, P<0.001). CONCLUSIONS: High spatial resolution CMR with automated phenotyping provides greater power for mapping wall thickness than conventional 2D imaging and enables a reduction in the sample size required for studies of environmental and genetic determinants of LV wall thickness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A power calculation guide for fMRI studies
Mumford, J. A. (2012) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nss059 · Cited by 171 · cited 1×
“Neuroimaging studies have modelled the statistical power of 3D imaging [47] and our calculations indicate a significant reduction in sample size is possible over most of the myocardium for detecting differences in wall thickness.”
BackgroundHua, X., Lee, S., Yanovsky, I., Leow, A. D., Chou, Y.-Y., Ho, A. J., Gutman, B., Toga, A. W., Jack, C. R., Bernstein, M. A., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.011 · Cited by 145
Cited by
Oktay, O., Ferrante, E., Kamnitsas, K., Heinrich, M., Bai, W., Caballero, J., Cook, S. A., de Marvao, A., Dawes, T., O'Regan, D. P., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2743464 · Cited by 751
“Each image pair is acquired from a healthy subject using a standard imaging protocol [4], [15].”
MethodResultSelf-citationTitin-truncating variants affect heart function in disease cohorts and the general population
Schafer, S., de Marvao, A., Adami, E., Fiedler, L. R., Ng, B., Khin, E., Rackham, O. J. L., van Heesch, S., Pua, C. J., Kui, M., et al. (2017) · Nature Genetics · doi:10.1038/ng.3719 · Cited by 362
Self-citationGenetics of Sudden Cardiac Death
Bezzina, C. R., Lahrouchi, N., & Priori, S. G. (2015) · Circulation Research · doi:10.1161/circresaha.116.304030 · Cited by 266
Deep reinforcement learning in computer vision: a comprehensive survey
Le, N., Rathour, V. S., Yamazaki, K., Luu, K., & Savvides, M. (2022) · Artificial Intelligence Review · doi:10.1007/s10462-021-10061-9 · Cited by 261
Duan, J., Bello, G., Schlemper, J., Bai, W., Dawes, T. J. W., Biffi, C., de Marvao, A., Doumoud, G., O'Regan, D. P., & Rueckert, D. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2894322 · Cited by 227
Self-citation
Metadata
- Authors
- de Marvao, A., Dawes, T. J., Shi, W., Minas, C., Keenan, N. G., Diamond, T., Durighel, G., Montana, G., Rueckert, D., Cook, S. A., & O'Regan, D. P.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 16
- Issue
- 1
- Pages
- 16
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2130775436
- Cited by
- 50
- References
- 3
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power. https://app.cochat.ai/papers/10.1186/1532-429x-16-16
- The paper
- de Marvao, A., Dawes, T. J., Shi, W., Minas, C., Keenan, N. G., Diamond, T., Durighel, G., Montana, G., Rueckert, D., Cook, S. A., & O'Regan, D. P. (2014). Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power. Journal of Cardiovascular Magnetic Resonance. https://doi.org/10.1186/1532-429x-16-16
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.