Basophil activation test compared to skin prick test and fluorescence enzyme immunoassay for aeroallergen-specific Immunoglobulin-E
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Skin prick test (SPT) and fluorescence enzyme immunoassay (FEIA) are widely used for the diagnosis of Immunoglobulin-E (IgE)-mediated allergic disease. Basophil activation test (BAT) could obviate disadvantages of SPT and FEIA. However, it is not known whether BAT gives similar results as SPT or FEIA for aeroallergens. OBJECTIVES: In this study, we compared the results of SPT, BAT and FEIA for different aeroallergens. METHODS: We performed BAT, SPT and FEIA in 41 atopic subjects (symptomatic and with positive SPT for at least 1 of 9 common aeroallergens) and 31 non-atopic subjects (asymptomatic and with negative SPT). RESULTS: Correlations between SPT and BAT, SPT and FEIA, and BAT and FEIA results were statistically significant but imperfect. Using SPT as the "gold standard", BAT and FEIA were similar in sensitivity. However, BAT had lower specificity than FEIA. False positive (BATposSPTneg) results were frequent in those atopic subjects who were allergic by SPT to a different allergen and rare in non-atopic subjects. The false positivity in atopic subjects was due in part to high levels of serum Total-IgE (T-IgE) levels in atopic individuals that lead to basophil activation upon staining with fluorochrome-labeled anti-IgE. CONCLUSION: As an alternative to SPT in persons allergic to aeroallergens, BAT in its present form is useful for distinguishing atopic from non-atopic persons. However, BAT in its present form is less specific than FEIA when determining the allergen which a patient is allergic to. This is due to IgE staining-induced activation of atopic person's basophils and/or nonspecific hyperreactivity of atopic person's basophils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Arbes Jr., S. J., Gergen, P. J., Elliott, L., & Zeldin, D. C. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.05.017 · Cited by 639 · cited 2×
“All subjects had a valid SPT as defined by at least 1 mm diameter difference between the positive and negative controls [16].”
BackgroundSkin testing: a survey of allergists
Oppenheimer, J., & Nelson, H. S. (2006) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)61034-4 · Cited by 92
Cited by
Ram, F. S., Robinson, S., Black, P. N., & Picot, J. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001116.pub2 · Cited by 367
Pollen Allergens for Molecular Diagnosis
Pablos, I., Wildner, S., Asam, C., Wallner, M., & Gadermaier, G. (2016) · Current Allergy and Asthma Reports · doi:10.1007/s11882-016-0603-z · Cited by 71
Popescu, F.-D., & Vieru, M. (2018) · World Journal of Methodology · doi:10.5662/wjm.v8.i3.17 · Cited by 67
Leśniak, M., Dyga, W., Rusinek, B., Mazur, M., & Czarnobilska, E. (2016) · Polish Archives of Internal Medicine · doi:10.20452/pamw.3525 · Cited by 13
Metadata
- Authors
- Khan, F. M., Ueno-Yamanouchi, A., Serushago, B., Bowen, T., Lyon, A. W., Lu, C., & Storek, J.
- Venue
- Allergy, Asthma & Clinical Immunology
- Published
- 2012-01-20
- Volume
- 8
- Issue
- 1
- Pages
- 1-1
- ISSN
- 1710-1484 (ISSN-L)
- 1710-1492
- OpenAlex
- W2070383293
- Cited by
- 36
- References
- 2
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Basophil activation test compared to skin prick test and fluorescence enzyme immunoassay for aeroallergen-specific Immunoglobulin-E. https://app.cochat.ai/papers/10.1186/1710-1492-8-1
- The paper
- Khan, F. M., Ueno-Yamanouchi, A., Serushago, B., Bowen, T., Lyon, A. W., Lu, C., & Storek, J. (2012). Basophil activation test compared to skin prick test and fluorescence enzyme immunoassay for aeroallergen-specific Immunoglobulin-E. Allergy, Asthma & Clinical Immunology. https://doi.org/10.1186/1710-1492-8-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.