Abstract
Transcutaneous neuromuscular electrical stimulation applied in clinical settings is currently characterized by a wide heterogeneity of stimulation protocols and modalities. Practitioners usually refer to anatomic charts (often provided with the user manuals of commercially available stimulators) for electrode positioning, which may lead to inconsistent outcomes, poor tolerance by the patients, and adverse reactions. Recent evidence has highlighted the crucial importance of stimulating over the muscle motor points to improve the effectiveness of neuromuscular electrical stimulation. Nevertheless, the correct electrophysiological definition of muscle motor point and its practical significance are not always fully comprehended by therapists and researchers in the field. The commentary describes a straightforward and quick electrophysiological procedure for muscle motor point identification. It consists in muscle surface mapping by using a stimulation pen-electrode and it is aimed at identifying the skin area above the muscle where the motor threshold is the lowest for a given electrical input, that is the skin area most responsive to electrical stimulation. After the motor point mapping procedure, a proper placement of the stimulation electrode(s) allows neuromuscular electrical stimulation to maximize the evoked tension, while minimizing the dose of the injected current and the level of discomfort. If routinely applied, we expect this procedure to improve both stimulation effectiveness and patient adherence to the treatment. The aims of this clinical commentary are to present an optimized procedure for the application of neuromuscular electrical stimulation and to highlight the clinical implications related to its use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuromuscular electrical stimulation for skeletal muscle function.
Doucet, B. M. M., Lam, A., & Griffin, L. (2012) · PubMed Central · Cited by 687
Physiological and methodological considerations for the use of neuromuscular electrical stimulation
Maffiuletti, N. A. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1502-y · Cited by 651 · cited 3×
“NMES is usually delivered using one or more active electrodes positioned in the proximity to the MPs and one reference electrode closing the stimulation loop [2].”
BackgroundMethodInfluentialSelf-citationRecruitment Patterns in Human Skeletal Muscle During Electrical Stimulation
Gregory, C. M., & Bickel, C. S. (2005) · Physical Therapy · doi:10.1093/ptj/85.4.358 · Cited by 612 · cited 1×
“This electrode configuration implies that the recruitment of motor units is not only limited, but also spatially fixed [10,11].”
BackgroundJones, D. A., Bigland-Ritchie, B., & Edwards, R. H. T. (1979) · Experimental Neurology · doi:10.1016/0014-4886(79)90279-6 · Cited by 588 · cited 2×
“Therefore, the same muscle units are repeatedly activated by the same amount of electrical current, which, in turn, hastens the onset of muscle fatigue [10,12].”
BackgroundBigland-Ritchie, B., Jones, D. A., & Woods, J. J. (1979) · Experimental Neurology · doi:10.1016/0014-4886(79)90280-2 · Cited by 349 · cited 2×
“Therefore, the same muscle units are repeatedly activated by the same amount of electrical current, which, in turn, hastens the onset of muscle fatigue [10,12].”
BackgroundBotter, A., Oprandi, G., Lanfranco, F., Allasia, S., Maffiuletti, N. A., & Minetto, M. A. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2093-y · Cited by 260 · cited 1×
“In other words, it represents the skin area above the muscle where the motor threshold is the lowest for a given electrical input [5-7].”
BackgroundSelf-citationEvaluation of methods for electrical stimulation of human skeletal muscle in situ
Hultman, E., Sj�holm, H., J�derholm-Ek, I., & Krynicki, J. (1983) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00581062 · Cited by 198 · cited 1×
“Transcutaneous neuromuscular electrical stimulation (NMES) involves the application of electrical stimuli to superficial skeletal muscles, with the main objective to trigger visible and valid muscle contractions due to the activation of motor neuron axons or intramuscular axonal branches [1].”
BackgroundBinder‐Macleod, S. A., & Snyder‐Mackler, L. (1993) · Physical Therapy · doi:10.1093/ptj/73.12.902 · Cited by 170 · cited 1×
“Therefore, the same muscle units are repeatedly activated by the same amount of electrical current, which, in turn, hastens the onset of muscle fatigue [10,12].”
BackgroundWalls, R. J., McHugh, G., O’Gorman, D. J., Moyna, N. M., & O’Byrne, J. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-119 · Cited by 139 · cited 1×
““prehabilitation”) [3].”
Bruce-Brand, R. A., Walls, R. J., Ong, J. C., Emerson, B. S., O’Byrne, J. M., & Moyna, N. M. (2012) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-13-118 · Cited by 129 · cited 2×
“The multipath NMES modality was superior to traditional NMES performed with two active electrodes positioned over the vasti MPs and one dispersive electrode closing the stimulation loop [14] and comparable to volitional resistance training [16] for the improvement of functional capacity and quadriceps strength.”
Method
Cited by
Nussbaum, E. L., Houghton, P., Anthony, J., Rennie, S., Shay, B. L., & Hoens, A. M. (2017) · Physiotherapy Canada · doi:10.3138/ptc.2015-88 · Cited by 211
Maffiuletti, N. A., Green, D. A., Vaz, M. A., & Dirks, M. L. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01031 · Cited by 50
“Before Spaceflight Prior to flight, muscle motor points should be localized and marked on the skin according to the methodology proposed by Gobbo and co-workers (Gobbo et al., 2014).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Gobbo, M., Maffiuletti, N. A., Orizio, C., & Minetto, M. A.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014-02-25
- Volume
- 11
- Issue
- 1
- Pages
- 17-17
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2119664527
- Cited by
- 211
- References
- 16
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Muscle motor point identification is essential for optimizing neuromuscular electrical stimulation use. https://app.cochat.ai/papers/10.1186/1743-0003-11-17
- The paper
- Gobbo, M., Maffiuletti, N. A., Orizio, C., & Minetto, M. A. (2014). Muscle motor point identification is essential for optimizing neuromuscular electrical stimulation use. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-11-17