The DOI matches its Crossref record.
Wearable kinesthetic system for capturing and classifying upper limb gesture in post-stroke rehabilitation
Open accessAbstract
Background: Monitoring body kinematics has fundamental relevance in several biological and technical disciplines. In particular the possibility to exactly know the posture may furnish a main aid in rehabilitation topics. In the present work an innovative and unobtrusive garment able to detect the posture and the movement of the upper limb has been introduced, with particular care to its application in post stroke rehabilitation field by describing the integration of the prototype in a healthcare service. Methods: This paper deals with the design, the development and implementation of a sensing garment, from the characterization of innovative comfortable and diffuse sensors we used to the methodologies employed to gather information on the posture and movement which derive from the entire garments. Several new algorithms devoted to the signal acquisition, the treatment and posture and gesture reconstruction are introduced and tested. Results: Data obtained by means of the sensing garment are analyzed and compared with the ones recorded using a traditional movement tracking system. Conclusion: The main results treated in this work are summarized and remarked. The system was compared with a commercial movement tracking system (a set of electrogoniometers) and it performed the same accuracy in detecting upper limb postures and movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Sensor for Measuring Strain in Textile
Mattmann, C., Clemens, F., & Tröster, G. (2008) · Sensors · doi:10.3390/s8063719 · Cited by 464
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
Cochrane, C., Koncar, V., Lewandowski, M., & Dufour, C. (2007) · Sensors · doi:10.3390/s7040473 · Cited by 376
Seyedin, M. Z., Razal, J. M., Innis, P. C., & Wallace, G. G. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303905 · Cited by 305
Metadata
- Authors
- Tognetti, A., Lorussi, F., Bartalesi, R., Quaglini, S., Tesconi, M., Zupone, G., & De Rossi, D.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2005-03-02
- Volume
- 2
- Issue
- 1
- Pages
- 8-8
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2106975581
- Cited by
- 174
- References
- 0
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable kinesthetic system for capturing and classifying upper limb gesture in post-stroke rehabilitation. https://app.cochat.ai/papers/10.1186/1743-0003-2-8
- The paper
- Tognetti, A., Lorussi, F., Bartalesi, R., Quaglini, S., Tesconi, M., Zupone, G., & De Rossi, D. (2005). Wearable kinesthetic system for capturing and classifying upper limb gesture in post-stroke rehabilitation. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-2-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.