Innovative gait robot for the repetitive practice of floor walking and stair climbing up and down in stroke patients
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Stair climbing up and down is an essential part of everyday's mobility. To enable wheelchair-dependent patients the repetitive practice of this task, a novel gait robot, G-EO-Systems (EO, Lat: I walk), based on the end-effector principle, has been designed. The trajectories of the foot plates are freely programmable enabling not only the practice of simulated floor walking but also stair climbing up and down. The article intended to compare lower limb muscle activation patterns of hemiparetic subjects during real floor walking and stairs climbing up, and during the corresponding simulated conditions on the machine, and secondly to demonstrate gait improvement on single case after training on the machine. METHODS: The muscle activation pattern of seven lower limb muscles of six hemiparetic patients during free and simulated walking on the floor and stair climbing was measured via dynamic electromyography. A non-ambulatory, sub-acute stroke patient additionally trained on the G-EO-Systems every workday for five weeks. RESULTS: The muscle activation patterns were comparable during the real and simulated conditions, both on the floor and during stair climbing up. Minor differences, concerning the real and simulated floor walking conditions, were a delayed (prolonged) onset (duration) of the thigh muscle activation on the machine across all subjects. Concerning stair climbing conditions, the shank muscle activation was more phasic and timely correct in selected patients on the device. The severely affected subject regained walking and stair climbing ability. CONCLUSIONS: The G-EO-Systems is an interesting new option in gait rehabilitation after stroke. The lower limb muscle activation patterns were comparable, a training thus feasible, and the positive case report warrants further clinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An organizing principle for a class of voluntary movements
Hogan, N. (1984) · The Journal of Neuroscience · doi:10.1523/jneurosci.04-11-02745.1984 · Cited by 1,330
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Recovery of walking function in stroke patients: The copenhagen stroke study
Jørgensen, H. S., Nakayama, H., Raaschou, H. O., & Olsen, T. S. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80038-7 · Cited by 1,164
An integrated biomechanical analysis of normal stair ascent and descent
McFadyen, B. J., & Winter, D. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90282-5 · Cited by 693
Locomotor Training After Human Spinal Cord Injury: A Series of Case Studies
Behrman, A. L., & Harkema, S. J. (2000) · Physical Therapy · doi:10.1093/ptj/80.7.688 · Cited by 593
DIFFERENT TYPES OF DISTURBED MOTOR CONTROL IN GAIT OF HEMIPARETIC PATIENTS
KNUTSSON, E., & RICHARDS, C. (1979) · Brain · doi:10.1093/brain/102.2.405 · Cited by 526
Foot Trajectory in Human Gait: A Precise and Multifactorial Motor Control Task
Winter, D. A. (1992) · Physical Therapy · doi:10.1093/ptj/72.1.45 · Cited by 505
Husemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Self-citation
Cited by
Electromechanical-assisted training for walking after stroke
Mehrholz, J., Thomas, S., Werner, C., Kugler, J., Pohl, M., & Elsner, B. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub4 · Cited by 564
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Nam, K. Y., Kim, H. J., Kwon, B. S., Park, J.-W., Lee, H. J., & Yoo, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0232-3 · Cited by 302
Morone, G., Paolucci, S., Cherubini, A., De Angelis, D., Venturiero, V., Coiro, P., & Iosa, M. (2017) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s114102 · Cited by 297
Exoskeleton and End‐Effector Robots for Upper and Lower Limbs Rehabilitation: Narrative Review
Molteni, F., Gasperini, G., Cannaviello, G., & Guanziroli, E. (2018) · PM&R · doi:10.1016/j.pmrj.2018.06.005 · Cited by 274
Towards more effective robotic gait training for stroke rehabilitation: a review
Pennycott, A., Wyss, D., Vallery, H., Klamroth-Marganska, V., & Riener, R. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-65 · Cited by 259
Robotic gait rehabilitation and substitution devices in neurological disorders: where are we now?
Calabrò, R. S., Cacciola, A., Bertè, F., Manuli, A., Leo, A., Bramanti, A., Naro, A., Milardi, D., & Bramanti, P. (2016) · Neurological Sciences · doi:10.1007/s10072-016-2474-4 · Cited by 259
Electromechanical-assisted training for walking after stroke
Mehrholz, J., Thomas, S., Kugler, J., Pohl, M., & Elsner, B. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub5 · Cited by 254
Alia, C., Spalletti, C., Lai, S., Panarese, A., Lamola, G., Bertolucci, F., Vallone, F., Di Garbo, A., Chisari, C., Micera, S., et al. (2017) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2017.00076 · Cited by 250
Grimmer, M., Riener, R., Walsh, C. J., & Seyfarth, A. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0458-8 · Cited by 249
Bruni, M. F., Melegari, C., De Cola, M. C., Bramanti, A., Bramanti, P., & Calabrò, R. S. (2018) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.10.048 · Cited by 240
Nilsson, A., Vreede, K., Häglund, V., Kawamoto, H., Sankai, Y., & Borg, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-92 · Cited by 206
Mehrholz, J., & Pohl, M. (2012) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0943 · Cited by 193
The Present and Future of Robotic Technology in Rehabilitation
Laut, J., Porfiri, M., & Raghavan, P. (2016) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-016-0139-0 · Cited by 179
Hobbs, B., & Artemiadis, P. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00019 · Cited by 178
The value of robotic systems in stroke rehabilitation
Masiero, S., Poli, P., Rosati, G., Zanotto, D., Iosa, M., Paolucci, S., & Morone, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.882766 · Cited by 168
Peternel, L., Noda, T., Petrič, T., Ude, A., Morimoto, J., & Babič, J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148942 · Cited by 167
Cao, J., Xie, S. Q., Das, R., & Zhu, G. L. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.005 · Cited by 153
Lloyd, M., Skelton, D. A., Mead, G. E., Williams, B., & van Wijck, F. (2018) · Brain and Behavior · doi:10.1002/brb3.1000 · Cited by 40
Metadata
- Authors
- Hesse, S., Waldner, A., & Tomelleri, C.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2010-06-28
- Volume
- 7
- Issue
- 1
- Pages
- 30-30
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2001873277
- Cited by
- 225
- References
- 22
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.