Comparative inhalation toxicity of multi-wall carbon nanotubes, graphene, graphite nanoplatelets and low surface carbon black
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Background: Carbon nanotubes, graphene, graphite nanoplatelets and carbon black are seemingly chemically identical carbon-based nano-materials with broad technological applications. Carbon nanotubes and carbon black possess different inhalation toxicities, whereas little is known about graphene and graphite nanoplatelets. Methods: In order to compare the inhalation toxicity of the mentioned carbon-based nanomaterials, male Wistar rats were exposed head-nose to atmospheres of the respective materials for 6 hours per day on 5 consecutive days. Target concentrations were 0.1, 0.5, or 2.5 mg/m 3 for multi-wall carbon nanotubes and 0.5, 2.5, or 10 mg/m 3 for graphene, graphite nanoplatelets and low-surface carbon black. Toxicity was determined after end of exposure and after three-week recovery using broncho-alveolar lavage fluid and microscopic examinations of the entire respiratory tract. Results: No adverse effects were observed after inhalation exposure to 10 mg/m 3 graphite nanoplatelets or relatively low specific surface area carbon black. Increases of lavage markers indicative for inflammatory processes started at exposure concentration of 0.5 mg/m 3 for multi-wall carbon nanotubes and 10 mg/m 3 for graphene. Consistent with the changes in lavage fluid, microgranulomas were observed at 2.5 mg/m 3 multi-wall carbon nanotubes and 10 mg/m 3 graphene. In order to evaluate volumetric loading of the lung as the key parameter driving the toxicity, deposited particle volume was calculated, taking into account different methods to determine the agglomerate density. However, the calculated volumetric load did not correlate to the toxicity, nor did the particle surface burden of the lung. Conclusions: The inhalation toxicity of the investigated carbon-based materials is likely to be a complex interaction of several parameters. Until the properties which govern the toxicity are identified, testing by short-term inhalation is the best option to identify hazardous properties in order to avoid unsafe applications or select safer alternatives for a given application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geim, A. K., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1849 · Cited by 39,979 · cited 1×
“in photonics, supercapacitors, or bioapplications [3-5].”
Nonparametric Statistics for the Behavioral Sciences
Guitton, H., & Siegel, S. (1958) · Revue économique · doi:10.2307/3498751 · Cited by 35,245
Novoselov, K. S., Fal′ko, V. I., Colombo, L., Gellert, P. R., Schwab, M. G., & Kim, K. (2012) · Nature · doi:10.1038/nature11458 · Cited by 9,251 · cited 1×
“in photonics, supercapacitors, or bioapplications [3-5].”
IARC Monographs on the Evaluation of Carcinogenic Risks to Humans
Zuckerman, A. J. (1995) · Journal of Clinical Pathology · doi:10.1136/jcp.48.7.691-a · Cited by 8,728
A Multiple Comparison Procedure for Comparing Several Treatments with a Control
Dunnett, C. W. (1955) · Journal of the American Statistical Association · doi:10.1080/01621459.1955.10501294 · Cited by 6,094 · cited 1×
“Dunnett’s test [52,53] was used for simultaneous comparison of all concentration groups with the control group for body weights and body weight changes.”
MethodSimultaneous Statistical Inference
Miller, R. G. (1981) · Springer Series in Statistics · doi:10.1007/978-1-4613-8122-8 · Cited by 5,604
New Tables for Multiple Comparisons with a Control
Dunnett, C. W. (1964) · Biometrics · doi:10.2307/2528490 · Cited by 3,113 · cited 1×
“Dunnett’s test [52,53] was used for simultaneous comparison of all concentration groups with the control group for body weights and body weight changes.”
MethodIARC monographs on the evaluation of carcinogenic risks to humans
Hopkins, J. (1989) · Food and Chemical Toxicology · doi:10.1016/0278-6915(89)90054-9 · Cited by 2,876
Poland, C. A., Duffin, R., Kinloch, I., Maynard, A., Wallace, W. A. H., Seaton, A., Stone, V., Brown, S., MacNee, W., & Donaldson, K. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.111 · Cited by 2,645 · cited 3×
“Many factors determining the toxicity of nanomaterials have been discussed: Structural properties have been discussed as an important factor governing biological effects of nanomaterials, such as structural defects [32,33], fiber length [22,34], aggregation state [18,29,35-37], but also surface properties such as surf…”
BackgroundLam, C.-W. (2003) · Toxicological Sciences · doi:10.1093/toxsci/kfg243 · Cited by 1,991 · cited 1×
“Intratracheal administration of SWCNTs or MWCNTs caused pulmonary inflammation, characterized by changes in cellularity and enzyme activities of BALF and associated microscopic findings like macrophage infiltration, epitheloid granulomas, and fibrotic changes in mice and rats [13-20].”
Background
Cited by
Müller, K., Bugnicourt, E., Latorre, M., Jorda, M., Echegoyen Sanz, Y., Lagaron, J., Miesbauer, O., Bianchin, A., Hankin, S., Bölz, U., et al. (2017) · Nanomaterials · doi:10.3390/nano7040074 · Cited by 746
Toxicity of metal and metal oxide nanoparticles: a review
Sengul, A. B., & Asmatulu, E. (2020) · Environmental Chemistry Letters · doi:10.1007/s10311-020-01033-6 · Cited by 681
Assessment of the toxic potential of graphene family nanomaterials
Guo, X., & Mei, N. (2014) · Journal of Food and Drug Analysis · doi:10.1016/j.jfda.2014.01.009 · Cited by 421
Biomedical Uses for 2D Materials Beyond Graphene: Current Advances and Challenges Ahead
Kurapati, R., Kostarelos, K., Prato, M., & Bianco, A. (2016) · Advanced Materials · doi:10.1002/adma.201506306 · Cited by 417
Physicochemical characteristics of nanomaterials that affect pulmonary inflammation
Braakhuis, H. M., Park, M. V., Gosens, I., De Jong, W. H., & Cassee, F. R. (2014) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-11-18 · Cited by 358
Lung carcinogenicity of inhaled multi-walled carbon nanotube in rats
Kasai, T., Umeda, Y., Ohnishi, M., Mine, T., Kondo, H., Takeuchi, T., Matsumoto, M., & Fukushima, S. (2015) · Particle and Fibre Toxicology · doi:10.1186/s12989-016-0164-2 · Cited by 262
A decision-making framework for the grouping and testing of nanomaterials (DF4nanoGrouping)
Arts, J. H. E., Hadi, M., Irfan, M.-A., Keene, A. M., Kreiling, R., Lyon, D., Maier, M., Michel, K., Petry, T., Sauer, U. G., et al. (2015) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2015.03.007 · Cited by 256
Self-citationLund, A., van der Velden, N. M., Persson, N.-K., Hamedi, M. M., & Müller, C. (2018) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2018.03.001 · Cited by 235
Carbon Nanotubes: An Emerging Drug Carrier for Targeting Cancer Cells
Rastogi, V., Yadav, P., Bhattacharya, S. S., Mishra, A. K., Verma, N., Verma, A., & Pandit, J. K. (2014) · Journal of Drug Delivery · doi:10.1155/2014/670815 · Cited by 212
Rittinghausen, S., Hackbarth, A., Creutzenberg, O., Ernst, H., Heinrich, U., Leonhardt, A., & Schaudien, D. (2014) · Particle and Fibre Toxicology · doi:10.1186/s12989-014-0059-z · Cited by 193
“Similar observations were made by Ma-Hock and co-workers [50], who tested GraphistrengthTM MWCNTs with diameters of 10 to 15 nm and lengths of 1 to 10 μm in a short-term rat inhalation study (6 days with a 3-week post-inhalation period).”
MethodBiomedical applications of the graphene-based materials
Zhang, B., Wang, Y., & Zhai, G. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.12.073 · Cited by 189
A review of toxicity studies on graphene-based nanomaterials in laboratory animals
Ema, M., Gamo, M., & Honda, K. (2017) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2017.01.011 · Cited by 188
Application of short-term inhalation studies to assess the inhalation toxicity of nanomaterials
Landsiedel, R., Ma-Hock, L., Hofmann, T., Wiemann, M., Strauss, V., Treumann, S., Wohlleben, W., Gröters, S., Wiench, K., & van Ravenzwaay, B. (2014) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-11-16 · Cited by 169
“MWCNT quartz (no lung effects up to 10 mg/m3; however systema [35],”
BackgroundResultInfluentialSelf-citationWiemann, M., Vennemann, A., Sauer, U. G., Wiench, K., Ma-Hock, L., & Landsiedel, R. (2016) · Journal of Nanobiotechnology · doi:10.1186/s12951-016-0164-2 · Cited by 152
Self-citationThe asbestos-carbon nanotube analogy: An update
Kane, A. B., Hurt, R. H., & Gao, H. (2018) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2018.06.027 · Cited by 106
“…of commercial forms of graphene, usually produced as few layer graphene or graphite nanoplatelets (reviewed by Sanchez et al., 2012), recent studies suggest that these two dimensional carbon nanomaterials show lower lung toxicity than carbon nanotubes (Ma-Hock et al., 2013; Roberts et al., 2016).”
In vivo effects: Methodologies and biokinetics of inhaled nanomaterials
Oberdörster, G., & Kuhlbusch, T. A. J. (2018) · NanoImpact · doi:10.1016/j.impact.2017.10.007 · Cited by 88
Elliott, J. (2017) · ALTEX · doi:10.14573/altex.1605021 · Cited by 84
Metadata
- Authors
- Ma-Hock, L., Strauss, V., Treumann, S., Küttler, K., Wohlleben, W., Hofmann, T., Gröters, S., Wiench, K., van Ravenzwaay, B., & Landsiedel, R.
- Venue
- Particle and Fibre Toxicology
- Published
- 2013-06-17
- Volume
- 10
- Issue
- 1
- Pages
- 23-23
- ISSN
- 1743-8977 (ISSN-L)
- OpenAlex
- W2131621090
- Cited by
- 202
- References
- 58
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.