Use of silver nanowires to determine thresholds for fibre length-dependent pulmonary inflammation and inhibition of macrophage migration in vitro
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: The objective of this study was to examine the threshold fibre length for the onset of pulmonary inflammation after aspiration exposure in mice to four different lengths of silver nanowires (AgNW). We further examined the effect of fibre length on macrophage locomotion in an in vitro wound healing assay. We hypothesised that exposure to longer fibres causes both increased inflammation and restricted mobility leading to impaired clearance of long fibres from the lower respiratory tract to the mucociliary escalator in vivo. Methods: Nine week old female C57BL/6 strain mice were exposed to AgNW and controls via pharyngeal aspiration. The dose used in this study was equalised to fibre number and based on 50 μg/ mouse for AgNW 14. To examine macrophage migration in vitro a wound healing assay was used. An artificial wound was created in a confluent layer of bone marrow derived macrophages by scraping with a pipette tip and the number of cells migrating into the wound was monitored microscopically. The dose was equalised for fibre number and based on 2.5 μg/cm 2 for AgNW 14. Results: Aspiration of AgNW resulted in a length dependent inflammatory response in the lungs with threshold at a fibre length of 14 μm. Shorter fibres including 3, 5 and 10 μm elicited no significant inflammation. Macrophage locomotion was also restricted in a length dependent manner whereby AgNW in the length of ≥5 μm resulted in impaired motility in the wound closure assay. Conclusion: We demonstrated a 14 μm cut-off length for fibre-induced pulmonary inflammation after aspiration exposure and an in vitro threshold for inhibition of macrophage locomotion of 5 μm. We previously reported a threshold length of 5 μm for fibre-induced pleural inflammation. This difference in pulmonary and pleural fibre- induced inflammation may be explained by differences in clearance mechanism of deposited fibres from the airspaces compared to the pleural space. Inhibition of macrophage migration at long fibre lengths could account for their well-documented long term retention in the lungs compared to short fibres. Knowledge of the threshold length for acute pulmonary inflammation contributes to hazard identification of nanofibres.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poland, C. A., Duffin, R., Kinloch, I., Maynard, A., Wallace, W. A. H., Seaton, A., Stone, V., Brown, S., MacNee, W., & Donaldson, K. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.111 · Cited by 2,645 · cited 2×
“Similar results were obtained from studies on short (<1 μm) and long (>13 μm) carbon nanotubes where the resultant pathophysiological response was compared to short and long amosite asbestos fibres [15-17].”
Self-citationDonaldson, K., Murphy, F. A., Duffin, R., & Poland, C. A. (2010) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-7-5 · Cited by 916
Self-citationCell size of alveolar macrophages: an interspecies comparison.
Krombach, F., Münzing, S., Allmeling, A. M., Gerlach, J. T., Behr, J., & Dörger, M. (1997) · Environmental Health Perspectives · doi:10.1289/ehp.97105s51261 · Cited by 285
Schinwald, A., Murphy, F. A., Prina-Mello, A., Poland, C. A., Byrne, F., Movia, D., Glass, J. R., Dickerson, J. C., Schultz, D. A., Jeffree, C. E., et al. (2012) · Toxicological Sciences · doi:10.1093/toxsci/kfs171 · Cited by 181
Self-citationTranslocation pathways for inhaled asbestos fibers
Miserocchi, G., Sancini, G., Mantegazza, F., & Chiappino, G. (2008) · Environmental Health · doi:10.1186/1476-069x-7-4 · Cited by 181
Looyenga, B. D., Hutchings, D., Cherni, I., Kingsley, C., Weiss, G. J., & MacKeigan, J. P. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030820 · Cited by 120
Cited by
Current characterization methods for cellulose nanomaterials
Foster, E. J., Moon, R. J., Agarwal, U. P., Bortner, M. J., Bras, J., Camarero-Espinosa, S., Chan, K. J., Clift, M. J. D., Cranston, E. D., Eichhorn, S. J., et al. (2018) · Chemical Society Reviews · doi:10.1039/c6cs00895j · Cited by 1,021
Physicochemical characteristics of nanomaterials that affect pulmonary inflammation
Braakhuis, H. M., Park, M. V., Gosens, I., De Jong, W. H., & Cassee, F. R. (2014) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-11-18 · Cited by 358
Pulmonary toxicity of carbon nanotubes and asbestos — Similarities and differences
Donaldson, K., Poland, C. A., Murphy, F. A., MacFarlane, M., Chernova, T., & Schinwald, A. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.014 · Cited by 341
Self-citationNanotoxicity: challenging the myth of nano-specific toxicity
Donaldson, K., & Poland, C. A. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.05.003 · Cited by 221
“also examined the cut-off length in the lung and found this to be larger with a 14 mm threshold for fibre-induced pulmonary inflammation after aspiration exposure and an in vitro threshold for inhibition of macrophage locomotion of 5 mm [69].”
BackgroundSelf-citationIs asbestos still a problem in the world? A current review
Thives, L. P., Ghisi, E., Thives Júnior, J. J., & Vieira, A. S. (2022) · Journal of Environmental Management · doi:10.1016/j.jenvman.2022.115716 · Cited by 118
Metadata
- Authors
- Schinwald, A., Chernova, T., & Donaldson, K.
- Venue
- Particle and Fibre Toxicology
- Published
- 2012-12
- Volume
- 9
- Issue
- 1
- Pages
- 47-47
- ISSN
- 1743-8977 (ISSN-L)
- OpenAlex
- W2155242291
- Cited by
- 80
- References
- 6
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of silver nanowires to determine thresholds for fibre length-dependent pulmonary inflammation and inhibition of macrophage migration in vitro. https://app.cochat.ai/papers/10.1186/1743-8977-9-47
- The paper
- Schinwald, A., Chernova, T., & Donaldson, K. (2012). Use of silver nanowires to determine thresholds for fibre length-dependent pulmonary inflammation and inhibition of macrophage migration in vitro. Particle and Fibre Toxicology. https://doi.org/10.1186/1743-8977-9-47
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.