The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
3D Variation in delineation of head and neck organs at risk
Open accessAbstract
BACKGROUND: Consistent delineation of patient anatomy becomes increasingly important with the growing use of highly conformal and adaptive radiotherapy techniques. This study investigates the magnitude and 3D localization of interobserver variability of organs at risk (OARs) in the head and neck area with application of delineation guidelines, to establish measures to reduce current redundant variability in delineation practice. METHODS: Interobserver variability among five experienced radiation oncologists was studied in a set of 12 head and neck patient CT scans for the spinal cord, parotid and submandibular glands, thyroid cartilage, and glottic larynx. For all OARs, three endpoints were calculated: the Intraclass Correlation Coefficient (ICC), the Concordance Index (CI) and a 3D measure of variation (3D SD). RESULTS: All endpoints showed largest interobserver variability for the glottic larynx (ICC = 0.27, mean CI = 0.37 and 3D SD = 3.9 mm). Better agreement in delineations was observed for the other OARs (range, ICC = 0.32-0.83, mean CI = 0.64-0.71 and 3D SD = 0.9-2.6 mm). Cranial, caudal, and medial regions of the OARs showed largest variations. All endpoints provided support for improvement of delineation practice. CONCLUSIONS: Variation in delineation is traced to several regional causes. Measures to reduce this variation can be: (1) guideline development, (2) joint delineation review sessions and (3) application of multimodality imaging. Improvement of delineation practice is needed to standardize patient treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
Segmentation of organs‐at‐risks in head and neck CT images using convolutional neural networks
Ibragimov, B., & Xing, L. (2017) · Medical Physics · doi:10.1002/mp.12045 · Cited by 502
Vision 20/20: Perspectives on automated image segmentation for radiotherapy
Sharp, G., Fritscher, K. D., Pekar, V., Peroni, M., Shusharina, N., Veeraraghavan, H., & Yang, J. (2014) · Medical Physics · doi:10.1118/1.4871620 · Cited by 375
Vinod, S. K., Jameson, M. G., Min, M., & Holloway, L. C. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.09.009 · Cited by 350
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
Self-citation
Metadata
- Authors
- Brouwer, C. L., Steenbakkers, R. J., van den Heuvel, E., Duppen, J. C., Navran, A., Bijl, H. P., Chouvalova, O., Burlage, F. R., Meertens, H., Langendijk, J. A., & van 't Veld, A. A.
- Venue
- Radiation Oncology
- Published
- 2012-03-13
- Volume
- 7
- Issue
- 1
- Pages
- 32-32
- ISSN
- 1748-717X (ISSN-L)
- OpenAlex
- W2107595635
- Cited by
- 211
- References
- 1
- FWCI
- 8.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Variation in delineation of head and neck organs at risk. https://app.cochat.ai/papers/10.1186/1748-717x-7-32
- The paper
- Brouwer, C. L., Steenbakkers, R. J., van den Heuvel, E., Duppen, J. C., Navran, A., Bijl, H. P., Chouvalova, O., Burlage, F. R., Meertens, H., Langendijk, J. A., & van 't Veld, A. A. (2012). 3D Variation in delineation of head and neck organs at risk. Radiation Oncology. https://doi.org/10.1186/1748-717x-7-32
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.