The effects of a tourniquet used in total knee arthroplasty: a meta-analysis
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The purpose of this research is to evaluate the effects of a tourniquet in total knee arthroplasty (TKA). METHODS: The study was done by randomized controlled trials (RCTs) on the effects of a tourniquet in TKA. All related articles which were published up to June 2013 from Medline, Embase, and Cochrane Central Register of Controlled Trails were identified. The methodological quality of the included studies was assessed by the Physiotherapy Evidence Database (PEDro) scale. The meta-analysis was performed using Cochrane RevMan software version 5.1. RESULTS: Thirteen RCTs that involved a total of 689 patients with 689 knees were included in the meta-analysis, which were divided into two groups. The tourniquet group included 351 knees and the non-tourniquet group included 338 knees. The meta-analysis showed that using a tourniquet in TKA could reduce intraoperative blood loss (weighted mean difference (WMD), -198.21; 95% confidence interval (CI), -279.82 to -116.60; P<0.01) but did not decrease the calculated blood loss (P=0.80), which indicates the actual blood loss. Although TKA with a tourniquet could save the operation time for 4.57 min compared to TKA without a tourniquet (WMD, -4.57; 95% CI, -7.59 to -1.56; P<0.01), it had no clinical significance. Meanwhile, the use of tourniquet could not reduce the possibility of blood transfusion (P>0.05). Postoperative knee range of motion (ROM) in tourniquet group was 10.41° less than that in the non-tourniquet group in early stage (≤ 10 days after surgery) (WMD, -10.41; 95% CI, -16.41 to -4.41; P<0.01). Moreover, the use of a tourniquet increased the risk of either thrombotic events (risk ratio (RR), 5.00; 95% CI, 1.31 to 19.10; P=0.02) or non-thrombotic complications (RR, 2.03; 95% CI, 1.12 to 3.67; P=0.02). CONCLUSIONS: TKA without a tourniquet was superior to TKA with a tourniquet in thromboembolic events and the other related complications. There were no significant differences between the two groups in the actual blood loss. TKA with a tourniquet might hinder patients' early postoperative rehabilitation exercises.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reliability of the PEDro Scale for Rating Quality of Randomized Controlled Trials
Maher, C. G., Sherrington, C., Herbert, R. D., Moseley, A. M., & Elkins, M. (2003) · Physical Therapy · doi:10.1093/ptj/83.8.713 · Cited by 4,808
de Morton, N. A. (2009) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(09)70043-1 · Cited by 2,201
Cited by
Wainwright, T. W., Gill, M., McDonald, D. A., Middleton, R. G., Reed, M., Sahota, O., Yates, P., & Ljungqvist, O. (2020) · Acta Orthopaedica · doi:10.1080/17453674.2019.1683790 · Cited by 805
Enhanced recovery after surgery for major orthopedic surgery: a narrative review
Choi, Y. S., Kim, T. W., Chang, M. J., Kang, S.-B., & Chang, C. B. (2022) · Knee Surgery & Related Research · doi:10.1186/s43019-022-00137-3 · Cited by 83
“The use of tourniquets when performing TKA can generally improve vision by reducing bleeding during surgery [83].”
Background
Metadata
- Authors
- Zhang, W., Li, N., Chen, S., Tan, Y., Al-Aidaros, M., & Chen, L.
- Venue
- Journal of Orthopaedic Surgery and Research
- Published
- 2014-03-06
- Volume
- 9
- Issue
- 1
- Pages
- 13-13
- ISSN
- 1749-799X (ISSN-L)
- OpenAlex
- W2112536023
- Cited by
- 245
- References
- 2
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.