Computational mass spectrometry for small molecules
Open accessThe DOI matches its Crossref record; 203 of the 203 references it cites were found in a registry or an index.
Abstract
: The identification of small molecules from mass spectrometry (MS) data remains a major challenge in the interpretation of MS data. This review covers the computational aspects of identifying small molecules, from the identification of a compound searching a reference spectral library, to the structural elucidation of unknowns. In detail, we describe the basic principles and pitfalls of searching mass spectral reference libraries. Determining the molecular formula of the compound can serve as a basis for subsequent structural elucidation; consequently, we cover different methods for molecular formula identification, focussing on isotope pattern analysis. We then discuss automated methods to deal with mass spectra of compounds that are not present in spectral libraries, and provide an insight into de novo analysis of fragmentation spectra using fragmentation trees. In addition, this review shortly covers the reconstruction of metabolic networks using MS data. Finally, we list available software for different steps of the analysis pipeline.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–203 of 203
Finding Characteristic Substructures for Metabolite Classes
Ludwig, M., Hufsky, F., Elshamy, S., & Böcker, S. (2012) · DROPS (Schloss Dagstuhl – Leibniz Center for Informatics) · doi:10.4230/oasics.gcb.2012.23 · Cited by 7
Self-citationSVM-based spectral matching for metabolite identification
Zhou, B., Cheema, A. K., & Ressom, H. W. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626337 · Cited by 7 · cited 1×
“Zhou et al [94] proposed a support vector machine (SVM)- based spectral matching algorithm to combine multiple similarity measures.”
Hufsky, F., & Böcker, S. (2012) · DROPS (Schloss Dagstuhl – Leibniz Center for Informatics) · doi:10.4230/oasics.gcb.2012.12 · Cited by 5
Self-citation
Cited by
PubChem Substance and Compound databases
Kim, S., Thiessen, P. A., Bolton, E. E., Chen, J., Fu, G., Gindulyte, A., Han, L., He, J., He, S., Shoemaker, B. A., et al. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkv951 · Cited by 5,436
Searching molecular structure databases with tandem mass spectra using CSI:FingerID
Dührkop, K., Shen, H., Meusel, M., Rousu, J., & Böcker, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509788112 · Cited by 1,190
Self-citationSoftware Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics
Blaženović, I., Kind, T., Ji, J., & Fiehn, O. (2018) · Metabolites · doi:10.3390/metabo8020031 · Cited by 757
Schymanski, E. L., Singer, H. P., Slobodnik, J., Ipolyi, I. M., Oswald, P., Krauss, M., Schulze, T., Haglund, P., Letzel, T., Grosse, S., et al. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8681-7 · Cited by 703
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Metadata
- Authors
- Scheubert, K., Hufsky, F., & Böcker, S.
- Venue
- Journal of Cheminformatics
- Published
- 2013-03-01
- Volume
- 5
- Issue
- 1
- Pages
- 12-12
- ISSN
- 1758-2946 (ISSN-L)
- OpenAlex
- W2092818812
- Cited by
- 173
- References
- 203
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.