Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Coincidence imaging of low-abundance yttrium-90 (90Y) internal pair production by positron emission tomography with integrated computed tomography (PET/CT) achieves high-resolution imaging of post-radioembolization microsphere biodistribution. Part 2 analyzes tumor and non-target tissue dose-response by 90Y PET quantification and evaluates the accuracy of tumor 99mTc macroaggregated albumin (MAA) single-photon emission computed tomography with integrated CT (SPECT/CT) predictive dosimetry. METHODS: Retrospective dose quantification of 90Y resin microspheres was performed on the same 23-patient data set in part 1. Phantom studies were performed to assure quantitative accuracy of our time-of-flight lutetium-yttrium-oxyorthosilicate system. Dose-responses were analyzed using 90Y dose-volume histograms (DVHs) by PET voxel dosimetry or mean absorbed doses by Medical Internal Radiation Dose macrodosimetry, correlated to follow-up imaging or clinical findings. Intended tumor mean doses by predictive dosimetry were compared to doses by 90Y PET. RESULTS: Phantom studies demonstrated near-perfect detector linearity and high tumor quantitative accuracy. For hepatocellular carcinomas, complete responses were generally achieved at D70 > 100 Gy (D70, minimum dose to 70% tumor volume), whereas incomplete responses were generally at D70 < 100 Gy; smaller tumors (<80 cm3) achieved D70 > 100 Gy more easily than larger tumors. There was complete response in a cholangiocarcinoma at D70 90 Gy and partial response in an adrenal gastrointestinal stromal tumor metastasis at D70 53 Gy. In two patients, a mean dose of 18 Gy to the stomach was asymptomatic, 49 Gy caused gastritis, 65 Gy caused ulceration, and 53 Gy caused duodenitis. In one patient, a bilateral kidney mean dose of 9 Gy (V20 8%) did not cause clinically relevant nephrotoxicity. Under near-ideal dosimetric conditions, there was excellent correlation between intended tumor mean doses by predictive dosimetry and those by 90Y PET, with a low median relative error of +3.8% (95% confidence interval, -1.2% to +13.2%). CONCLUSIONS: Tumor and non-target tissue absorbed dose quantification by 90Y PET is accurate and yields radiobiologically meaningful dose-response information to guide adjuvant or mitigative action. Tumor 99mTc MAA SPECT/CT predictive dosimetry is feasible. 90Y DVHs may guide future techniques in predictive dosimetry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of Normal Tissue Complication Probability Models in the Clinic
Marks, L. B., Yorke, E. D., Jackson, A., Ten Haken, R. K., Constine, L. S., Eisbruch, A., Bentzen, S. M., Nam, J., & Deasy, J. O. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.07.1754 · Cited by 1,826 · cited 2×
“All results were in keeping with published experiences of external beam radiotherapy [29,30].”
BackgroundResultHo, S., Lau, W. Y., Leung, T. W. T., Chan, M., Johnson, P. J., & Li, A. K. C. (1997) · European Journal of Nuclear Medicine · doi:10.1007/bf01728766 · Cited by 255
Strigari, L., Sciuto, R., Rea, S., Carpanese, L., Pizzi, G., Soriani, A., Iaccarino, G., Benassi, M., Ettorre, G. M., & Maini, C. L. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.075861 · Cited by 239
Cited by
Radioembolization of Hepatic Lesions from a Radiobiology and Dosimetric Perspective
Cremonesi, M., Chiesa, C., Strigari, L., Ferrari, M., Botta, F., Guerriero, F., De Cicco, C., Bonomo, G., Orsi, F., Bodei, L., et al. (2014) · Frontiers in Oncology · doi:10.3389/fonc.2014.00210 · Cited by 178
“DVHs are derived, the degree of non-uniformity analyzed (17, 50, 51), and the EUBED, EUD, EQ2 parameters evaluated.”
BackgroundMethodInfluentialChiesa, C., Mira, M., Maccauro, M., Spreafico, C., Romito, R., Morosi, C., Camerini, T., Carrara, M., Pellizzari, S., Negri, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3068-8 · Cited by 164
“[36].”
Metadata
- Authors
- Kao, Y.-H., Steinberg, J. D., Tay, Y.-S., Lim, G. K., Yan, J., Townsend, D. W., Budgeon, C. A., Boucek, J. A., Francis, R. J., Cheo, T. S., Burgmans, M. C., Irani, F. G., Lo, R. H., Tay, K.-H., Tan, B.-S., Chow, P. K., Satchithanantham, S., Tan, A. E., Ng, D. C., & Goh, A. S.
- Venue
- EJNMMI Research
- Published
- 2013
- Volume
- 3
- Issue
- 1
- Pages
- 57
- ISSN
- 2191-219X (ISSN-L)
- OpenAlex
- W2166106543
- Cited by
- 172
- References
- 3
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres. https://app.cochat.ai/papers/10.1186/2191-219x-3-57
- The paper
- Kao, Y.-H., Steinberg, J. D., Tay, Y.-S., Lim, G. K., Yan, J., Townsend, D. W., Budgeon, C. A., Boucek, J. A., Francis, R. J., Cheo, T. S., Burgmans, M. C., Irani, F. G., Lo, R. H., Tay, K.-H., Tan, B.-S., Chow, P. K., Satchithanantham, S., Tan, A. E., Ng, D. C., & Goh, A. S. (2013). Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres. EJNMMI Research. https://doi.org/10.1186/2191-219x-3-57
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.