Prolonged mechanical ventilation in critically ill patients: epidemiology, outcomes and modelling the potential cost consequences of establishing a regional weaning unit
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Introduction: The number of patients requiring prolonged mechanical ventilation (PMV) is likely to increase. Transferring patients to specialised weaning units may improve outcomes and reduce costs. The aim of this study was to establish the incidence and outcomes of PMV in a UK administrative health care region without a dedicated weaning unit, and model the potential impact of establishing a dedicated weaning unit. Methods: A retrospective cohort study was undertaken using a database of admissions to three intensive care units (ICU) in a UK region from 2002 to 2006. Using a 21 day cut-off to define PMV, incidence was calculated using all ICU admissions and ventilated ICU admissions as denominators. Outcomes for the PMV cohort (mortality and hospital resource use) were compared with the non-PMV cohort. Length of ICU stay beyond 21 days was used to model the effect of establishing a weaning unit in terms of unit occupancy rates, admission refusal rates, and healthcare costs. Results: Out of 8290 ICU admission episodes, 7848 were included in the analysis. Mechanical ventilation was required during 5552 admission episodes, of which 349 required PMV. The incidence of PMV was 4.4 per 100 ICU admissions, and 6.3 per 100 ventilated ICU admissions. PMV patients used 29.1% of all general ICU bed days, spent longer in hospital after ICU discharge than non-PMV patients (median 17 vs 7 days, P < 0.001) and had higher hospital mortality (40.3% vs 33.8%, P = 0.02). For the region, in which about 70 PMV patients were treated each year, a weaning unit with a capacity of three beds appeared most cost efficient, resulting in an occupancy rate of 73%, admission refusal rate at 21 days of 36%, and potential cost saving of £344,000 (€418,000) using UK healthcare tariffs. Conclusions: One in every sixteen ventilated patients requires PMV in our region and this group use a substantial amount of health care resource. Establishing a weaning unit would potentially reduce acute bed occupancy by 8-10% and could reduce overall treatment costs. Restructuring the current configuration of critical care services to introduce weaning units should be considered if the expected increase in PMV incidence occurs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kress, J. P., Pohlman, A. S., O'Connor, M. F., & Hall, J. B. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422002 · Cited by 2,981 · cited 1×
“Advances in clinical practice, such as daily sedation breaks [18], spontaneous breathing trials [19], and weaning protocols [20] may help to reduce the length of MV and potentially reduce the need for establishing a weaning unit.”
BackgroundKirkwood, B. R., & Sterne, J. A. C. (2014) · Bristol Research (University of Bristol) · Cited by 2,820
Girard, T. D., Kress, J. P., Fuchs, B. D., Thomason, J. W., Schweickert, W. D., Pun, B. T., Taichman, D. B., Dunn, J. G., Pohlman, A. S., Kinniry, P. A., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60105-1 · Cited by 2,055 · cited 1×
“Advances in clinical practice, such as daily sedation breaks [18], spontaneous breathing trials [19], and weaning protocols [20] may help to reduce the length of MV and potentially reduce the need for establishing a weaning unit.”
BackgroundManagement of Patients Requiring Prolonged Mechanical Ventilation
MacIntyre, N. R., Epstein, S. K., Carson, S., Scheinhorn, D., Christopher, K., & Muldoon, S. (2005) · Chest · doi:10.1378/chest.128.6.3937 · Cited by 533
Blackwood, B., Alderdice, F., Burns, K., Cardwell, C., Lavery, G., & O'Halloran, P. (2011) · BMJ · doi:10.1136/bmj.c7237 · Cited by 336
Management of Patients Requiring Prolonged Mechanical Ventilation
Low, T., Lin, Y., Law, C.-L., & Lin, C. (2017) · 內科學誌 · doi:10.6314/jimt.2017.28(1).05 · Cited by 305
Long-term Acute Care Hospital Utilization After Critical Illness
Kahn, J. M. (2010) · JAMA · doi:10.1001/jama.2010.761 · Cited by 300 · cited 1×
“A recent study using the Medicare database showed a dramatic increase in the number of patients admitted to LTAC facilities in the US between 1997 and 2006, many of whom will fulfil the criteria for PMV [6].”
MethodIncrease in tracheostomy for prolonged mechanical ventilation in North Carolina, 1993–2002
Cox, C. E., Carson, S. S., Holmes, G. M., Howard, A., & Carey, T. S. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000145232.46143.40 · Cited by 270
Outcomes after Long-Term Acute Care: An Analysis of 133 Mechanically Ventilated Patients
CARSON, S. S., BACH, P. B., BRZOZOWSKI, L., & LEFF, A. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.5.9809002 · Cited by 260 · cited 1×
“Direct comparison with published outcomes from other studies is difficult because most published cohorts had different entry criteria or were selected by admission to a weaning unit [25-29].”
ResultPost-ICU Mechanical Ventilation at 23 Long-term Care Hospitals
Scheinhorn, D. J., Hassenpflug, M. S., Votto, J. J., Chao, D. C., Epstein, S. K., Doig, G. S., Knight, E. B., & Petrak, R. A. (2007) · Chest · doi:10.1378/chest.06-1081 · Cited by 198 · cited 1×
“Direct comparison with published outcomes from other studies is difficult because most published cohorts had different entry criteria or were selected by admission to a weaning unit [25-29].”
Result
Cited by
Mechanical Ventilation Antioxidant Trial
Howe, K. P., Clochesy, J. M., Goldstein, L. S., & Owen, H. (2015) · American Journal of Critical Care · doi:10.4037/ajcc2015335 · Cited by 52
Metadata
- Authors
- Lone, N. I., & Walsh, T. S.
- Venue
- Critical Care
- Published
- 2011-03-27
- Volume
- 15
- Issue
- 2
- Pages
- R102-R102
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2143695244
- Cited by
- 225
- References
- 25
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.