The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Clinical effectiveness of fresh frozen plasma compared with fibrinogen concentrate: a systematic review
Open accessAbstract
Introduction: Haemostatic therapy in surgical and/or massive trauma patients typically involves transfusion of fresh frozen plasma (FFP). Purified human fibrinogen concentrate may offer an alternative to FFP in some instances. In this systematic review, we investigated the current evidence for the use of FFP and fibrinogen concentrate in the perioperative or massive trauma setting. Methods: Studies reporting the outcome (blood loss, transfusion requirement, length of stay, survival and plasma fibrinogen level) of FFP or fibrinogen concentrate administration to patients in a perioperative or massive trauma setting were identified in electronic databases (1995 to 2010). Studies were included regardless of type, patient age, sample size or duration of patient follow-up. Studies of patients with congenital clotting factor deficiencies or other haematological disorders were excluded. Studies were assessed for eligibility, and data were extracted and tabulated. Results: Ninety-one eligible studies (70 FFP and 21 fibrinogen concentrate) reported outcomes of interest. Few were high-quality prospective studies. Evidence for the efficacy of FFP was inconsistent across all assessed outcomes. Overall, FFP showed a positive effect for 28% of outcomes and a negative effect for 22% of outcomes. There was limited evidence that FFP reduced mortality: 50% of outcomes associated FFP with reduced mortality (typically trauma and/or massive bleeding), and 20% were associated with increased mortality (typically surgical and/or nonmassive bleeding). Five studies reported the outcome of fibrinogen concentrate versus a comparator. The evidence was consistently positive (70% of all outcomes), with no negative effects reported (0% of all outcomes). Fibrinogen concentrate was compared directly with FFP in three high-quality studies and was found to be superior for > 50% of outcomes in terms of reducing blood loss, allogeneic transfusion requirements, length of intensive care unit and hospital stay and increasing plasma fibrinogen levels. We found no fibrinogen concentrate comparator studies in patients with haemorrhage due to massive trauma, although efficacy across all assessed outcomes was reported in a number of noncomparator trauma studies. Conclusions: The weight of evidence does not appear to support the clinical effectiveness of FFP for surgical and/or massive trauma patients and suggests it can be detrimental. Perioperatively, fibrinogen concentrate was generally associated with improved outcome measures, although more high-quality, prospective studies are required before any definitive conclusions can be drawn.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Relationship of Blood Product Ratio to Mortality: Survival Benefit or Survival Bias?
Snyder, C. W., Weinberg, J. A., McGwin, G., Melton, S. M., George, R. L., Reiff, D. A., Cross, J. M., Hubbard-Brown, J., Rue, L. W., & Kerby, J. D. (2009) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e318196c3ac · Cited by 384
Cited by
Management of bleeding and coagulopathy following major trauma: an updated European guideline
Spahn, D. R., Bouillon, B., Cerny, V., Coats, T. J., Duranteau, J., Fernández-Mondéjar, E., Filipescu, D., Hunt, B. J., Komadina, R., Nardi, G., et al. (2013) · Critical Care · doi:10.1186/cc12685 · Cited by 977
Self-citationManagement of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Self-citationAlternatives to blood transfusion
Spahn, D. R., & Goodnough, L. T. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60808-9 · Cited by 261
Self-citationGielen, C., Dekkers, O., Stijnen, T., Schoones, J., Brand, A., Klautz, R., & Eikenboom, J. (2014) · Interactive CardioVascular and Thoracic Surgery · doi:10.1093/icvts/ivt506 · Cited by 104
Metadata
- Authors
- Kozek-Langenecker, S., Sørensen, B., Hess, J. R., & Spahn, D. R.
- Venue
- Critical Care
- Published
- 2011-10-14
- Volume
- 15
- Issue
- 5
- Pages
- R239-R239
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2168965844
- Cited by
- 234
- References
- 1
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical effectiveness of fresh frozen plasma compared with fibrinogen concentrate: a systematic review. https://app.cochat.ai/papers/10.1186/cc10488
- The paper
- Kozek-Langenecker, S., Sørensen, B., Hess, J. R., & Spahn, D. R. (2011). Clinical effectiveness of fresh frozen plasma compared with fibrinogen concentrate: a systematic review. Critical Care. https://doi.org/10.1186/cc10488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.