The DOI matches its Crossref record.
Non-invasive ventilation for acute hypoxemic respiratory failure: intubation rate and risk factors
Open accessAbstract
Introduction: We assessed rates and predictive factors of non-invasive ventilation (NIV) failure in patients admitted to the intensive care unit (ICU) for non-hypercapnic acute hypoxemic respiratory failure (AHRF). Methods: This is an observational cohort study using data prospectively collected over a three-year period in a medical ICU of a university hospital. Results: Among 113 patients receiving NIV for AHRF, 82 had acute respiratory distress syndrome (ARDS) and 31 had non-ARDS. Intubation rates significantly differed between ARDS and non-ARDS patients (61% versus 35%, P = 0.015) and according to clinical severity of ARDS: 31% in mild, 62% in moderate, and 84% in severe ARDS (P = 0.0016). In-ICU mortality rates were 13% in non-ARDS, and, respectively, 19%, 32% and 32% in mild, moderate and severe ARDS (P = 0.22). Among patients with moderate ARDS, NIV failure was lower among those having a PaO 2/FiO 2 >150 mmHg (45% vs. 74%, p = 0.04). NIV failure was associated with active cancer, shock, moderate/severe ARDS, lower Glasgow coma score and lower positive end-expiratory pressure level at NIV initiation. Among intubated patients, ICU mortality rate was 46% overall and did not differ according to the time to intubation. Conclusions: With intubation rates below 35% in non-ARDS and mild ARDS, NIV stands as the first-line approach; NIV may be attempted in ARDS patients with a PaO 2/FiO 2 > 150. By contrast, 84% of severe ARDS required intubation and NIV did not appear beneficial in this subset of patients. However, the time to intubation had no influence on mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-Flow Oxygen through Nasal Cannula in Acute Hypoxemic Respiratory Failure
Frat, J.-P., Thille, A. W., Mercat, A., Girault, C., Ragot, S., Perbet, S., Prat, G., Boulain, T., Morawiec, E., Cottereau, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1503326 · Cited by 2,342
Self-citationBellani, G., Laffey, J. G., Pham, T., Madotto, F., Fan, E., Brochard, L., Esteban, A., Gattinoni, L., Bumbasirevic, V., Piquilloud, L., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201606-1306oc · Cited by 667
Patel, B. K., Wolfe, K. S., Pohlman, A. S., Hall, J. B., & Kress, J. P. (2016) · JAMA · doi:10.1001/jama.2016.6338 · Cited by 545
Carteaux, G., Millán-Guilarte, T., De Prost, N., Razazi, K., Abid, S., Thille, A. W., Schortgen, F., Brochard, L., Brun-Buisson, C., & Mekontso Dessap, A. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001379 · Cited by 491
Self-citationDing, L., Wang, L., Ma, W., & He, H. (2020) · Critical Care · doi:10.1186/s13054-020-2738-5 · Cited by 417
Metadata
- Authors
- Thille, A. W., Contou, D., Fragnoli, C., Córdoba-Izquierdo, A., Boissier, F., & Brun-Buisson, C.
- Venue
- Critical Care
- Published
- 2013-11-11
- Volume
- 17
- Issue
- 6
- Pages
- R269-R269
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2052041089
- Cited by
- 243
- References
- 0
- FWCI
- 15.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive ventilation for acute hypoxemic respiratory failure: intubation rate and risk factors. https://app.cochat.ai/papers/10.1186/cc13103
- The paper
- Thille, A. W., Contou, D., Fragnoli, C., Córdoba-Izquierdo, A., Boissier, F., & Brun-Buisson, C. (2013). Non-invasive ventilation for acute hypoxemic respiratory failure: intubation rate and risk factors. Critical Care. https://doi.org/10.1186/cc13103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.