Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Utility of thromboelastography and/or thromboelastometry in adults with sepsis: a systematic review

Open access
Müller, Marcella C, Meijers, Joost CM, Vroom, Margreeth B, Juffermans, Nicole P · 2014 · Critical Care

Abstract

Introduction: Coagulation abnormalities are frequent in sepsis. Conventional coagulation assays, however, have several limitations. A surge of interest exists in the use of point-of-care tests to diagnose hypo- and hypercoagulability in sepsis. We performed a systematic review of available literature to establish the value of rotational thromboelastography (TEG) and thromboelastometry (ROTEM) compared with standard coagulation tests to detect hyper- or hypocoagulability in sepsis patients. Furthermore, we assessed the value of TEG/ROTEM to identify sepsis patients likely to benefit from therapies that interfere with the coagulation system. Methods: MEDLINE, EMBASE, and the Cochrane Library were searched from 1 January 1980 to 31 December 2012. The search was limited to adults, and language was limited to English. Reference lists of retrieved articles were hand-searched for additional studies. Ongoing trials were searched on http://www.controlled-trials.com and http://www.clinicaltrials.gov. Studies addressing TEG/ROTEM measurements in adult patients with sepsis admitted to the ICU were considered eligible. Results: Of 680 screened articles, 18 studies were included, of which two were randomized controlled trials, and 16 were observational cohort studies. In patients with sepsis, results show both hyper- and hypocoagulability, as well as TEG/ROTEM values that fell within reference values. Both hyper- and hypocoagulability were to some extent associated with diffuse intravascular coagulation. Compared with conventional coagulation tests, TEG/ROTEM can detect impaired fibrinolysis, which can possibly help to discriminate between sepsis and systemic inflammatory response syndrome (SIRS). A hypocoagulable profile is associated with increased mortality. The value of TEG/ROTEM to identify patients with sepsis who could possibly benefit from therapies interfering with the coagulation system could not be assessed, because studies addressing this topic were limited. Conclusion: TEG/ROTEM could be a promising tool in diagnosing alterations in coagulation in sepsis. Further research on the value of TEG/ROTEM in these patients is warranted. Given that coagulopathy is a dynamic process, sequential measurements are needed to understand the coagulation patterns in sepsis, as can be detected by TEG/ROTEM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc13721

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 221

Metadata

Authors
Müller, M. C., Meijers, J. C., Vroom, M. B., & Juffermans, N. P.
Venue
Critical Care
Published
2014-02-10
Volume
18
Issue
1
Pages
R30-R30
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2061716238
Cited by
221
References
4
FWCI
3.10
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.