Effect of extracorporeal liver support by MARS and Prometheus on serum cytokines in acute-on-chronic liver failure
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Introduction: Cytokines are believed to play an important role in acute-on-chronic liver failure (ACLF). Extracorporeal liver support systems may exert beneficial effects in ACLF via removal of cytokines. At present, two systems are commercially available, the Molecular Adsorbent Recirculating System (MARS™) and Fractionated Plasma Separation, Adsorption and Dialysis (Prometheus™). The aim of this study was to compare the effects of MARS and Prometheus treatments on serum cytokine levels and their clearances. Methods: Eight patients with ACLF underwent alternating treatments with either MARS or Prometheus in a randomized cross-over design. Thirty-four treatments (17 MARS, 17 Prometheus) were available for analysis. Serum cytokines were measured before and after each treatment, and cytokine clearance was calculated from paired arterial and venous samples and effective plasma flow one hour after the start of treatment. Results: Baseline serum levels of interleukin (IL)-6, IL-8, IL-10, tumor necrosis factor-alpha (TNF-α), and soluble TNF-α receptor 1 were significantly elevated in patients with ACLF. Measurable plasma clearances were detected for all cytokines tested, but no significant changes in serum levels of any cytokine were found after treatments with MARS or Prometheus. In MARS treatments, IL-10 was cleared from plasma more efficiently than IL-6. Clearance of IL-10 was higher in Prometheus than in MARS treatments. Conclusion: Cytokines are cleared from plasma by both MARS and Prometheus, but neither system is able to change serum cytokine levels. This discrepancy is probably due to a high rate of cytokine production in patients with ACLF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674
Transection of the oesophagus for bleeding oesophageal varices
Pugh, R. N. H., Murray-Lyon, I. M., Dawson, J. L., Pietroni, M. C., & Williams, R. (1973) · Journal of British Surgery · doi:10.1002/bjs.1800600817 · Cited by 7,941 · cited 1×
“To assess severity of liver disease, Child-Pugh score and model for end-stage liver disease (MELD) score were calculated at baseline [27,28].”
Method
Cited by
Sarin, S. K., Kedarisetty, C. K., Abbas, Z., Amarapurkar, D., Bihari, C., Chan, A. C. Y., Chawla, Y. K., Dokmeci, A. K., Garg, H., Ghazinyan, H., et al. (2014) · Hepatology International · doi:10.1007/s12072-014-9580-2 · Cited by 1,481
“cutoff levels of jaundice, varying from a serum bilirubin of 6–20 mg/dl [37–39, 43].”
Sarin, S. K., Kumar, A., Almeida, J. A., Chawla, Y. K., Fan, S. T., Garg, H., de Silva, H. J., Hamid, S. S., Jalan, R., Komolmit, P., et al. (2009) · Hepatology International · doi:10.1007/s12072-008-9106-x · Cited by 763
Acute-on chronic liver failure
Jalan, R., Gines, P., Olson, J. C., Mookerjee, R. P., Moreau, R., Garcia-Tsao, G., Arroyo, V., & Kamath, P. S. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.06.026 · Cited by 646
Stadlbauer, V., Mookerjee, R. P., Hodges, S., Wright, G. A. K., Davies, N. A., & Jalan, R. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.02.015 · Cited by 288
Self-citationArtificial liver support systems: what is new over the last decade?
García Martínez, J. J., & Bendjelid, K. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0453-z · Cited by 137
Metadata
- Authors
- Stadlbauer, V., Krisper, P., Aigner, R., Haditsch, B., Jung, A., Lackner, C., & Stauber, R. E.
- Venue
- Critical Care
- Published
- 2006-12-07
- Volume
- 10
- Issue
- 6
- Pages
- R169-R169
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W1492766858
- Cited by
- 138
- References
- 2
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.