Determinants of tracheostomy decannulation: an international survey
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Although tracheostomy is probably the most common surgical procedure performed on critically ill patients, it is unknown when a tracheostomy tube can be safely removed. Methods: We performed a cross-sectional survey of physicians and respiratory therapists with expertise in the management of tracheostomized patients at 118 medical centers to characterize contemporary opinions about tracheostomy decannulation practice and to define factors that influence these practices. Results: We surveyed 309 clinicians, of whom 225 responded (73%). Clinicians rated patient level of consciousness, ability to tolerate tracheostomy tube capping, cough effectiveness, and secretions as the most important factors in the decision to decannulate a patient. Decannulation failure was defined as the need to reinsert an artificial airway within 48 hours (45% of respondents) to 96 hours (20% of respondents) of tracheostomy removal, and 2% to 5% was the most frequent recommendation for an acceptable recannulation rate (44% of respondents). In clinical scenarios, clinicians who worked in chronic care facilities (30%) were less likely to recommend decannulation than clinicians who worked in weaning (47%), rehabilitation (53%), or acute care (55%) facilities (p = 0.015). Patients were most likely to be recommended for decannulation if they were alert and interactive (odds ratio [OR] 4.76, 95% confidence interval [CI] 3.27 to 6.90; p < 0.001), had a strong cough (OR 3.84, 95% CI 2.66 to 5.54; p < 0.001), had scant thin secretions (OR 2.23, 95% CI 1.56 to 3.19; p < 0.001), and required minimal supplemental oxygen (OR 2.04, 95% CI 1.45 to 2.86; p < 0.001). Conclusion: Patient level of consciousness, cough effectiveness, secretions, and oxygenation are important determinants of clinicians' tracheostomy decannulation opinions. Most surveyed clinicians defined decannulation failure as the need to reinsert an artificial airway within 48 to 96 hours of planned tracheostomy removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
One-Year Outcomes in Survivors of the Acute Respiratory Distress Syndrome
Herridge, M. S., Cheung, A. M., Tansey, C. M., Matte-Martyn, A., Diaz-Granados, N., Al-Saidi, F., Cooper, A. B., Guest, C. B., Mazer, C. D., Mehta, S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022450 · Cited by 2,334 · cited 1×
“To complicate matters, the long-term management of tracheostomized patients often is fragmented between different health care settings and providers because recovery from critical illness takes months [ 18 ].”
BackgroundFeinstein, A. R. (1987) · doi:10.2307/j.ctt1xp3vbc · Cited by 538
Metadata
- Authors
- Stelfox, H. T., Crimi, C., Berra, L., Noto, A., Schmidt, U., Bigatello, L. M., & Hess, D.
- Venue
- Critical Care
- Published
- 2008-02-26
- Volume
- 12
- Issue
- 1
- Pages
- R26-R26
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2085427753
- Cited by
- 180
- References
- 2
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.