CoChat

Mechanical ventilation with high tidal volume induces inflammation in patients without lung disease

Open access
Pinheiro de Oliveira, Roselaine, Hetzel, Marcio Pereira, dos Anjos Silva, Mauro, Dallegrave, Daniele, Friedman, Gilberto · 2010 · Critical Care
Cited by 137

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Introduction: Mechanical ventilation (MV) with high tidal volumes may induce or aggravate lung injury in critical ill patients. We compared the effects of a protective versus a conventional ventilatory strategy, on systemic and lung production of tumor necrosis factor-α (TNF-α) and interleukin-8 (IL-8) in patients without lung disease. Methods: Patients without lung disease and submitted to mechanical ventilation admitted to one trauma and one general adult intensive care unit of two different university hospitals were enrolled in a prospective randomized-control study. Patients were randomized to receive MV either with tidal volume (V T) of 10 to 12 ml/kg predicted body weight (high V T group) (n = 10) or with V T of 5 to 7 ml/kg predicted body weight (low V T group) (n = 10) with an oxygen inspiratory fraction (FIO 2) enough to keep arterial oxygen saturation >90% with positive end-expiratory pressure (PEEP) of 5 cmH 2 O during 12 hours after admission to the study. TNF-α and IL-8 concentrations were measured in the serum and in the bronchoalveolar lavage fluid (BALF) at admission and after 12 hours of study observation time. Results: Twenty patients were enrolled and analyzed. At admission or after 12 hours there were no differences in serum TNF-α and IL-8 between the two groups. While initial analysis did not reveal significant differences, standardization against urea of logarithmic transformed data revealed that TNF-α and IL-8 levels in bronchoalveolar lavage (BAL) fluid were stable in the low V T group but increased in the high V T group (P = 0.04 and P = 0.03). After 12 hours, BALF TNF-α (P = 0.03) and BALF IL-8 concentrations (P = 0.03) were higher in the high V T group than in the low V T group. Conclusions: The use of lower tidal volumes may limit pulmonary inflammation in mechanically ventilated patients even without lung injury. Trial Registration: Clinical Trial registration: NCT00935896

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc8919

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 137

Metadata

Authors
Pinheiro de Oliveira, R., Hetzel, M. P., dos Anjos Silva, M., Dallegrave, D., & Friedman, G.
Venue
Critical Care
Published
2010-03-18
Volume
14
Issue
2
Pages
R39-R39
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2098073251
Cited by
137
References
3
FWCI
9.84
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.