The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Central venous O2 saturation and venous-to-arterial CO2 difference as complementary tools for goal-directed therapy during high-risk surgery
Open accessAbstract
Introduction: Central venous oxygen saturation (ScvO 2) is a useful therapeutic target in septic shock and high-risk surgery. We tested the hypothesis that central venous-to-arterial carbon dioxide difference (P(cv-a)CO 2), a global index of tissue perfusion, could be used as a complementary tool to ScvO 2 for goal-directed fluid therapy (GDT) to identify persistent low flow after optimization of preload has been achieved by fluid loading during high-risk surgery. Methods: This is a secondary analysis of results obtained in a study involving 70 adult patients (ASA I to III), undergoing major abdominal surgery, and treated with an individualized goal-directed fluid replacement therapy. All patients were managed to maintain a respiratory variation in peak aortic flow velocity below 13%. Cardiac index (CI), oxygen delivery index (DO 2 i), ScvO 2, P(cv-a)CO 2 and postoperative complications were recorded blindly for all patients. Results: A total of 34% of patients developed postoperative complications. At baseline, there was no difference in demographic or haemodynamic variables between patients who developed complications and those who did not. In patients with complications, during surgery, both mean ScvO 2 (78 ± 4 versus 81 ± 4%, P = 0.017) and minimal ScvO 2 (minScvO 2) (67 ± 6 versus 72 ± 6%, P = 0.0017) were lower than in patients without complications, despite perfusion of similar volumes of fluids and comparable CI and DO 2 i values. The optimal ScvO 2 cut-off value was 70.6% and minScvO 2 < 70% was independently associated with the development of postoperative complications (OR = 4.2 (95% CI: 1.1 to 14.4), P = 0.025). P(cv-a)CO 2 was larger in patients with complications (7.8 ± 2 versus 5.6 ± 2 mmHg, P < 10-6). In patients with complications and ScvO 2 ≥71%, P(cv-a)CO 2 was also significantly larger (7.7 ± 2 versus 5.5 ± 2 mmHg, P < 10-6) than in patients without complications. The area under the receiver operating characteristic (ROC) curve was 0.785 (95% CI: 0.74 to 0.83) for discrimination of patients with ScvO 2 ≥71% who did and did not develop complications, with 5 mmHg as the most predictive threshold value. Conclusions: ScvO 2 reflects important changes in O 2 delivery in relation to O 2 needs during the perioperative period. A P(cv-a)CO 2 < 5 mmHg might serve as a complementary target to ScvO 2 during GDT to identify persistent inadequacy of the circulatory response in face of metabolic requirements when an ScvO 2 ≥71% is achieved. Trial registration: Clinicaltrials.gov Identifier: NCT00852449.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Cited by
Cecconi, M., Corredor, C., Arulkumaran, N., Abuella, G., Ball, J., Grounds, R. M., Hamilton, M., & Rhodes, A. (2012) · Critical Care · doi:10.1186/cc11823 · Cited by 339
Perioperative fluid therapy: a statement from the international Fluid Optimization Group
Navarro, L. H. C., Bloomstone, J. A., Auler, J. O. C., Cannesson, M., Rocca, G. D., Gan, T. J., Kinsky, M., Magder, S., Miller, T. E., Mythen, M., et al. (2015) · Perioperative Medicine · doi:10.1186/s13741-015-0014-z · Cited by 298
Monitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
Self-citationFerreira, F. M., Araujo, D. D., Dantas, G. M., Cunha, L. C. C., Zeferino, S. P., & Galas, F. B. (2025) · Brazilian Journal of Anesthesiology (English Edition) · doi:10.1016/j.bjane.2025.844614 · Cited by 5
Metadata
- Authors
- Futier, E., Robin, E., Jabaudon, M., Guerin, R., Petit, A., Bazin, J.-E., Constantin, J.-M., & Vallet, B.
- Venue
- Critical Care
- Published
- 2010-10-29
- Volume
- 14
- Issue
- 5
- Pages
- R193-R193
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2125766623
- Cited by
- 172
- References
- 1
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.