Mass spectrometry-based proteomics as an emerging tool in clinical laboratories
Open accessThe DOI matches its Crossref record; 315 of the 315 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS)-based proteomics have been increasingly implemented in various disciplines of laboratory medicine to identify and quantify biomolecules in a variety of biological specimens. MS-based proteomics is continuously expanding and widely applied in biomarker discovery for early detection, prognosis and markers for treatment response prediction and monitoring. Furthermore, making these advanced tests more accessible and affordable will have the greatest healthcare benefit. This review article highlights the new paradigms MS-based clinical proteomics has created in microbiology laboratories, cancer research and diagnosis of metabolic disorders. The technique is preferred over conventional methods in disease detection and therapy monitoring for its combined advantages in multiplexing capacity, remarkable analytical specificity and sensitivity and low turnaround time. Despite the achievements in the development and adoption of a number of MS-based clinical proteomics practices, more are expected to undergo transition from bench to bedside in the near future. The review provides insights from early trials and recent progresses (mainly covering literature from the NCBI database) in the application of proteomics in clinical laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., & Jemal, A. (2020) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21590 · Cited by 20,444
Siegel, R. L., Miller, K. D., Fuchs, H. E., & Jemal, A. (2022) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21708 · Cited by 17,196 · cited 2×
“…discovery of biological pathways, integrations with available genomics/transcriptomics profiles, appropriate classification of risk groups, treatment selection, therapy monitoring and prognosis in oncology clinic, which resulted in a gradual reduction in cancer mortality rates [15, 28, 245–247].”
BackgroundSiegel, R. L., Miller, K. D., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21442 · Cited by 16,579
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
Universal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352 · cited 1×
“Some of the recent developments in clinical proteomics sample preparation include filter aided sample preparation (FASP) [69, 70], MStern [71], suspension trapping (S-trap) [72, 73], the solid-phase-enhanced sample preparation (SP3) [74–77] and the in-StageTip (iST) [78].”
BackgroundDouble-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/5174 · Cited by 8,161
In situ click chemistry generation of cyclooxygenase-2 inhibitors
Bhardwaj, A., Kaur, J., Wuest, M., & Wuest, F. (2017) · Nature Communications · doi:10.1038/s41467-016-0009-6 · Cited by 7,448
U1 snRNP regulates cancer cell migration and invasion in vitro
Oh, J.-M., Venters, C. C., Di, C., Pinto, A. M., Wan, L., Younis, I., Cai, Z., Arai, C., So, B. R., Duan, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13993-7 · Cited by 7,157
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Research works printed but not linked: 23
- Rostaing L, et al. Falsely elevated whole-blood tacrolimus concentrations in a kidney‐transplant patient: potential hazards. Transpl Int. 2010;23(2):227–30. · doi:10.1111/j.1432-2277.2009.00965.x
- Hamdan MH. Cancer biomarkers: analytical techniques for discovery. John Wiley & Sons; 2007. · doi:10.1002/047011312x
- Satoh M, Nomura F. Applications of mass spectrometry in clinical chemistry. Med Mass Spectrom. 2019;3(1):2–10.
- Yoshimura K, et al. Development of non-proximate probe electrospray ionization for real-time analysis of living animal. Mass Spectrom. 2015;3(SpecialIssue3):S0048–8. · doi:10.5702/massspectrometry.s0048
- Faron ML, et al. Multicenter evaluation of the Bruker MALDI Biotyper CA System for the identification of clinical aerobic gram-negative bacterial isolates. PLoS ONE. 2015;10(11):e0141350. · doi:10.1371/journal.pone.0141350
- Yang H, et al. Mass Spectrometry Imaging of Microbes. Mass Spectrom Lett. 2020;11(3):41–51.
- Wu F, Zhong F, He F. Microbial proteomics: approaches, advances, and applications. J Bioinf Proteom Imaging Anal. 2016;2(1):85–91.
- Cox CR, Voorhees KJ. Bacterial identification by Mass Spectrometry, Detection of Chemical, Biological, Radiological and Nuclear Agents for the Prevention of Terrorism. 2014, Springer. 115–31. · doi:10.1007/978-94-017-9238-7_8
- Haigh J, et al. Rapid identification of bacteria from bioMerieux BacT/ALERT blood culture bottles by MALDI-TOF MS. Br J Biomed Sci. 2013;70(4):149–55. · doi:10.1080/09674845.2013.11669949
- Guembe M et al. Can MALDI-TOF mass spectrometry be used with intravascular catheters? Enfermedades Infecciosas y Microbiología Clínica, 2014. 32(6): p. 372–4. · doi:10.1016/j.eimc.2014.01.011
- Kitagawa K, et al. Improved bacterial identification directly from urine samples with matrix-assisted laser desorption/ionization time‐of‐flight mass spectrometry. J Clin Lab Anal. 2018;32(3):e22301. · doi:10.1002/jcla.22301
- El-Sadek WAE-L. Matrix-assisted laser desorption ionization-time of Flight Mass Spectrometry (MALDI-TOF MS) for the identification of Bacteria causing urinary tract infections. Egypt J Med Microbiol. 2021;30(4):103–12. · doi:10.21608/ejmm.2021.197468
- Dierig A, Frei R, Egli A. The fast route to microbe identification: matrix assisted laser desorption/ionization—time of flight mass spectrometry (MALDI-TOF MS) The Pediatric infectious disease journal, 2015. 34(1): p. 97–9. · doi:10.1097/inf.0000000000000601
- Aleshukina A, et al. Mass spectrometric study of antibiotic resistance of S. aureus and P. aeruginosa using the MALDIquant package. Int J Infect Dis. 2022;116:S12. · doi:10.1016/j.ijid.2021.12.028
- Peng J, et al. Sensitive and rapid detection of viruses associated with hand foot and mouth disease using multiplexed MALDI-TOF analysis. J Clin Virol. 2013;56(2):170–4. · doi:10.1016/j.jcv.2012.10.020
- Zürcher S, et al. Sensitive and rapid detection of ganciclovir resistance by PCR based MALDI-TOF analysis. J Clin Virol. 2012;54(4):359–63. · doi:10.1016/j.jcv.2012.04.019
- Amiri-Eliasi B, Fenselau C. Characterization of protein biomarkers desorbed by MALDI from whole fungal cells. Anal Chem. 2001;73(21):5228–31. · doi:10.1021/ac010651t
- Packeu A, et al. Fast and accurate identification of dermatophytes by matrix-assisted laser desorption ionization–time of flight mass spectrometry: validation in the clinical laboratory. J Clin Microbiol. 2014;52(9):3440–3. · doi:10.1128/jcm.01428-14
- Bai YH, et al. A novel Tumor-Suppressor, CDH18, inhibits Glioma Cell Invasiveness Via UQCRC2 and correlates with the prognosis of Glioma Patients. Cell Physiol Biochem. 2018;48(4):1755–70. · doi:10.1159/000492317
- Gillet LC, et al. Targeted data extraction of the MS/MS Spectra generated by Data-independent Acquisition: a New Concept for consistent and Accurate Proteome Analysis*. Volume 11. Molecular & Cellular Proteomics; 2012. 6O111.016717. · DOI · Paper page
- Richard E, et al. Proteomics as Applied to inherited metabolic Diseases. Curr Proteomics. 2009;6(3):140–53. · DOI
- Lynch KL. Accreditation and quality assurance for clinical liquid Chromatography–Mass spectrometry laboratories. Clin Lab Med. 2018;38(3):515–26. · doi:10.1016/j.cll.2018.05.002
- Dickerson JA, et al. Design and implementation of software for automated quality control and data analysis for a complex LC/MS/MS assay for urine opiates and metabolites. Clin Chim Acta. 2013;415:290–4. · doi:10.1016/j.cca.2012.10.055
Cited by
Kirsher, D. Y., Chand, S., Phong, A., Nguyen, B., Szoke, B. G., & Ahadi, S. (2025) · Communications Chemistry · doi:10.1038/s42004-025-01665-1 · Cited by 111
“The MS-based platforms continued to show higher CVs than af fi nity platforms, except for MS-IS Targeted that had comparable precision to the af fi nity platforms (SupplementaryData1).”
Influential
Metadata
- Authors
- Birhanu, A. G.
- Venue
- Clinical Proteomics
- Published
- 2023-08-26
- Volume
- 20
- Issue
- 1
- Pages
- 32-32
- ISSN
- 1542-6416 (ISSN-L)
- 1559-0275
- OpenAlex
- W4386195889
- Cited by
- 220
- References
- 315
- FWCI
- 19.31
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.