CoChat

Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger

Open access
Riegel, Marcel, Haist-Gulde, Brigitte, Sacher, Frank · 2023 · Environmental Sciences Europe

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index; none of the 13 sources its claims cite is checked for support yet.

Abstract

AbstractLaboratory tests and column tests were carried out in a waterwoks to investigate the removal of short- and long-chain PFAS using activated carbon filtration and ion exchange treatment. For all adsorbents, the sorption affinity of short-chain per- and polyfluoroalkyl carboxylic acids (PFCA) was significantly lower than that of long-chain PFAS or short-chain per- and polyfluoroalkyl sulfonic acids (PFSA). In the PFAS-polluted groundwater matrix, the short-chain PFCA PFBA and PFPeA could only be sufficiently removed with activated carbon over short run times of 6000 and 11,000 bed volumes (BV), respectively. Longer PFCA with a chain length of C6 or more were removed over longer run times.The removal of short-chain PFCA using ion exchange media could also only be achieved over relatively short run times of 5000 BV for PFBA, 10,000BV for PFPeA and 18,000 BV for PFHxA. These are sometimes significantly longer than those of activated carbon. Due to the higher material costs for ion exchange media, there are nevertheless no lower operating costs when the ion exchangers are used in single-use mode. However, ion exchangers can be regenerated and then reused which can result in economic advantages compared to activated carbon filtration. However, for the extensive regeneration, especially for the elution of the long-chain PFAS, the additional use of ethanol is needed in the process. In contrast, the short-chain PFBA and PFPeA can be extracted without organic solvent from a weakly basic ion exchanger.

Overview

CoChat Summary

TL;DR

This study compares granular activated carbon (GAC) and anion exchange (IEX) for removing short- and long-chain PFAS from drinking water, using batch isotherms and field column tests with PFAS-contaminated groundwater. Short-chain perfluoroalkyl carboxylic acids (PFCA), especially PFBA and PFPeA, broke through much earlier than long-chain PFAS, and IEX regeneration required ethanol-containing regenerants for extensive PFAS elution.

Key findings

  • Sorption affinity increased with PFAS chain length and was higher for sulfonates than carboxylates. GAC order: PFOA > PFHxA > PFPeA > PFBA; IEX K6362 order: PFOS > PFHxS > PFBS ≈ PFOA > PFHpA > PFHxA > PFPeA > PFBA.
  • In PFAS-contaminated groundwater, GAC-CC showed 10% breakthrough at 6000 BV for PFBA, 11,000 BV for PFPeA, 16,000 BV for PFHxA, 20,000 BV for PFHpA, and 23,000 BV for PFOA; corresponding GAC loadings were 2.4, 17, 21, 11, and 29 µg/g. IEX D5706 showed 10% breakthrough at 4000 BV for PFBA, 10,000 BV for PFPeA, 25,000 BV for PFHxA, and >50,000 BV for PFHpA and PFOA (Table 8).
  • Standard regenerants (NaOH, HCl, NaCl, Na₂SO₄, Na₂CO₃) gave minor or no regeneration for PFHxA, PFHpA, and PFOA; PFPeA and PFBA were more easily extracted from WBA MP62. Complete extraction of PFCA from IEX A532E used 1 M NaCl in 45%/55% ethanol/water, and WBA D5706 regeneration was highest with 0.5 M HCl in 45% ethanol.
  • In column regeneration, the fourth regeneration with 6 BV of 1 M HCl in 45% ethanol almost completely regenerated all C4–C8 PFCA; the regenerate had PFPeA, PFHxA, PFHpA, and PFOA concentrations 3500–6000 times higher than the contaminated groundwater. Separation factors with 10 BV regenerate were 100 for PFPrA, 400 for PFBA, 1000 for PFPeA, 2500 for PFHxA, and >5000 for PFHpA and PFOA.
  • Single-use IEX was not more cost-effective than GAC: for PFHxA, D5706 had more than twice the adsorption capacity of GAC-CC before breakthrough, but specific consumable material costs were 20 cent/m³ versus 11 cent/m³. With regeneration, D5706 material costs were lower than GAC-CC after two adsorption/regeneration cycles for PFHpA and PFHxA, and after five cycles for PFPeA.

Methods

  • Batch equilibrium experiments used five GAC types and six basic anion exchange media. GAC isotherms used demineralized water spiked with PFBA, PFPeA, PFHxA, and PFOA at 6 µg/L each, 24 h contact, and Freundlich fitting. IEX isotherms used tap water spiked with eight PFAS (PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFBS, PFHxS, PFOS) at 100 µg/L each, pH 7.0 ± 0.3, at least 60 h equilibration, and Langmuir fitting.
  • Field column experiments were carried out at a waterworks in Southern Germany receiving PFAS-contaminated groundwater, primarily PFPeA at 0.74 µg/L and PFHxA at 0.62 µg/L. GAC was tested with the Granular Carbon Selection Test (GCS) and a pilot adsorber at 8 m/h; IEX pilot columns used 8 L resin, 10–25 BV/h, EBCT 2.4–6 min, and filtration velocities of 10–25 m/h.
  • PFAS were analyzed by HPLC-MS/MS according to DIN 38407-42, with isotope-labelled internal standards and external calibration in tap water; solid-phase concentrations were calculated by mass balance.

Limitations

  • The paper states that GCS test data should not be upscaled and should only be used for adsorbent comparison because the high filtration velocity and low bed depth produce breakthrough after around three weeks and curve shapes that differ from full-scale data.
  • The paper states that the cost comparison refers solely to material costs; IEX use would also incur costs for regeneration agents, disposal or further treatment of PFAS-containing regenerate, transport, and further operation, and detailed cost estimation requires further investigations including GAC reactivation.
  • Evident from the text: IEX breakthrough values are inconsistent between the abstract and Table 8/text (e.g., PFBA 5000 BV in the abstract vs 4000 BV in Table 8; PFHxA 18,000 BV in the abstract vs 25,000 BV in Table 8). Also, batch IEX experiments used tap water spiked at 100 µg/L per PFAS, much higher than the groundwater concentrations (<1 µg/L), so batch-derived affinities may not fully represent field behavior.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s12302-023-00716-5

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Adsorption isotherms for PFAS in double-log depiction (matrix: demineralized water; multicomponent system, initial concentration: 6 µg/L each compound; AC: AC-bit1 pulverised; contact time: 24 h)
Fig. 1 Adsorption isotherms for PFAS in double-log depiction (matrix: demineralized water; multicomponent system, initial concentration: 6 µg/L each compound; AC: AC-bit1 pulverised; contact time: 24 h)CC-BY · From the PDF
Fig. 2 Isotherms of the sorption of different PFAS onto IEX K6362 (matrix: tap water)
Fig. 2 Isotherms of the sorption of different PFAS onto IEX K6362 (matrix: tap water)CC-BY · From the PDF
Fig. 3 Isotherms of the sorption of PFPeA onto different ion exchangers (matrix: tap water)
Fig. 3 Isotherms of the sorption of PFPeA onto different ion exchangers (matrix: tap water)CC-BY · From the PDF
Fig. 4 Normalised breakthrough (c/c 0 ) of PFBA and PFOA during granular carbon selection test (GCS test) for different GAC types
Fig. 4 Normalised breakthrough (c/c 0 ) of PFBA and PFOA during granular carbon selection test (GCS test) for different GAC typesCC-BY · From the PDF
Fig. 5 Normalised breakthrough curves of PFAS in the contaminated groundwater for GAC-CC (bed depth: 1 m, filtration velocity 7.5 m/h)
Fig. 5 Normalised breakthrough curves of PFAS in the contaminated groundwater for GAC-CC (bed depth: 1 m, filtration velocity 7.5 m/h)CC-BY · From the PDF
Fig. 6 Throughput achieved at a 100% breakthrough for PFBA (matrix: PFAS-polluted groundwater, GAC-CC)
Fig. 6 Throughput achieved at a 100% breakthrough for PFBA (matrix: PFAS-polluted groundwater, GAC-CC)CC-BY · From the PDF
Fig. 8 Normalised breakthrough curves of PFPrA for different IEX
Fig. 8 Normalised breakthrough curves of PFPrA for different IEXCC-BY · From the PDF
Fig. 7 Normalised breakthrough curves of PFAS from a real groundwater contamination for IEX D5706, regeneration number 1:3 BV of 1 M NaCl, regeneration number 2 and number 3:3 BV of 1 M NaCl in 45% ethanol, regeneration number 4: 6 BV of 1 M HCl in 45% ethanol
Fig. 7 Normalised breakthrough curves of PFAS from a real groundwater contamination for IEX D5706, regeneration number 1:3 BV of 1 M NaCl, regeneration number 2 and number 3:3 BV of 1 M NaCl in 45% ethanol, regeneration number 4: 6 BV of 1 M HCl in 45% ethanolCC-BY · From the PDF
Fig. 9 Regenerated PFCA content using different regeneration agents
Fig. 9 Regenerated PFCA content using different regeneration agentsCC-BY · From the PDF
Image 10
CC-BY · From the PDF
Fig. 11 Specific material costs for the elimination of PFPeA (black), PFHxA (dark grey) and PFHpA (light grey) as a function of the number of adsorption and regeneration cycles
Fig. 11 Specific material costs for the elimination of PFPeA (black), PFHxA (dark grey) and PFHpA (light grey) as a function of the number of adsorption and regeneration cyclesCC-BY · From the PDF
Fig. 10 Operation time and specific material costs per ­ m 3 treated water for one-time use of adsorbents
Fig. 10 Operation time and specific material costs per ­ m 3 treated water for one-time use of adsorbentsCC-BY · From the PDF

Verification

Claims the paper makes

0 Valid · 1 Not valid · 8 Not checked · 84 Own results and interpretations

58 more claims

Create a free account to see all 93 claims and to verify the 1 reference still open.

See all claims — free account
  • It may state two separate claims as one. 24
  • Probably not a substantial claim. 10

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 22 references

Research works printed but not linked: 10

  1. Cornelsen M (2015) Neues verfahren zur entfernung von per- und polyfluorierten chemikalien aus komplex belasteten wässern (new process for removing perfluorinated and polyfluorinated chemicals from complex contaminated waters). gwf-Wasser Abwasser 9:918–925
  2. EC: European commission 2006 directive 2006/122/EC of the European parliament and of the council of 12 December 2006 amending for the 30th time council directive 76/769/EEC on the approximation of the laws, regulations and administrative provisions of the Member States relating to restrictions on the marketing and use of certain dangerous substances and preparations (perfluorooctane sulfonates). In: Official journal of the European Union 372/32
  3. Haist-Gulde B, Baldauf G (2014) Kornaktivkohlen zur Trinkwasseraufbereitung (granular activated carbons for drinking water treatment). Energie-wasser-praxis 6:50–55
  4. Haist-Gulde B, Baldauf G, Brauch H-J (1993) Removal of pesticides from raw waters. Water Supply 11:159–168
  5. Lutze H. 2013 Sulfate radical based oxidation in water treatment. PhD thesis, Universität Duisburg-Essen, Germany
  6. Riegel M, Sacher F, Lange FT (2017) Aufbereitungstechnische entfernung kurzkettiger perfluorierter chemikalien (PFC) durch anionenaustauscher (removal of short-chain perfluorinated chemicals (PFC) by anion exchangers). Vom Wasser 115(2):57–61
  7. Stockholm convention. Ninth meeting of the conference of the parties to the stockholm convention. Joint press release with the Ministry of the Environment, 14 May 2019. https://www.meti.go.jp/english/press/2019/0514_001.html
  8. Sontheimer H, Crittenden JC, Summers RS (1988) Activated carbon for water treatment. DVGW-Forschungstelle, Karlsruhe
  9. Szabo J, Hall J, Magnuson M, Panguluri S, Meiners G (2017) Treatment of perfluorinated alkyl substances in wash water using granular acitvated carbon and mixed-media, report EPA/600/R-17/175. US-EPA, Cincinnati, USA
  10. Trenkle A (2015) Transfer von poly- und perfluorierten Chemikalien (PFC) aus kontaminierten Böden in Nutzpflanzen (Transfer of polyfluorinated and perfluorinated chemicals (PFC) from contaminated soils to crop plants). VDLUFA-Schriftenreihe 71:727–744

Cited by

See all 155

Metadata

Authors
Riegel, M., Haist-Gulde, B., & Sacher, F.
Affiliations
DVGW - Technologiezentrum Wasser (DE)
Corresponding author
Riegel, Marcel
Venue
Environmental Sciences Europe
Published
2023-02-15
Volume
35
Issue
1
ISSN
2190-4715 (ISSN-L)
OpenAlex
W4320912988
Cited by
155
References
21
Citations by year
2026: 64 · 2025: 44 · 2024: 36 · 2023: 11
FWCI
13.37
Type
journal article
Language
en
Open access
Licence
Locations
  • Environmental Sciences Europe (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Deutsche Verein des Gas- und Wasserfaches e.V. - technisch-wissenschaftlicher Verein (DVGW)
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
Keywords
short-chain PFAS, perfluorobutanoic acid, PFPeA, perfluorohexanoic acid, activated carbon filtration, anion exchange, drinking water treatment, groundwater contamination, ethanol elution, adsorption affinity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger. https://app.cochat.ai/papers/10.1186/s12302-023-00716-5
The paper
Riegel, M., Haist-Gulde, B., & Sacher, F. (2023). Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger. Environmental Sciences Europe. https://doi.org/10.1186/s12302-023-00716-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.