Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index; none of the 13 sources its claims cite is checked for support yet.
Abstract
AbstractLaboratory tests and column tests were carried out in a waterwoks to investigate the removal of short- and long-chain PFAS using activated carbon filtration and ion exchange treatment. For all adsorbents, the sorption affinity of short-chain per- and polyfluoroalkyl carboxylic acids (PFCA) was significantly lower than that of long-chain PFAS or short-chain per- and polyfluoroalkyl sulfonic acids (PFSA). In the PFAS-polluted groundwater matrix, the short-chain PFCA PFBA and PFPeA could only be sufficiently removed with activated carbon over short run times of 6000 and 11,000 bed volumes (BV), respectively. Longer PFCA with a chain length of C6 or more were removed over longer run times.The removal of short-chain PFCA using ion exchange media could also only be achieved over relatively short run times of 5000 BV for PFBA, 10,000BV for PFPeA and 18,000 BV for PFHxA. These are sometimes significantly longer than those of activated carbon. Due to the higher material costs for ion exchange media, there are nevertheless no lower operating costs when the ion exchangers are used in single-use mode. However, ion exchangers can be regenerated and then reused which can result in economic advantages compared to activated carbon filtration. However, for the extensive regeneration, especially for the elution of the long-chain PFAS, the additional use of ethanol is needed in the process. In contrast, the short-chain PFBA and PFPeA can be extracted without organic solvent from a weakly basic ion exchanger.
Overview
CoChat Summary
TL;DR
This study compares granular activated carbon (GAC) and anion exchange (IEX) for removing short- and long-chain PFAS from drinking water, using batch isotherms and field column tests with PFAS-contaminated groundwater. Short-chain perfluoroalkyl carboxylic acids (PFCA), especially PFBA and PFPeA, broke through much earlier than long-chain PFAS, and IEX regeneration required ethanol-containing regenerants for extensive PFAS elution.
Key findings
- Sorption affinity increased with PFAS chain length and was higher for sulfonates than carboxylates. GAC order: PFOA > PFHxA > PFPeA > PFBA; IEX K6362 order: PFOS > PFHxS > PFBS ≈ PFOA > PFHpA > PFHxA > PFPeA > PFBA.
- In PFAS-contaminated groundwater, GAC-CC showed 10% breakthrough at 6000 BV for PFBA, 11,000 BV for PFPeA, 16,000 BV for PFHxA, 20,000 BV for PFHpA, and 23,000 BV for PFOA; corresponding GAC loadings were 2.4, 17, 21, 11, and 29 µg/g. IEX D5706 showed 10% breakthrough at 4000 BV for PFBA, 10,000 BV for PFPeA, 25,000 BV for PFHxA, and >50,000 BV for PFHpA and PFOA (Table 8).
- Standard regenerants (NaOH, HCl, NaCl, Na₂SO₄, Na₂CO₃) gave minor or no regeneration for PFHxA, PFHpA, and PFOA; PFPeA and PFBA were more easily extracted from WBA MP62. Complete extraction of PFCA from IEX A532E used 1 M NaCl in 45%/55% ethanol/water, and WBA D5706 regeneration was highest with 0.5 M HCl in 45% ethanol.
- In column regeneration, the fourth regeneration with 6 BV of 1 M HCl in 45% ethanol almost completely regenerated all C4–C8 PFCA; the regenerate had PFPeA, PFHxA, PFHpA, and PFOA concentrations 3500–6000 times higher than the contaminated groundwater. Separation factors with 10 BV regenerate were 100 for PFPrA, 400 for PFBA, 1000 for PFPeA, 2500 for PFHxA, and >5000 for PFHpA and PFOA.
- Single-use IEX was not more cost-effective than GAC: for PFHxA, D5706 had more than twice the adsorption capacity of GAC-CC before breakthrough, but specific consumable material costs were 20 cent/m³ versus 11 cent/m³. With regeneration, D5706 material costs were lower than GAC-CC after two adsorption/regeneration cycles for PFHpA and PFHxA, and after five cycles for PFPeA.
Methods
- Batch equilibrium experiments used five GAC types and six basic anion exchange media. GAC isotherms used demineralized water spiked with PFBA, PFPeA, PFHxA, and PFOA at 6 µg/L each, 24 h contact, and Freundlich fitting. IEX isotherms used tap water spiked with eight PFAS (PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFBS, PFHxS, PFOS) at 100 µg/L each, pH 7.0 ± 0.3, at least 60 h equilibration, and Langmuir fitting.
- Field column experiments were carried out at a waterworks in Southern Germany receiving PFAS-contaminated groundwater, primarily PFPeA at 0.74 µg/L and PFHxA at 0.62 µg/L. GAC was tested with the Granular Carbon Selection Test (GCS) and a pilot adsorber at 8 m/h; IEX pilot columns used 8 L resin, 10–25 BV/h, EBCT 2.4–6 min, and filtration velocities of 10–25 m/h.
- PFAS were analyzed by HPLC-MS/MS according to DIN 38407-42, with isotope-labelled internal standards and external calibration in tap water; solid-phase concentrations were calculated by mass balance.
Limitations
- The paper states that GCS test data should not be upscaled and should only be used for adsorbent comparison because the high filtration velocity and low bed depth produce breakthrough after around three weeks and curve shapes that differ from full-scale data.
- The paper states that the cost comparison refers solely to material costs; IEX use would also incur costs for regeneration agents, disposal or further treatment of PFAS-containing regenerate, transport, and further operation, and detailed cost estimation requires further investigations including GAC reactivation.
- Evident from the text: IEX breakthrough values are inconsistent between the abstract and Table 8/text (e.g., PFBA 5000 BV in the abstract vs 4000 BV in Table 8; PFHxA 18,000 BV in the abstract vs 25,000 BV in Table 8). Also, batch IEX experiments used tap water spiked at 100 µg/L per PFAS, much higher than the groundwater concentrations (<1 µg/L), so batch-derived affinities may not fully represent field behavior.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures












Verification
Claims the paper makes
0 Valid · 1 Not valid · 8 Not checked · 84 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“PFBA breakthrough could be observed at 5,000 BV.”
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Pilot-scale column investigations Activated carbon
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The strong base anion exchanger A532E and the weak base anion exchanger D5706 show the steepest isotherms.”
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Ion exchange
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In the PFAS-polluted groundwater matrix, the short-chain PFCA PFBA and PFPeA could only be sufficiently removed with activated carbon over short run times of 6000 and 11,000 bed volumes (BV), respectively.”
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Abstract
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The experimental investigations with IEX K6362 and several other resins (Fig. 2 and Table 6) lead to the following order of adsorption of the PFAS: PFOS > PFHxS > PFBS ≈ PFOA > PFHpA > PFHxA > PFPeA > PFBA.”
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Ion exchange
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“However, for the extensive regeneration, especially for the elution of the long-chain PFAS, the additional use of ethanol is needed in the process.”
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
58 more claims
Create a free account to see all 93 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 24
- Probably not a substantial claim. 10
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Column experiments in the field
“The first regeneration was performed using 1 M caustic soda.”
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Comparative evaluation and conclusions
“regeneration number 1:3 BV of 1 M NaCl”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Comparative evaluation and conclusions
“a complete breakthrough is observed for the short-chain PFBA at a specific throughput < 10,000 BV.”
§ Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger > Pilot-scale column investigations Activated carbon
“At a specific throughput of 11,000 BV the effluent and initial concentration were equal, i.e. c/c 0 = 1.”
Citations
Cites
Buck, R. C., Franklin, J., Berger, U., Conder, J. M., Cousins, I. T., de Voogt, P., Jensen, A. A., Kannan, K., Mabury, S. A., & van Leeuwen, S. P. (2011) · Integrated Environmental Assessment and Management · doi:10.1002/ieam.258 · Cited by 4,641
Rahman, M. F., Peldszus, S., & Anderson, W. B. (2014) · Water Research · doi:10.1016/j.watres.2013.10.045 · Cited by 1,022
McCleaf, P., Englund, S., Östlund, A., Lindegren, K., Wiberg, K., & Ahrens, L. (2017) · Water Research · doi:10.1016/j.watres.2017.04.057 · Cited by 634
A review of emerging technologies for remediation of PFASs
Ross, I., McDonough, J., Miles, J., Storch, P., Thelakkat Kochunarayanan, P., Kalve, E., Hurst, J., S. Dasgupta, S., & Burdick, J. (2018) · Remediation Journal · doi:10.1002/rem.21553 · Cited by 606 · cited 1×
“Adsorption onto granular activated carbon (GAC) is a field-proven technology for the removal of long-chain PFAS, like PFOS and PFOA, from contaminated water [14, 27].”
BackgroundNovel treatment technologies for PFAS compounds: A critical review
Kucharzyk, K. H., Darlington, R., Benotti, M., Deeb, R., & Hawley, E. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2017.08.016 · Cited by 562 · cited 1×
“Adsorption onto granular activated carbon (GAC) is a field-proven technology for the removal of long-chain PFAS, like PFOS and PFOA, from contaminated water [14, 27].”
BackgroundRemoval of perfluorinated surfactants by sorption onto granular activated carbon, zeolite and sludge
Ochoa-Herrera, V., & Sierra-Alvarez, R. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2008.04.029 · Cited by 482
Trends in the regulation of per- and polyfluoroalkyl substances (PFAS): a scoping review
Brennan, N. M., Evans, A. T., Fritz, M. K., Peak, S. A., & von Holst, H. E. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182010900 · Cited by 422
Ahrens, L., Taniyasu, S., Yeung, L. W. Y., Yamashita, N., Lam, P. K. S., & Ebinghaus, R. (2010) · Chemosphere · doi:10.1016/j.chemosphere.2010.01.045 · Cited by 418
Zaggia, A., Conte, L., Falletti, L., Fant, M., & Chiorboli, A. (2016) · Water Research · doi:10.1016/j.watres.2015.12.039 · Cited by 410
Park, H., Vecitis, C. D., Cheng, J., Choi, W., Mader, B. T., & Hoffmann, M. R. (2009) · The Journal of Physical Chemistry A · doi:10.1021/jp807116q · Cited by 305
Research works printed but not linked: 10
- Cornelsen M (2015) Neues verfahren zur entfernung von per- und polyfluorierten chemikalien aus komplex belasteten wässern (new process for removing perfluorinated and polyfluorinated chemicals from complex contaminated waters). gwf-Wasser Abwasser 9:918–925
- EC: European commission 2006 directive 2006/122/EC of the European parliament and of the council of 12 December 2006 amending for the 30th time council directive 76/769/EEC on the approximation of the laws, regulations and administrative provisions of the Member States relating to restrictions on the marketing and use of certain dangerous substances and preparations (perfluorooctane sulfonates). In: Official journal of the European Union 372/32
- Haist-Gulde B, Baldauf G (2014) Kornaktivkohlen zur Trinkwasseraufbereitung (granular activated carbons for drinking water treatment). Energie-wasser-praxis 6:50–55
- Haist-Gulde B, Baldauf G, Brauch H-J (1993) Removal of pesticides from raw waters. Water Supply 11:159–168
- Lutze H. 2013 Sulfate radical based oxidation in water treatment. PhD thesis, Universität Duisburg-Essen, Germany
- Riegel M, Sacher F, Lange FT (2017) Aufbereitungstechnische entfernung kurzkettiger perfluorierter chemikalien (PFC) durch anionenaustauscher (removal of short-chain perfluorinated chemicals (PFC) by anion exchangers). Vom Wasser 115(2):57–61
- Stockholm convention. Ninth meeting of the conference of the parties to the stockholm convention. Joint press release with the Ministry of the Environment, 14 May 2019. https://www.meti.go.jp/english/press/2019/0514_001.html
- Sontheimer H, Crittenden JC, Summers RS (1988) Activated carbon for water treatment. DVGW-Forschungstelle, Karlsruhe
- Szabo J, Hall J, Magnuson M, Panguluri S, Meiners G (2017) Treatment of perfluorinated alkyl substances in wash water using granular acitvated carbon and mixed-media, report EPA/600/R-17/175. US-EPA, Cincinnati, USA
- Trenkle A (2015) Transfer von poly- und perfluorierten Chemikalien (PFC) aus kontaminierten Böden in Nutzpflanzen (Transfer of polyfluorinated and perfluorinated chemicals (PFC) from contaminated soils to crop plants). VDLUFA-Schriftenreihe 71:727–744
Cited by
Regeneration of exhausted adsorbents after PFAS adsorption: A critical review
Vakili, M., Cagnetta, G., Deng, S., Wang, W., Gholami, Z., Gholami, F., Dastyar, W., Mojiri, A., & Blaney, L. (2024) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2024.134429 · Cited by 182
A Critical Review on PFAS Removal from Water: Removal Mechanism and Future Challenges
Amen, R., Ibrahim, A., Shafqat, W., & Hassan, E. B. (2023) · Sustainability · doi:10.3390/su152316173 · Cited by 137
Umeh, A. C., Hassan, M., Egbuatu, M., Zeng, Z., Al Amin, M., Samarasinghe, C., & Naidu, R. (2023) · Science of The Total Environment · doi:10.1016/j.scitotenv.2023.166568 · Cited by 109
Habib, Z., Song, M., Ikram, S., & Zahra, Z. (2024) · Pollutants · doi:10.3390/pollutants4010009 · Cited by 137
Chitosan Hydrogels for Water Purification Applications
Chelu, M., Musuc, A. M., Popa, M., & Moreno, J. M. C. (2023) · Gels · doi:10.3390/gels9080664 · Cited by 108
Metadata
- Authors
- Riegel, M., Haist-Gulde, B., & Sacher, F.
- Affiliations
- DVGW - Technologiezentrum Wasser (DE)
- Corresponding author
- Riegel, Marcel
- ORCID
- Riegel, Marcel
- Venue
- Environmental Sciences Europe
- Published
- 2023-02-15
- Volume
- 35
- Issue
- 1
- ISSN
- 2190-4715 (ISSN-L)
- OpenAlex
- W4320912988
- Semantic Scholar
- 337bb7d6029de41fabf1e7aa88e402ff33fcf755
- Cited by
- 155
- References
- 21
- Citations by year
- 2026: 64 · 2025: 44 · 2024: 36 · 2023: 11
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Environmental Sciences Europe (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Deutsche Verein des Gas- und Wasserfaches e.V. - technisch-wissenschaftlicher Verein (DVGW)
- Topics
- Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
- Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
- Keywords
- short-chain PFAS, perfluorobutanoic acid, PFPeA, perfluorohexanoic acid, activated carbon filtration, anion exchange, drinking water treatment, groundwater contamination, ethanol elution, adsorption affinity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger. https://app.cochat.ai/papers/10.1186/s12302-023-00716-5
- The paper
- Riegel, M., Haist-Gulde, B., & Sacher, F. (2023). Sorptive removal of short-chain perfluoroalkyl substances (PFAS) during drinking water treatment using activated carbon and anion exchanger. Environmental Sciences Europe. https://doi.org/10.1186/s12302-023-00716-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.