Intraoperative burst suppression is associated with postoperative delirium following cardiac surgery: a prospective, observational study
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Postoperative delirium (POD) occurs frequently after cardiac surgery and is associated with increased morbidity and mortality. We analysed whether perioperative bilateral BIS monitoring may detect abnormalities before the onset of POD in cardiac surgery patients. METHODS: In a prospective observational study, 81 patients undergoing cardiac surgery were included. Bilateral Bispectral Index (BIS)-monitoring was applied during the pre-, intra- and postoperative period, and BIS, EEG Asymmetry (ASYM), and Burst Suppression Ratio (BSR) were recorded. POD was diagnosed according to the Confusion Assessment Method for the Intensive Care Unit, and patients were divided into a delirium and non-delirium group. RESULTS: POD was detected in 26 patients (32%). A trend towards a lower ASYM was observed in the delirium group as compared to the non-delirium group on the preoperative day (ASYM = 48.2 ± 3.6% versus 50.0 ± 4.7%, mean ± sd, p = 0.087) as well as before induction of anaesthesia, with oral midazolam anxiolysis (median ASYM = 49.5%, IQR [47.4;51.5] versus 50.6%, IQR [49.1;54.2], p = 0.081). Delirious patients remained significantly (p = 0.018) longer in a burst suppression state intraoperatively (107 minutes, IQR [47;170] versus 44 minutes, IQR [11;120]) than non-delirious patients. Receiver operating analysis revealed burst suppression duration (area under the curve = 0.73, p = 0.001) and BSR (AUC = 0.68, p = 0.009) as predictors of POD. CONCLUSIONS: Intraoperative assessment of BSR may identify patients at risk of POD and should be investigated in further studies. So far it remains unknown whether there is a causal relationship or rather an association between intraoperative burst suppression and the development of POD. TRIAL REGISTRATION: clinicaltrials.gov NCT01048775.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sessler, C. N., Gosnell, M. S., Grap, M. J., Brophy, G. M., O'Neal, P. V., Keane, K. A., Tesoro, E. P., & Elswick, R. K. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2107138 · Cited by 3,695 · cited 1×
“Depending on their Richmond Agitation-Sedation Score (RASS), [22] delirious patients were subgrouped as either hypoactive (RASS ≤ 0) or hyperactive (RASS > 0).”
MethodEly, E. W., Inouye, S. K., Bernard, G. R., Gordon, S., Francis, J., May, L., Truman, B., Speroff, T., Gautam, S., Margolin, R., et al. (2001) · JAMA · doi:10.1001/jama.286.21.2703 · Cited by 3,210 · cited 3×
“Monitoring for delirium and outcome Postoperatively, patients were monitored for the occurrence of POD using the flowsheet version of the Confusion Assessment Method for Intensive Care Units (CAM-ICUFlowsheet), which is explained in more detail elsewhere [20,21].”
MethodDelirium as a Predictor of Mortality in Mechanically Ventilated Patients in the Intensive Care Unit
Ely, E. W. (2004) · JAMA · doi:10.1001/jama.291.14.1753 · Cited by 3,073 · cited 1×
“an increased morbidity and mortality [5-7].”
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869 · cited 1×
“Presumably, such lateralization phenomena might only be detected applying dedicated techniques such as Low Resolution Electromagnetic Tomography [25] or intracranial EEG recordings, but not using a single or dual channel EEG analyzer such as the BIS monitor, which analyses superficial and local electrical activity per…”
Method
Cited by
Aldecoa, C., Bettelli, G., Bilotta, F., Sanders, R. D., Audisio, R., Borozdina, A., Cherubini, A., Jones, C., Kehlet, H., MacLullich, A., et al. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000594 · Cited by 1,102
Postoperative delirium: perioperative assessment, risk reduction, and management
Jin, Z., Hu, J., & Ma, D. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.06.063 · Cited by 697
Hughes, C. G., Boncyk, C. S., Culley, D. J., Fleisher, L. A., Leung, J. M., McDonagh, D. L., Gan, T. J., McEvoy, M. D., Miller, T. E., & Workgroup, F. T. P. Q. I. (. 6. (2020) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004641 · Cited by 391
Aldecoa, C., Bettelli, G., Bilotta, F., Sanders, R. D., Aceto, P., Audisio, R., Cherubini, A., Cunningham, C., Dabrowski, W., Forookhi, A., et al. (2024) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001876 · Cited by 356
Intraoperative Electroencephalogram Suppression Predicts Postoperative Delirium
Fritz, B. A., Kalarickal, P. L., Maybrier, H. R., Muench, M. R., Dearth, D., Chen, Y., Escallier, K. E., Ben Abdallah, A., Lin, N., & Avidan, M. S. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000989 · Cited by 333
Metadata
- Authors
- Soehle, M., Dittmann, A., Ellerkmann, R. K., Baumgarten, G., Putensen, C., & Guenther, U.
- Venue
- BMC Anesthesiology
- Published
- 2015-04-28
- Volume
- 15
- Issue
- 1
- Pages
- 61-61
- ISSN
- 1471-2253 (ISSN-L)
- OpenAlex
- W2067957582
- Cited by
- 239
- References
- 4
- FWCI
- 10.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.