Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 36 of the 40 references it cites were found in a registry or an index; 10 of the 12 sources its claims cite were checked for support.

Medical image diagnosis based on adaptive Hybrid Quantum CNN

Open access

Published version of a preprint

Abstract

Hybrid quantum systems have shown promise in image classification by combining the strengths of both classical and quantum algorithms. These systems leverage the parallel processing power of quantum computers to perform complex computations while utilizing classical algorithms to handle the vast amounts of data involved in imaging. The hybrid approach is intended to improve accuracy and speed compared to traditional classical methods. Further research and development in this area can revolutionize the way medical images are classified and help improve patient diagnosis and treatment. The use of Conventional Neural Networks (CNN) for the classification and diagnosis of medical images using big datasets requires, in most cases, the use of special high-performance computing machines, which are very expensive and hard to access by most researchers. A new form of Machine Learning (ML), Quantum machine learning (QML), is being introduced as an emerging strategy to overcome this problem. A hybrid quantum-classical CNN uses both quantum and classical convolution layers designed to use a parameterized quantum circuit. This means that the computing model utilizes a quantum circuits approach to construct QML algorithms, which are then used to transform the quantum state to extract image hidden features. This computational acceleration is expected to achieve better algorithm performance than classical CNNs. This study intends to evaluate the performance of a Hybrid Quantum CNN (HQCNN) against a conventional CNN. This is followed by some optimizer modifications for both proposed and classical CNN methods to investigate the possible further improvement of their performance. The optimizer modification is based on forcing the optimizer to be directly adaptive to model accuracy. The optimizer adaptiveness is based on the development of an optimizer with a loss base adaptive momentum. Several algorithms are developed to achieve the above-mentioned goals, including CNN, QCNN, CNN with the adaptive optimizer, and QCNN with the Adaptive optimizer. The four algorithms are tested against a Kaggle brain dataset containing over 7000 samples. The test results show the hybrid quantum circuit algorithm outperformed the conventional CNN algorithm. The performance of both algorithms was further improved by using a fully adaptive SGD optimizer.

Overview

CoChat Summary

## TL;DR

The paper proposes a hybrid quantum-classical convolutional neural network (HQCNN) for brain tumor image classification and compares it with a conventional CNN on two MRI datasets. It reports that HQCNN converges faster and, with a fully adaptive SGD optimizer, reaches 98.07% accuracy within 70 epochs, outperforming the CNN.

## Key findings

  • On the Kaggle Brain Tumor MRI dataset, the study reports 98.07% accuracy for the HQCNN within 70 epochs, while the conventional CNN needed 100 epochs for nearly the same accuracy level.
  • The results section says the quantum circuit model reached the same accuracy as the CNN within 70 epochs, and the HQCNN reached it within 63 epochs.
  • The paper reports that the fully adaptive SGD optimizer improved both the classical CNN and the quantum circuit model, improving convergence speed.
  • Statistical testing in the results reports p = 0.0027 for a paired t-test, which the paper interprets as a statistically significant performance difference; it also reports Cohen’s d = 0.184 at epoch 1 and Cohen’s d = 2.385 at epoch 20.

## Methods

  • The study compares CNN, HQCNN, and versions with a fully adaptive SGD optimizer; it frames the HQCNN as combining a quantum convolutional layer, quantum pooling, and a classical fully connected layer.
  • Two datasets were used: the Kaggle Brain Tumor MRI dataset with 7,023 images across 4 classes and the REM-BRANDT dataset with 106,541 DICOM images after preprocessing, also split into 4 classes.
  • Model structure was optimized using Genetic Algorithms (GA); performance was evaluated with accuracy, recall, precision, and F1 score, along with t-tests and confidence intervals.

## Limitations

  • The paper explicitly says further investigation is warranted to assess performance on other types of data.
  • It also states future work is needed to study robustness against adversarial attacks.
  • Evident from the text: several sections in the provided record are incomplete or truncated, and some equation references and figures/tables are mentioned but not fully shown; this limits what can be verified from the text alone.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s12880-023-01084-5

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Conventional CNN structure
Fig. 1 Conventional CNN structureCC BY · PubMed Central
Fig. 2 MAX pooling operation
Fig. 2 MAX pooling operationCC BY · PubMed Central
Fig. 3 Schematic of PQC
Fig. 3 Schematic of PQCCC BY · PubMed Central
Fig. 4 bock structure of HQCNN
Fig. 4 bock structure of HQCNNCC BY · PubMed Central
Fig. 5 Single quantum layer image processing scheme
Fig. 5 Single quantum layer image processing schemeCC BY · PubMed Central
Fig. 6 Embedding a 2 × 2 image region into a quantum circuit
Fig. 6 Embedding a 2 × 2 image region into a quantum circuitCC BY · PubMed Central
Fig. 7 4 qubits with parameterized rotation gates
Fig. 7 4 qubits with parameterized rotation gatesCC BY · PubMed Central
Fig. 8 Sample from Kaggle brain dataset
Fig. 8 Sample from Kaggle brain datasetCC BY · PubMed Central
Fig. 9 Samples from the REMBRANDT dataset
Fig. 9 Samples from the REMBRANDT datasetCC BY · PubMed Central
Fig. 10 Convergence curve of tune process of HQCNN, CNN, and fully Adaptive HQCNN
Fig. 10 Convergence curve of tune process of HQCNN, CNN, and fully Adaptive HQCNNCC BY · PubMed Central
Fig. 11 Validation Accuracy of the classical CNN algorithm and the proposed HQCNN Algorithm
Fig. 11 Validation Accuracy of the classical CNN algorithm and the proposed HQCNN AlgorithmCC BY · PubMed Central
Fig. 12 Plot of the P-value of t-test on the performance accuracy of both the classical and HQCNN
Fig. 12 Plot of the P-value of t-test on the performance accuracy of both the classical and HQCNNCC BY · PubMed Central
Fig. 13 The effect size of the Cohens d for classical CNN and HQCNN
Fig. 13 The effect size of the Cohens d for classical CNN and HQCNNCC BY · PubMed Central
Fig. 14 training speed per Epochs using CPU and GPU for CNN and HQCNN models
Fig. 14 training speed per Epochs using CPU and GPU for CNN and HQCNN modelsCC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 2 Not valid · 1 Not checked · 44 Own results and interpretations

23 more claims

Create a free account to see all 48 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 9
  • It may state two separate claims as one. 10
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 40 references

Cited by

See all 97

Metadata

Authors
Ajlouni, N., Özyavaş, A., Takaoğlu, M., Takaoğlu, F., & Ajlouni, F.
Affiliations
  • TUBITAK BILGEM (TR)
  • Atlas Üniversitesi (TR)
  • Türkiye Bilimsel ve Teknolojik Araştırma Kurumu (TR)
Corresponding author
Ajlouni, Naim
Venue
BMC Medical Imaging
Published
2023-09-14
Volume
23
Issue
1
Pages
126-126
ISSN
1471-2342 (ISSN-L)
OpenAlex
W4386746261
Cited by
97
References
40
Citations by year
2026: 53 · 2025: 29 · 2024: 15
FWCI
9.12
Type
journal article
Language
en
Open access
Licence
Locations
  • BMC Medical Imaging (publishedVersion, cc-by)
  • Research Square (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
quantum machine learning, medical image classification, brain MRI classification, adaptive optimization algorithm, adaptive momentum, variational quantum circuits, quantum convolutional neural networks, diagnostic imaging
MeSH terms
Machine Learning, Algorithms, Brain, Humans, Motion, Neural Networks, Computer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medical image diagnosis based on adaptive Hybrid Quantum CNN. https://app.cochat.ai/papers/10.1186/s12880-023-01084-5
The paper
Ajlouni, N., Özyavaş, A., Takaoğlu, M., Takaoğlu, F., & Ajlouni, F. (2023). Medical image diagnosis based on adaptive Hybrid Quantum CNN. BMC Medical Imaging. https://doi.org/10.1186/s12880-023-01084-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.